UM341-2 MODEL DESIGNATIONS AND SPECIFICATIONS 9.0 MODEL DESIGNATIONS AND SPECIFICATIONS This section contains the model designation tables, a comprehensive accessory list, and functional and performance specifications, and hazardous area classifications for all XTC Model 341 Pressure Transmitters. IMPORTANT Before installing, calibrating, troubleshooting or servicing a transmitter review this section carefully for applicable specifications and hazardous area classifications. 9.1 MODEL DESIGNATIONS Tables 9.1, 9.2, 9.3, and 9.4 on the following pages identify each model designation entry on a transmitter's nameplate. The nameplate also carries other important transmitter information in addition to the model designation: • Bill of material number (B/M) • Serial number • Span limits • Maximum working pressure (MAX. WPR) • Factory calibration (FCTY CAL) • Certifications. IMPORTANT Confirm transmitter model by referring to the transmitter's model designation on its nameplate and the above Tables before installing, applying or removing power, configuring or servicing. 9.2 ACCESSORIES Table 9.5 lists the accessories available for all Model 341s. Additional information about many transmitter accessories can be found in PI34-3, XTC Transmitter Accessory Guide. Notes for Model Designation Tables 9.1 through 9.4 1. 2. 3. 4. 5. 6. 7. 8. 9. Standard for all ranges. Stock model selection. Must specify Body Parts code “AE.” Please describe the modification or provide a quotation reference number. Not available with FM/CSA approvals. Must specify Body Parts code “RR.” Not available with Input Range “B.” Mounting hardware purchased separately. Must select housing “2” or “4.” August 1997 9-1 MODEL DESIGNATIONS AND SPECIFICATIONS UM341-2 TABLE 9.1 Model 341D, Model Designation Basic Model Number 341D Differential Pressure Transmitter Input Span Limits, Min./Max. B 0.75 inH2O / 15 inH2 O (0.186 kPa / 3.73 kPa) Notes indicated by (#). D 10 inH2O / 450 inH2 O (2.49 kPa / 112 kPa) See page 9-1 for Notes. Output (1)(2) A Standard, 4-20 mAdc with HART Protocol E Enhanced, 4-20 mAdc with HART Protocol Process Diaphragm S 316L Stainless Steel A 316L SS with 2 Remote Seals (specify RR for body parts) (6) B 316L SS with 1 Remote Seal on high side (specify RR for body parts) (6)(7) C 316L SS with 1 Remote Seal on low side (specify RR for body parts) (6)(7) Body Parts Wetted Vent/Drain Process Connection AA 316 SS Dual ½ NPT (1)(2) AE 316 SS Dual ¼ NPT RR Remote Seal(s) None ¼ NPT Fill Fluid B Silicon DC200 Output Indicator 1 Analog LCD Meter 0-100% Scale (2) N Not Required Standard Options X Oxygen Cleaned Y Special Feature (4) N Not Required (2) Mounting Bracket 1 2" Pipe Mount Bracket with SS Hardware (2) 2 Universal Mounting Bracket - 2" Pipe or Flat Surface 3 Stainless Steel "L" Mounting Bracket - 2" Pipe Mount N Not Required Housing 1 Aluminum ½-14 NPT (2) 2 Aluminum M20 x 1.5 (5) 3 316 SS ½-14 NPT 4 316 SS M20 x 1.5 (5) Hazardous Area Classification 3 FM/CSA All (1)(2) L CENELEC EExia & BASEEFA Ex N M CENELEC EExd R SAA All & ABS Type Approved (9) W FM/CSA All & ABS Type Approved N Not Required 341D 9-2 D A S AA N N N N 1 3 Sample Model Number August 1997 UM341-2 MODEL DESIGNATIONS AND SPECIFICATIONS TABLE 9.2 Model 341A, Model Designation Basic Model Number 341A Absolute Pressure Transmitter Input Span Limits, Min./Max. D 10 inH2O abs / 450 inH2 O abs (2.49 kPa abs / 112 kPa abs) Notes indicated by (#). E 9 psia / 100 psia (62.0 kPa abs / 689 kPa abs) See page 9-1 for Notes. Output (1) A Standard, 4-20 mAdc with HART Protocol E Enhanced, 4-20 mAdc with HART Protocol Process Diaphragm S 316L Stainless Steel B 316L SS with 1 Remote Seal (3) Body Parts Wetted Vent/Drain Process Connection AA 316 SS None ½ NPT (1) AD 316 SS Dual ½ NPT AE 316 SS None ¼ NPT AH 316 SS Dual ¼ NPT Fill Fluid B Silicon DC200 Output Indicator 1 Analog LCD Meter 0-100% Scale N Not Required Standard Options X Oxygen Cleaned Y Special Feature (4) N Not Required Mounting Bracket 1 Standard Mounting Bracket - 2" Pipe Mount 2 Universal Mounting Bracket - 2" Pipe or Flat Surface 3 Stainless Steel "L" Mounting Bracket - 2" Pipe Mount N Not Required Housing 1 Aluminum ½-14 NPT 2 Aluminum M20 x 1.5 (5) 3 316 SS ½-14 NPT 4 316 SS M20 x 11.5 (5) Hazardous Area Classification 3 FM/CSA All (1) L CENELEC EExia & BASEEFA Ex N M CENELEC (EExd) R SAA All & ABS Type Approved (9) W FM/CSA All & ABS Type Approved N Not Required 341A D August 1997 A S AA B 1 N N 1 3 Sample Model Number 9-3 MODEL DESIGNATIONS AND SPECIFICATIONS UM341-2 TABLE 9.3 Model 341G, Model Designation Basic Model Number 341G Gage Pressure Transmitter Input Span Limits, Min./Max. D 10 inH2O / 450 inH2 O (2.49 kPa / 112 kPa) (2) Notes indicated by (#). E 9 psig / 100 psig (62.0 kPa / 689 kPa) (2) See page 9-1 for Notes. F 60 psig / 600 psig (414 kPa / 4.14 MPa) (2) Output A Standard, 4-20 mAdc with HART protocol (1)(2) E Enhanced, 4-20 mAdc with HART protocol. Process Diaphragm S 316L Stainless Steel (1)(2) B 316L SS with 1 Remote Seal (3) Body Parts Wetted Vent/Drain Process Connection AA 316 SS None ½ NPT (1)(2) AD 316 SS Dual ½ NPT AE 316 SS None ¼ NPT AH 316 SS Dual ¼ NPT Fill Fluid B Silicon DC200 Output Indicator 1 Analog LCD Meter 0-100% Scale (2) N Not Required Standard Options X Oxygen Cleaned Y Special Features (4) N Not Required (2) Mounting Bracket 1 Standard Mounting Bracket - 2" Pipe (2) 2 Universal Mounting Bracket - 2" Pipe or Flat Surface 3 Stainless Steel "L" Mounting Bracket - 2" Pipe N Not Required Housing 1 Aluminum ½-14 NPT (2) 2 Aluminum M20 x 1.5 (5) 3 316 SS ½-14 NPT 4 316 SS M20 x 1.5 (5) Electrical Connection 1 2-14 NPT 2 M20 x 1.5 Hazardous Area Classification 3 FM/CSA All (1)(2) L CENELEC EExia & BASEEFA Ex n M CENELEC (EEx d) R SAA All & ABS Type Approved (9) N Not Required W FM/CSA & ABS Type Approved 341G 9-4 D 1 S 2 B N N N N 1 3 Sample Model Number August 1997 UM341-2 MODEL DESIGNATIONS AND SPECIFICATIONS TABLE 9.4 Model 341P, Model Designation Basic Model Number 341P Gage Pressure Transmitter with Flush Diaphragm Process Connections Input Span Limits, Min./Max. D 1 psig / 30 psig (6.895 kPa / 206.84 kPa) (2) F 10 psig / 150 psig (68.95 kPa / 1.034 MPa) (2) Output A Standard, 4-20 mAdc with HART protocol (1)(2) E Enhanced, 4-20 mAdc with HART protocol Process Diaphragm H Hastelloy C-276 Body Parts Wetted Process Connection AB 316 SS Miniature Bolt-In-Place, 1.049" Diameter (2)(8) AS 316 SS Standard Thread-Mount, 1.59" Diameter Fill Fluid B Silicon DC200 Output Indicator 1 Analog LCD Meter 0-100% Scale N Not Required (2) Standard Options Y Special Features (4) N Not Required (2) Mounting Bracket N Not Required Housing 1 Aluminum 2-14 NPT (2) 2 Aluminum M20 x 1.5 (2) Hazardous Area Classification 6 CSA IS N Not Required (2) 341P F August 1997 A H AB B N N N 1 N Notes indicated by (#). See page 9-1 for Notes. Sample Model Number 9-5 MODEL DESIGNATIONS AND SPECIFICATIONS UM341-2 TABLE 9.5 Model 341 Accessories DESCRIPTION MODEL 341 PART NUMBER A D G P Three-Valve Manifold, Steel* M M M F 16275-252 Three-Valve Manifold, 316 SS* M M M F 16275-251 Transient Protector* M M M M 14999-287 General Purpose Power Supply, 24 Vdc, 2A* M M M M 15124-1 Field Mounted Power Supply, 28 Vdc, 125 mA* M M M M 16055-299 Cap Wrench for 341P and CENELEC Explosion Proof models M M M M 20027-83 Mounting Bracket Kits: ! Standard Bracket, Pipe Mount ! Universal Bracket, Pipe and Flat Surface Mount ! L-Shaped Bracket, Stainless Steel, Pipe Mount M M M F Analog LCD Meter Kit, 0-100% Linear (includes meter and enclosure cap)* M M M M 20027-241 Analog LCD Meter Kit, 0-100% Linear, Stainless Steel Enclosure Cap* M M M M 20027-485 Gasket ! Standard TFE/PTFE ! Miniature Buna-N O-Ring (bolt-in-place mounting) F F F M Plug ! Standard Threaded ! Miniature Bolt-In-Place F Spud Kit (includes spud, O-ring or gasket, and plug) ! Standard Threaded ! Miniature Bolt-In-Place F Miniature Bolt-In-Place SS Set Screw and Lockwasher F F F M Aluminum Test Spud ! Standard Threaded ! Miniature Bolt-In-Place F F F M Spud ! Standard Threaded ! Miniature Bolt-In-Place F Universal HART Communicator M 16275-121 20027-166 20027-167 20027-331 2938-50 F F M 20027-311 20027-313 F F M 20027-314 20027-316 20027-317 20027-318 20027-320 F F M 20027-332 20027-336 M M M 20027-275 * Refer to PI34-3, XTC Transmitter Accessory Guide for additional details. M = For use with transmitter model in table column head; F = Not for use 9-6 August 1997