Moore 345 XTC ® Critical Transmitter FEATURES & BENEFITS Only certified Critical Transmitter provides unmatched capability at the lowest risk XTC Transmitters - Critical Pressure TÜV and other hazardous location certifications accommodate installation in high availability and safety pressure measurement applications Hardware and software redundancy (shown below) reduce overall costs by allowing a single Critical Transmitter to be installed where two conventional transmitters are usually installed or two Critical instead of three conventional Comprehensive self-checking system and primary and secondary current sources (shown below) ensure accurate and safe fault indication Silicon-based MycroSENSORTM provides exceptional performance Complete loop integrity via output checking and verification provide increased system availability Rotatable NEMA 4X/6P, IP66/68 housing and rotatable display (shown on the next page) delivers long, trouble-free operation and maximum flexibility in mounting options SmartDisplayTM in engineering units affords greater operator understanding Dual Element MycroSENSOR Detects opens & shorts in all sensor signals DESCRIPTION The Moore XTC Critical Transmitter is the first TÜV-certified pressure transmitter for high availability and safety applications. It achieves this unique distinction via hardware and software redundancy, a comprehensive self-checking system, and primary and secondary current sources to ensure safe fault indication if a failure occurs. These features allow a single Critical Transmitter to be installed where two conventional transmitters are usually installed in a critical application (or two critical instead of three conventional). Thus, the XTC Critical Transmitter minimizes total cost ownership via reduced installation and maintenance expenses. ASIC uP Linearization & Compensation A/D Output 1 Comparator Diagnostic Circuit 94 Moore Process Automation Solutions D/A Output 2 www.moore-solutions.com Verify Out The transmitter carries all standard hazardous location XTC certifications, plus functional safety approval from Germany’s TÜV organization. TÜV is the only international agency that approves safety systems and instrumentation design for avoidance and control of errors, faults, and human mistakes. It rates equipment for requirement class levels (AKs) to specify the amount of safety risk reduction required by a particular application. TÜV AK levels range from a 0 (no safety provisions required) to an 8 (most dangerous processes); these are roughly parallel to ISA S84.01 safety integrity levels (SILs) 1-4. TÜV AK levels compare to S84’s SIL levels as follows: AK 1-3 to SIL 1 AK 5-6 to SIL 3 AK 7-8 to SIL 4 Moreover, the XTC Critical Transmitter follows techniques proven in the XTC family of transmitters (shown below). These features include the silicon-based dual element capacitive pressure MycroSENSOR featuring a sense and reference capacitor, which is mounted in the XTC’s hermetically sealed pressure capsule. As such, the Critical Transmitter delivers high performance and stability with superior reliability and minimal maintenance. A single Critical Transmitter is approved to AK4, and two working in parallel are approved to AK6, making the Critical Transmitter the only TÜV approved pressure transmitter on the market today. Unique Features of the XTC XTC Transmitters - Critical Pressure AK 4 to SIL 2 As shown on the previous page, separate processors verify the output of a dual element silicon sensor and use two diverse floating point routines to compute the transmitter output level. If the computed output levels differ, the transmitter output is fixed at a fail-safe level. The output is also fixed at the fail-safe level if the processor detects a difference in the actual output current as compared to the computed current. This architecture is unique to the XTC Critical Transmitter. H Americas +1 215 646 7400 ext. 6613 Asia Pacific +65 299 6051 Europe +44 1935 706262 95 MODELS Model 345D Differential Pressure Transmitter Spans from 0.2" H 2O to 450 PSID (0.05 to 3100 KPA) Standard Hastelloy-C diaphragms and 316SS wetted parts (Ranges D & F) 1/4" NPTF or 1/2" NPTF process connection XTC Transmitters - Critical Pressure Use in differential pressure, level, and flow applications Model 345A/G Absolute or Gauge Pressure Transmitter 10" H2O Abs to 450 PSIA (2.5 to 3100 KPA abs) 10" H2O to 5500 PSIG (2.5 to 37920 KPA) Standard Hastelloy-C diaphragms and 316SS wetted parts 1/2" NPTF process connection Use in pressure applications Model 345F Flanged Level Transmitter 10" H2O to 450 PSI (2.5 to 3100 KPA) Standard 316SS diaphragms and wetted parts Standard ANSI and DIN flanges Use in level and flanged pressure applications 96 Moore Process Automation Solutions www.moore-solutions.com PROCESS CONNECTIONS Model 345 Transmitter with Tantalum Diaphragms Available in DP, GP, and AP configurations Use in harsh process fluids XTC Transmitters - Critical Pressure Model 345 Transmitter with Remote Diaphragm Seals Available in various materials and process connections including threaded, flanged, weld-in, and sanitary Model 345D Differential Pressure Transmitter with Integral Orifice Assemblies Six integral orifice sizes 316 SS construction 1/2" NPTF process connection “Wet” calibrations available Use in low-flow applications Model 345D Differential Pressure Transmitter with Integral 3-Valve Manifold Factory mounted 316SS or CS construction Americas +1 215 646 7400 ext. 6613 Asia Pacific +65 299 6051 Europe +44 1935 706262 97 SPECIFICATIONS PERFORMANCE SPECIFICATIONS XTC Transmitters - Critical Pressure Reference conditions: Zero-based, positive spans, ambient temperature 23ºC, D/A trim values equal to span end points, Silicone fill, standard diaphragms, 1 second damping. Accuracy1,2 Analog Output Range A: ±0.2% of calibrated span for spans from 1:1 to 2:1 of URL ±(0.174 + 0.013[URL/Span]) % of calibrated span for spans from 2:1 to 25:1 of URL Range B: ± 0.1% of calibrated span for spans from 1:1 to 2.5:1 of URL ± (0.043 + 0.0228 [URL/span]) % of calibrated span for spans from 2.5:1 to 20:1 of URL Range D, F, G: ±0.1% of calibrated span for spans from 1:1 to 10:1 of URL ±(0.028 + 0.0072 [URL/span]) % calibrated span for spans from 10:1 to 45:1 of URL Digital Output Range D, F, G: ± 0.075% of Reading or 0.015% of URL, whichever is greater Sterling Units: ± 0.035 % of Reading or 0.006% of URL, whichever is greater Ambient Temperature Effect Models 345A, 345G, 345D Ranges A-B: ±(0.175% URL + 0.075% span) per 28ºC (50o F) Ranges D-G: ±(0.075% URL + 0.075% span) per 28ºC (50o F) Model 345F Ranges D-F2: ±(0.075% URL + 0.075% span + 1.5 "H2O) per 28ºC (50ºF) Stability Zero Stability: Range A: ±0.1% of URL for 6 months Ranges B-G: ±0.1% of URL for 12 months Span Stability: No Measurable Span Drift Humidity 0-100% relative humidity, non-condensing Vibration Effect Less than ±0.05% of maximum span per G for 0 to 60 Hz in any axis up to 2 Gs max. Power Supply Effect Less than 0.005% of output span per volt EMI/RFI Susceptibility Less than 0.25% of max. span at 30 V/m, 30 MHz - 1 GHz ESD Susceptibility IEC severity level 4, 15 kV Static Pressure Effect (340D) Range Span Error Correctable To:4 B 0.2% per 100psi D 0.2% per 1000psi F 0.2% per 1000psi NOTES: (1) Accuracy includes the effects of linearity, hysteresis and repeatability. (2) Specifications for 3" & 4" flange size only. For smaller flange sizes, consult Moore. (3) Limit to 85ºC (185ºF) in vacuum service. (4) Zero effect eliminated at operating pressure. Temperature Limits Sensor Assembly3: Silicon: -40 to 125ºC (-40 to 257ºF) Inert Fill: 0 to 85ºC (32 to 185ºF) Paratherm: -20 to 125ºC (-4 to 257ºF) Electronics: -40 to 85ºC (-40 to 185ºF) 98 Moore Process Automation Solutions www.moore-solutions.com FUNCTIONAL SPECIFICATIONS Range and Sensor Limits Model 345A, 345D, 345F, 345G Range Min. Span 345A 345D LRL/URL A 0.20" (.05KPA) NA -2/5" (5/1.25KPA) NA NA B 0.75" (0.185KPA) NA -15/15" (-3.7/3.7KPA) NA NA D 10" (2.5KPA) 0/450" (0/112.5KPAabs) -450/450" (-112.5/112.5KPA) -450/450" (-112.5/112.5KPA) -407/450" (-101/112.5KPA) F 12.6psi (87KPA) 0/450psia (0/3045KPAabs) -150/450psi (-689/3100KPA) -150/450psi (-689/3100KPA) -14.7/450psig (-101/3100KPA) G 300psi (2068KPA) NA NA 0/5500psig (0/37920KPA) 345F Zero Elevation and Suppression The range may be set anywhere between the LRL and URL of the transmitter, as long as the calibrated span does not exceed the minimum allowable span (see Range table). Zero and span in the XTC are non-interactive. 1600 Electronic Damping (Digital Filter) Adjustable between 0 and 30 seconds Transmitter Outputs Each transmitter has: LOOP RESISTANCE (OHMS) Analog, Two-Wire 4-20mA Digital, HART Communications Optional Transient Suppressor 700 OPERATING REGION 250 0 10 15 24 Power Supply Requirements Minimum Terminal to Terminal Compliance Voltage: +10 Vdc Maximum Terminal to Terminal Voltage: +42 Vdc Maximum Load: RL = 50º (Supply Voltage) - 500 Ohms1 Maximum Working Pressure2 Range 345A 345D 345G 345F A NA +/-60 psi 3 (+/-413KPA) NA NA B NA +/-100 psi3 (+/-689KPA) NA NA D 250psi (1.72MPA) +/-4000 psi (+/-27.6MPA) 250 psi(1.72MPA) Per Flange F 1500psi (10.3MPA) +/-4000 psi (+/-27.6MPA) 1500 psi(10.3MPA) Per Flange G NA 9,000 psi(6SS only 62.0MPA) NA NA 42 POWER SUPPLY (Vdc) XTC Transmitters - Critical Pressure NA 345G NOTES: (1) To ensure digital communications, HART requires the loop resistance to remain between 250 and 1100 Ohms. HART also imposes the following requirements on the loop power supply: Ripple: 0.2 Vp-p, 47-125 Hz Noise: 0.6 mV RMS maximum Impedance: 10 Ohms maximum Americas +1 215 646 7400 ext. 6613 (2) The Maximum Working Pressure (MWP) is defined as the maximum pressure that can be applied to the cell without damage, static, or otherwise. (3) 345D Range A and Range B sensors have a body rating of +/-4000 psi; however, no over pressure protection is employed in these units, thereby limiting the MWP to +/- 100 psi. Asia Pacific +65 299 6051 Europe +44 1935 706262 99 Flange Rating XTC Transmitters - Critical Pressure Standard ANSI ANSI DIN DIN Class Carbon Steel Rating Stainless Steel Rating 150# 285 psi 1 275 psi 1 300# 740 psi1 720 psi 1 PN 10/16 16 bar2 16 bar2 2 PN 25/40 40 bar 40 bar2 Surge Protection (with optional Transient Suppressor) Maximum clamping voltage (either loop terminal to enclosure) DC: 68V 100 kV per microsecond AC surge: 70V peak 1000 kV per microsecond AC surge: 120V peak Transient surge current Up to 5000 amp for 20 microseconds, repeated strikes Turn-On Time The transmitter will begin operating within 5 seconds after power is applied. The transmitter will perform within specifications within 60 seconds after power is applied. Local Indication Optional 4 1/2 Digit SmartDisplay MECHANICAL SPECIFICATIONS Dimensions See Installation Drawings (Pages115-117) Weight3 345A/G:4 4 lbs/1.8 kg 345D: 7 lbs/3.2 kg 345F: 20 lbs/9.1 kg Electronics Housing Epoxy Powder Coated, Low Copper Cast Aluminum 316 SS (optional) NEMA 4X/6P (IP66/68) (2) 1/2" -14 NPTF Electrical Conduit Entrances (M20 x 1.5 optional) Process Wetted Parts Various Materials Available NACE MR0175 compliant with options as noted in the model number breakdown. Process Connections Model 345A/G5 (1) 1/2" NPTF, no vent/drain (External block and bleed may be purchased separately) Model 345D (2) 1/4" NPTF with vent/drains (1/2" NPTF with optional process adapters) Model 345F High Pressure Side: Per flange size and rating selected Low Pressure Side: 1/4" NPTF with vent/drain (1/2" NPTF with process adapter provided) Hazardous Area Classification/Approvals6 TÜV Approvals (Standard): Single Transmitter: AK4 Two Transmitters: AK6 European Community Approved ABS Type approved FM/CSA Approval: Intrinsically Safe: Class I, Div. 1, Groups A, B, C, & D Class II, Div. 1, Groups E, F, & G Class III, Div. 1 Explosion Proof: Class I, Div. 1, Groups B, C, & D Class II, Div. 1, Groups E, F, & G Class III, Div. 1 Non-Incendive: Class I, Div. 2, Groups A, B, C, & D CENELEC Approval: Intrinsically Safe: EEx ia IIC T6, T5, T4 Explosion Proof: EEx d [ia] ia, IIC T47 BASEEFA Approval: Non-Incendive: Exn IIC T6 SAA Approval: Intrinsically Safe: Ex ia IIC T6 Explosion Proof: Ex d IIB T6 Non-Incendive: Ex n DIP IIC T6 NOTES: (1) At 100ºF (38ºC), the rating decreases with increasing temperature. (2) At 120ºC, the rating decreases with increasing temperature. (3) Weights approximate. (4) 345A/G with tantalum diaphragm: 7 lbs. (5) 345A/G Transmitters with tantalum diaphragms are differential style units. Process connections are similar to 345D. See drawings. (6) Consult Moore for information on additional approvals. (7) Consult Moore for information on special power requirements for EExd models. 100 Moore Process Automation Solutions www.moore-solutions.com MODEL NUMBER Critical Absolute Pressure 345A F B H AA B 5 N N 1 3 XTC Transmitters - Critical Pressure 345A Critical Absolute Pressure Transmitter Input Range: Span Limits, Min/Max D 10/450" H2O abs (2.5/112.5 KPA abs) F 12.6/450 psia (87/3100 KPA abs) Output B 4-20 mAdc with HART Protocol 1 C 4-20 mAdc with HART Protocol & Integral Transient Suppressor D Spare Capsule Process Diaphragm H Hastelloy C-2761 S 316L SS B Hastelloy C-276 with 1 Remote Seal (Specify AA for Body Parts) Body Parts Wetted Process Connection AA 316SS 1/2" NPT1 BA Hastelloy-C276 1/2" NPT Fill Fluid B Silicone DC2001 C Inert D Paratherm Output Indicator 5 4-1/2 Digit Digital SmartDisplay N Not Required5 Standard Options X Oxygen Cleaned Y Special Features4 N Not Required 5 Mounting Bracket 1 2" Pipe Mount Bracket with SS Hardware 2 Universal Bracket 3 2" Pipe Mount 316SS Bracket N Not Required5 Housing 1 Aluminum 1/2" - 14 NPT1 2 Aluminum M20 x 1.5 6 3 316 SS 1/2" - 14 NPT 4 316 SS M20 x 1.5 N Not Required 5 Hazardous Area Classification (TÜV Approval Standard) 2 CSA/CRN 3 FM/CSA All1 M CENELEC EEx d [ia] ia13 R SAA All & ABS Type Approved13 L CENELEC EExia & BASEEFA TFX N N Non-Approved 5 W FM/CSA All & ABS Type Approved Sample Model Number See notes on page 105. Americas +1 215 646 7400 ext. 6613 Asia Pacific +65 299 6051 Europe +44 1935 706262 101 XTC Transmitters - Critical Pressure Critical Differential Pressure 345D Critical Differential Pressure Transmitter Input Range: Span Limits, Min/Max A 0.2/5 "H2O (0.05/1.25 KPA)10 (Remote seals not available with this range.) B 0.75/15 "H 2O (0.185/3.7 KPA)2 (Matched remote seals only with this range.) D 10/450 "H 2O (2.5/112.5 KPA)2 F 12.6/450 psi (87/3100 KPA)2 Output B 4-20 mAdc with HART Protocol 1,2 C 4-20 mAdc with HART Protocol & Integral Transient Suppressor D Spare Capsule Process Diaphragm H Hastelloy C-2762,3,7,10 S 316L SS2,6 A Hastelloy C-276 with 2 Remote Seals9,11 B Hastelloy C-276 with 1 Remote Seal on high side9,12 C Hastelloy C-276 with 1 Remote Seal on low side9,12 Body Parts Wetted Vent/Drain Process Conn. AA 316SS End 1/2 NPT1,2 AB 316SS Side (top) 1/2 NPT AC 316SS Side (bottom) 1/2 NPT AD 316SS Side (dual) 1/2 NPT AE 316SS End 1/4 NPT AF 316SS Side (top) 1/4 NPT AG 316SS Side (bottom) 1/4 NPT AH 316SS Side (dual) 1/4 NPT BA Hastelloy C-276 End 1/2 NPT BB Hastelloy C-276 Side (top) 1/2 NPT BC Hastelloy C-276 Side (bottom) 1/2 NPT BD Hastelloy C-276 Side (dual) 1/2 NPT BE Hastelloy C-276 End 1/4 NPT BF Hastelloy C-276 Side (top) 1/4 NPT BG Hastelloy C-276 Side (bottom) 1/4 NPT BH Hastelloy C-276 Side (dual) 1/4 NPT RR Remote Seals Fill Fluid B Silicone DC2001,2 C Inert11 D Paratherm 11 Output Indicator 5 4-1/2 Digit Digital SmartDisplay2 N Not Required5 Standard Options D B7M Bolts3 E B8M Bolts16 X Oxygen Cleaned Y Special Features4 N Not Required2,5 Mounting Bracket 1 2" Pipe Mount Bracket with SS Hardware2 2 Universal Bracket 3 2" Pipe Mount 316SS Bracket N Not Required5 Housing 1 Aluminum 1/2" - 14 NPT1,2 2 Aluminum M20 x 1.5 3 316 SS 1/2" - 14 NPT 4 316 SS M20 x 1.5 N Not Required 5 Hazardous Area Classification (TÜV Approval Standard) 2 CSA/CRN 3 FM/CSA All1,2 M CENELEC EEx d [ia] ia13 R SAA All & ABS Type Approved L CENELEC EExia & BASEEFA N Non-Approved W FM/CSA All & ABS Type Approved 345D D B H AA B 5 N 1 1 3 Sample Model Number See notes on page 105. 102 Moore Process Automation Solutions www.moore-solutions.com Critical Flanged Level Pressure Mounting Flange Size Rating Material Size Rating Material Size A 2" 150# CS J 3" 150# SS1 S 100mm B 2" 300# CS K 3" 300# SS T 100mm C 3" 150# CS 2 L 4" 150# SS U17 50mm D 3" 300# CS M 4" 300# SS V17 50mm E 4" 150# CS N17 50mm 10/16 Bar CS W 80mm F 4" 300# CS P 17 50mm 25/40 Bar CS X 80mm G* 2" 150# SS Q 80mm 10/16 Bar CS Y 100mm H* 2" 300# SS R 80mm 25/40 Bar CS Z 100mm Fill Fluid High Side Low Side B Silicone DC200 Silicone DC2001,2 C Fluorolube Inert D NEOBEE Paratherm E Silicone DC550 Silicone DC200 F Silicone DC704 Silicone DC200 G Syltherm 800 Silicone DC200 Output Indicator 5 4-1/2 Digit Digital SmartDisplay2 N Not Required Standard Options D B7M Bolts3 E B8M Bolts17 X Oxygen Cleaned Y Special Features4 N Not Required2 Mounting Bracket N Not Required Housing 1 Aluminum 1/2" - 14 NPT1,2 2 Aluminum M20 x 1.5 3 316 SS 1/2" - 14 NPT 4 316 SS M20 x 1.5 Hazardous Area Classification (TÜV Approval Standard) 2 CSA/CRN 3 FM/CSA All1,2 M CENELEC EEx d [ia] ia13 R SAA All & ABS Type Approved L CENELEC EExia & BASEEFA Type N N Non-Approved W FM/CSA All & ABS Type Approved 345F D B A0 C B 5 N N 1 Rating 10/16 Bar 25/40 Bar 10/16 Bar 25/40 Bar 10/16 Bar 25/40 Bar 10/16 Bar 25/40 Bar Material CS CS SS SS SS SS SS SS XTC Transmitters - Critical Pressure 345F Critical Flanged Level Pressure Transmitter Input Range: Span Limits, Min./Max. D 10/450 "H 2O (2.5/112.5 KPA)2 F 12.6/450 psi (87/3100 KPA)2 Output B 4-20 mAdc with HART Protocol 1,2 C 4-20 mAdc with HART Protocol & Integral Transient Suppressor Body Parts High Side Dia/Wetted Low Side Dia/Wetted Extension Length A0 316SS Hastelloy C-276/316SS Flush Mount 1,2 A2 316SS Hastelloy C-276/316SS 2"15 A4 316SS Hastelloy C-276/316SS 4"15 A6 316SS Hastelloy C-276/316SS 6"15 B0 Hastelloy C-276 Hastelloy C-276/316SS Flush Mount B2 Hastelloy C-276 Hastelloy C-276/316SS 2"15 B4 Hastelloy C-276 Hastelloy C-276/316SS 4"15 B6 Hastelloy C-276 Hastelloy C-276/316SS 6"15 C0 Monel Hastelloy C-276/316SS Flush Mount C2 Monel Hastelloy C-276/316SS 2"15 C4 Monel Hastelloy C-276/316SS 4"15 C6 Monel Hastelloy C-276/316SS 6"15 D0 Tantalum Hastelloy C-276/316SS Flush Mount G0 316SS Remote Seal Flush Mount G2 316SS Remote Seal 2"15 G4 316SS Remote Seal 4"15 G6 316SS Remote Seal 6"15 3 Sample Model Number See notes on page 105. Americas +1 215 646 7400 ext. 6613 Asia Pacific +65 299 6051 Europe +44 1935 706262 103 XTC Transmitters - Critical Pressure Critical Gauge Pressure 345G Critical Gauge Pressure Transmitter Input Range: Span Limits, Min/Max D 10/450" H 2O (2.5/112.5 KPA)2 F 12.6/450 psig (87/3100 KPA)2 G 300/5500 psig 2008/37920 KPA) 2 Output B 4-20 mAdc with HART Protocol 1,2 C 4-20 mAdc with HART Protocol & Integral Transient Suppressor D Spare Capsule Process Diaphragm H Hastelloy C-276 1,2,3 S 316L SS B Hastelloy C-276 with 1 Remote Seal (Specify AA for Body Parts) Body Parts Wetted Process Connection AA 316SS 1/2" NPT1,2 BA Hastelloy C-276 1/2" NPT Fill Fluid B Silicone DC2001,2 C Inert D Paratherm Output Indicator 5 4-1/2 Digit Digital SmartDisplay2 N Not Required 5 Standard Options X Oxygen Cleaned Y Special Features4 N Not Required 5 Mounting Bracket 1 2" Pipe Mount Bracket with SS Hardware2 2 Universal Bracket 3 2" Pipe Mount 316SS Bracket N Not Required 5 Housing 1 Aluminum 1/2" - 14 NPT1,2 2 Aluminum M20 x 1.5 3 316 SS 1/2" - 14 NPT 4 316 SS M20 x 1.5 N Not Required 5 Hazardous Area Classification (TÜV Approval Standard) 2 CSA/CRN 3 FM/CSA All1,2 M CENELEC EEx d [ia] ia13 R SAA All & ABS Type Approved L CENELEC EExia & BASEEFA N Non-Approved 5 W FM/CSA All & ABS Type Approved 345G F B H AA B 5 N 1 1 3 Sample Model Number See notes on page 105. 104 Moore Process Automation Solutions www.moore-solutions.com Tantalum Diaphragms 345DD B T TE B N N N 1 3 Sample Model Number NOTES: (1) (2) (3) (4) (5) (6) (7) (8) (9) XTC Transmitters - Critical Pressure 345 Absolute, Gauge, & Differential Critical Pressure Transmitter with Tantalum Diaphragms Type and Input Range: Span Limits, Min/Max Type Span Limits, Min/Max. Differential 10/450 "H2O (2.5/112.5 KPA) DD Gauge 10/450 "H2O (2.5/112.5 KPA) GD Gauge 12.6/450 psi (87/3100 KPA) GF 10/450 "H2O Abs (2.5/112.5 KPA) AD Absolute Absolute 12.6/450 psia (87/3100 KPA) AF Output B 4-20 mAdc with HART Protocol 1 C 4-20 mAdc with HART Protocol & Integral Transient Suppressor D Direct Connection to Model 348 Field Mounted Controller or Spare Capsule Diaphragm T Tantalum Body Parts Hi Side Lo Side Use with TB Hastelloy-C 316SS A, G TC Hastelloy-C Hastelloy-C D TD Monel 316SS A, G1 TE Monel Monel D1 Fill Fluid B Silicone DC200 C Inert13 Output Indicator 5 4-1/2 Digit Digital SmartDisplay N Not Required Standard Options D B7M Bolts3 E B8M Bolts16 X Oxygen Cleaned Y Special Features4 N Not Required 5 Mounting Bracket 1 2" Pipe Mount Bracket with SS Hardware 2 Universal Bracket 3 2" Pipe Mount 316SS Bracket N Not Required 5 Housing 1 Aluminum 1/2 - 14 NPT1 2 Aluminum M20 x 1.5 3 316 SS 1/2" - 14 NPT 4 316 SS M20 x 1.5 N Not Required 5 Hazardous Area Classification (TÜV Approval Standard) 2 CSA/CRN 3 FM/CSA All1 M CENELEC EEx d [ia] ia13 R SAA All & ABS Type Approved L CENELEC EExia & BASEEFA N Non-Approved W FM/CSA All & ABS Type Approved Standard for all ranges. Stock model selection. NACE MR0175 compliance requires this option. Please describe the modification or provide a quotation reference number. Required selection for OUTPUT option “D”, direct connection to the Moore 348. Standard on Input Ranges A & B. Standard on Input Ranges D & F. Must specify Body Parts code “RR”. Must select Body Parts “AA”. Americas +1 215 646 7400 ext. 6613 (10) (11) (12) (13) (14) (15) (16) (17) Not available with Input Range “A”. Not available with Input Range “A” or “B”. Available with Body Parts “TD” or “TE” only. CENELEC EExd & SAA units are only available with OUTPUT code “B”. 2" flanges with an extension or not available. 3" and 4" flanges with an extension will fit into Schedule 80 and larger i.d. pipes. B8M (316SS) bolting may have a reduced pressure rating. Consult Moore for more information. Extended diaphragm not available with these sizes. Asia Pacific +65 299 6051 Europe +44 1935 706262 105 MODEL DIFFERENCES & MODIFICATIONS If no range is selected, the instrument will be calibrated as follows: Range Code XTC Transmitters - Critical Pressure A B D F G 106 Default Calibration Common modifications can be specified by selecting a Y in the Special Features category and describing the modification. Always consult your salesperson before ordering a modification. -0.5 to 0.5 "H2O 0 to 10 "H2O 0 to 100 "H2O (or "H2O abs) 0 to 100 PSI (or PSIA) 0 to 1000 PSIG TRANSMITTER COMPONENTS Moore Process Automation Solutions www.moore-solutions.com INSTALLATION DRAWINGS XTC Transmitters - Critical Pressure Models 345A and 345G Americas +1 215 646 7400 ext. 6613 Asia Pacific +65 299 6051 Europe +44 1935 706262 107 XTC Transmitters - Critical Pressure Model 345D and Models 345A and 345G with Tantalum Diaphragms 108 Moore Process Automation Solutions www.moore-solutions.com Model 345F Flange Mounted Transmitter Flange Dimensions SIZE DIM “D” 2"-150# 2"-300# 3"-150# 3"-300# 4"-150# 4"-300# DIM “BC” DIM “T” DIM “RF” BOLT BOLT DIA. NO. 6.00 6.50 7.50 8.25 9.00 10.00 (152.40) (165.10) (190.50) (209.55) (228.60) (254.00) 4.75 (120.65) 5.00 (127.00) 6.00 (152.40) 6.625 (168.28) 7.50 (190.50) 7.875 (200.03) 0.75 0.88 0.94 1.13 0.94 1.25 (19.05) (22.23) (23.81) (28.58) (23.81) (31.75) 5/8 5/8 0.06 (1.58) 5/8 3/4 5/8 3/4 4 8 4 8 8 8 6.50 6.50 7.87 7.87 8.66 9.25 (165.00) (165.00) (200.00) (200.00) (220.00) (235.00) 4.92 4.92 6.30 6.30 7.09 7.48 0.71 0.79 0.79 0.94 0.79 0.94 (18.00) (20.00) (20.00) (24.00) (20.00) (24.00) M16 M16 0.12 (3.00) M16 M16 M16 M20 4 4 8 8 8 8 50MM-10/16 BAR 50MM-25/40 BAR 80MM-10/16 BAR 80MM-25/40 BAR 100MM-10/16 BAR 100MM-25/40 BAR (125.00) (125.00) (160.00) (160.00) (180.00) (190.00) FLANGE PER ANSI B16.5 DIN 2526 TYPE C DIM “ED” 1.95 1.95 2.81 2.81 3.70 3.70 (49.53) (49.53) (71.37) (71.37) (93.98) (93.98) XTC Transmitters - Critical Pressure Flange and Extension Dimensions Consult Moore Extension Length (Not available on 2" or 50mm flanges.) DIM “L” 0 (0.00) 2.00 (50.80) 4.00 (101.60) 6.00 (152.40) Americas +1 215 646 7400 ext. 6613 Asia Pacific +65 299 6051 Europe +44 1935 706262 109 XTC Transmitters - Critical Pressure Notes 110 Moore Process Automation Solutions www.moore-solutions.com