Technical operating data
Product
Color
Colortemp. Lum. Flux
[K]
[lm]
Cool
Daylight
6500 K
ST8-HA2-120-840
Cool White
4000 K
1200
ST8-HA2-108-830
Warm White
3000 K
1080
ST8-HA2-120-865
Voltage [V] /
Frequency [Hz]
Input current [A]
Power
[W]
RadianceAngle [°]
230 V*
200 - 240 V
50 / 60 Hz
0.01 A
11 W
160°
1200
All Data are related to the entire lamp. Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters
can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical
data.
* Rated voltage
Technical Features
 LED lamp in T8 shape with G13 socket
 Powerfactor > 0.9
 Length excl. pins: 590 mm
 Up to 50,000 h lifetime
 Weight: <500g
 Switching cycles > 200.000
 For operation at magnetic ballast
 Color Rendering Index (CRI) > 80
 Direct Retrofit for CCG luminaires;
replacement of lamp and included starter
 Overpower, overheat and short circuit
protected
 No rewiring necessary at CCG
 High color homogeneity
 Extremely robust due to polycarbonate
body
 RoHS-conformity, no mercury
 Fully integrated ECG complies to relevant
standards
ST8-HA2 – March 2014
 Not for operation with ECG, not
dimmable
 Energy Efficiency Class: A+
Page 1 of 5
Minimum / Maximum ratings
ST8-HA2
Operating temperature
Tc
Storage temperature
Ts
Ambient temperature
Ta
-20° … 75°C
-20° ... 80°C
-20° ... 45°C
Drawings
Product
l
d1
d
ST8-HA2
590 mm
26 mm
27,5 mm
ST8-HA2 – March 2014
Page 2 of 5
Safety and Application notes
 The SubstiTUBE® Advanced must not be damaged or operated in a damaged condition.
 When operating with CCG, the included „SubstiTUBE® Start“ has to be inserted as well. If
the conventional starter is not replaced the SubstiTUBE® Advanced will start blinking.
Switch off immediately, the SubstiTUBE® Advanced can be damaged!
Lamp suitable for 50 Hz
or 60 Hz operation
Lamp not suitable for high
frequency operation
Lamp not suitable for
emergency operation
 Do not use SubstiTUBE® Advanced in luminaires which do not have any starter or when
the starter cannot be replaced.
 Not usable in luminaires with serial lamp connection i.e. more than one tube at one
magnetic ballast (tandem circuitry).
 The SubstiTUBE® Advanced emits light only with a limited angle, not like a fluorescent
tube with 360°output.
 Due to the characteristic light distribution of the SubstiTUBE® Advanced, the resulting
luminaire light characteristic is likely to change. It is not guaranteed that e.g. standards for
lighting at working places will be complied to after replacement. A photometric check of the
installation is recommended.
 The effective energy savings depend on the efficiency of the luminaire setup to be
replaced and should be considered individually in each case.
Particularly magnetic ballast losses are reduced to ohmic losses and are normally only
about 1 W.

The SubstiTUBE® Value is protected according to IP20. Applications with
external risk of moisture and dust can be served with an adequately protected
luminaire.
 SubstiTUBE® Advanced may also be driven directly on line voltage. In order to grant a
safe operation mode please refer to the installation instructions for further information.
 Maximum amount of SubstiTUBE® Advanced on one circuit breaker
Circuit breaker 10 A (B type)
Circuit breaker 16 A (B type)
//
//
//
//
//
//
CCG
CCG incl. comp. cap.
Direct mains
CCG
CCG incl. comp. cap.
Direct mains
//
//
//
//
//
//
132
53
139
212
85
222
 Photobiological Safety of lamps and lamp systems according to IEC 62471.
Risk Group: Exempt
ST8-HA2 – March 2014
Page 3 of 5
Installation Instructions for CGG
 Make sure that the supply voltage is disconnected.
 Carefully remove the fluorescent tube and starter according to the lamp holder type.
 Insert SubstiTUBE® Advanced and SubstiTUBE® Start properly.
Below an example for typical lamp holder types is described
 Turn the conventional lamp 90° degrees and take it out of the socket.
 Remove the conventional starter by turning it.
 Insert and latch the SubstiTUBE® Start into starter socket.
 Insert SubstiTUBE® Advanced into socket and locate into position by turning 90°.
 Check light emission direction.
Circuit diagram of a retrofitted CCG luminaire
ST8-HA2 – March 2014
Page 4 of 5
Ordering guide
Product name
Light color
EAN*
ST8-HA2-120-865
Cool Daylight / 6500 K
4052899922129
ST8-HA2-120-840
Cool White / 4000 K
4052899922112
ST8-HA2-108-830
Warm White / 3000 K
4052899922105
S-Unit**
25 x 1
* EAN: Ordering number per single module
** S-Unit: Lamps per shipping unit
Sales and Technical Support
OSRAM GmbH
Sales and technical support is given by the
local OSRAM subsidiaries.
On our world wide homepage all OSRAM
subsidiaries are listed with complete
address and phone numbers.
Marcel-Breuer-Strasse 6
D - 80807 München Germany
www.osram.de
+49 (0)89 6213-0
Further Information
 Downloads: Eulumdat /IES files, CE declaration
ST8-HA2 – March 2014
Page 5 of 5
www.osram.com/SubstiTUBE