SubstiTUBE® Value – ST8-HV5

www.osram.com
SubstiTUBE® Value – ST8-HV5
Datasheet
Innovative LED-lamp, easy and safe to use in CCG
installations as direct retrofit. Energy saving potential of up to
66% by replacing 1.5 m T8 fluorescent tubes.
Instant 100% light without flickering. No mercury.
Applicable in warehouses, cold storage, supply rooms,
corridors, industry, stairways, garages, indirect illumination
etc; for applications with high operating hours.
Technical operating data
Product
Color
Colortemp. Lum. Flux
[K]
[lm]
Cool
Daylight
6500 K
ST8-HV5-200-840
Cool White
4000 K
2000
ST8-HV5-180-830
Warm White
3000 K
1800
ST8-HV5-200-865
Voltage [V] /
Frequency [Hz]
Input current [A]
Power
[W]
RadianceAngle [°]
230 V*
220 - 240 V
50 / 60 Hz
0,01 A
22 W
150°
2000
All Data are related to the entire lamp. Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters
can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical
data.
* Rated voltage
Technical Features
 LED lamp in T8 shape with G13 socket
 Powerfactor > 0.9
 Length excl. pins: 1500 mm
 Up to 30,000 h lifetime
 Weight: 361g
 Switching cycles > 200.000
 For operation at magnetic ballast
 Color Rendering Index (CRI) > 80
 Direct Retrofit for CCG luminaires;
replacement of lamp and included starter
 Overpower, overheat and short circuit
protected
 No rewiring necessary at CCG
 High color homogeneity
 Extremely robust due to polycarbonate
body
 RoHS-conformity, no mercury
 Fully integrated ECG complies to relevant
standards
ST8-HV5 – May 2014
 Not for operation with ECG, not
dimmable
 Energy Efficiency Class: A
Page 1 of 5
Minimum / Maximum ratings
Operating temperature
Tc
Storage temperature
Ts
Ambient temperature
Ta
-20° … 75°C
-20° ... 80°C
-20° ... 45°C
ST8-HV5
Drawings
Product
l
d
ST8-HV5
1500 mm
27,5 mm
ST8-HV5 – May 2014
Page 2 of 5
Safety and Application notes
 The SubstiTUBE® Value must not be damaged or operated in a damaged condition.
 When operating with CCG, the included „SubstiTUBE® Start“ has to be inserted as well. If
the conventional starter is not replaced the SubstiTUBE® Value will start blinking. Switch
off immediately, the SubstiTUBE® Value can be damaged!
Lamp suitable for 50 Hz
or 60 Hz operation
Lamp not suitable for high
frequency operation
Lamp not suitable for
emergency operation
 Do not use SubstiTUBE® Value in luminaires which do not have any starter or when the
starter cannot be replaced.
 Not usable in luminaires with serial lamp connection i.e. more than one tube at one
magnetic ballast (tandem circuitry).
 The SubstiTUBE® Value emits light only with a limited angle, not like a fluorescent tube
with 360°output.
 Due to the characteristic light distribution of the SubstiTUBE® Value, the resulting luminaire
light characteristic is likely to change. It is not guaranteed that e.g. standards for lighting at
working places will be complied to after replacement. A photometric check of the
installation is recommended.
 The effective energy savings depend on the efficiency of the luminaire setup to be
replaced and should be considered individually in each case.
Particularly magnetic ballast losses are reduced to ohmic losses and are normally only
about 1 W.

The SubstiTUBE® Value is protected according to IP20. Applications with
external risk of moisture and dust can be served with an adequately protected
luminaire.
 SubstiTUBE® Value may also be driven directly on line voltage. In order to grant a safe
operation mode please refer to the installation instructions for further information.
 Photobiological Safety of lamps and lamp systems according to IEC 62471.
Risk Group: Exempt
ST8-HV5 – May 2014
Page 3 of 5
Installation Instructions for CGG
 Make sure that the supply voltage is disconnected.
 Carefully remove the fluorescent tube and starter according to the lamp holder type.
 Insert SubstiTUBE® Value and SubstiTUBE® Start properly.
Below an example for typical lamp holder types is described
 Turn the conventional lamp 90° degrees and take it out of the socket.
 Remove the conventional starter by turning it.
 Insert and latch the SubstiTUBE® Start into starter socket.
 Insert SubstiTUBE® Value into socket and locate into position by turning 90°.
 Check light emission direction.
Circuit diagram of a retrofitted CCG luminaire
ST8-HV5 – May 2014
Page 4 of 5
Ordering guide
Product name
Light color
EAN*
ST8-HV5-200-865
Cool Daylight / 6500 K
4052899922365
ST8-HV5-200-840
Cool White / 4000 K
4052899922358
ST8-HV5-180-830
Warm White / 3000 K
4052899922341
S-Unit**
4x1
* EAN: Ordering number per single module
** S-Unit: Lamps per shipping unit
Sales and Technical Support
OSRAM GmbH
Sales and technical support is given by the
local OSRAM subsidiaries.
On our world wide homepage all OSRAM
subsidiaries are listed with complete
address and phone numbers.
Marcel-Breuer-Strasse 6
D - 80807 München Germany
www.osram.com
+49 (0)89 6213-0
Further Information
 Downloads: Eulumdat /IES files, CE declaration
ST8-HV5 – May 2014
Page 5 of 5
www.osram.com/SubstiTUBE