SITRANS TF Catalog Specification Sheet

© Siemens AG 2016
Temperature Measurement
Transmitters for field mounting
SITRANS TF280 WirelessHART
■ Overview
■ Application
The SITRANS TF280 is a WirelessHART field device for temperature measurement with a Pt100 sensor.
This sensor can be installed directly on the field device, or connected at an offset with a cable connection. On the wireless
communication side, the transmitter supports the WirelessHART
standard. A HART modem can be connected to the transmitter
particularly for initial parameterization. Alternatively the device
can be commissioned comfortably by means of the local pushbuttons w/o any additional handset devices.
2
It can be used in all industries and applications in non-explosive
areas.
■ Design
The SITRANS TF280 has a robust aluminum enclosure and is
suitable for outside use. It conforms with the IP65 safety class.
SITRANS TF280 for flexible and cost-effective temperature measurements
• Supports the WirelessHART standard (HART V 7.1)
• Very high security level for wireless data transmission
• Built-in local user interface (LUI) with 3-button operation
• Optimum representation and readability using graphical display (104 x 80 pixels) with integrated backlight
• Stand-by (deep sleep phase) mode can be turned on and off
with push of a button
• Battery power supply
• Battery life time up to 5 years
• Extend battery life time with HART modem interface which can
be switch off
• Optimized power consumption through new design, and increase in battery life time
• Simple configuration thanks to SIMATIC PDM
• Housing meets IP65 degree of protection
• Supports all Pt100 sensors as per IEC 751/DIN EN 60751
■ Benefits
The SITRANS TF280 is a temperature transmitter that features
WirelessHART as the standard communication interface.
Also available is a wired interface to connect a HART modem:
• Flexible temperature measurement
• Save costs on wiring at difficult installation conditions. Wireless technology offers cost advantages in cases where extensive wiring costs would normally apply.
• It enables additional hitherto unfeasible measuring points,
particularly for monitoring purposes
• Easy installation also on moveable equipment parts
• Enables cost-effective temporary measurements, for example
for process optimizations.
• Optimum solution in addition to wired communication and for
system solutions in process automation
The operation temperature range is -40 to +80 °C
(-40 to +176 °F). Power supply is provided through an integrated
battery, which is available as an accessory. The device is only
approved for operation with this battery.
The antenna features a rotatable joint which can be used for
directional alignment. Wireless signals can thus be optimally
received and transmitted.
A special highlight is the possibility to operate directly on the
device with 3 push buttons. It perfectly matches the strategy of
all new Siemens field devices.
Using the device’s push buttons, it is easy to turn the HART
modem interface of the device on and off. The device can be put
to passive status and reactivated at any time. This helps to
extend the life time of the battery.
The SITRANS TF280 transmitter features a cable gland or a
Pt100 sensor including protective piping.
■ Function
The SITRANS TF280 can join to a WirelessHART network. It can
be parameterized and operated through this network. Measured
process values are transmitted via the network to the
SIEMENS IE/WSN-PA LINK.
Field device data received by the IE/WSN-PA LINK is transmitted
to the connected systems, for example the process control system SIMATIC PCS 7. For an introduction of WirelessHART,
please see the FI 01 catalogue Sec. 8 or
www.siemens.com/wirelesshart.
Detailed information on IE/WSN-PA LINK can be found in the
FI 01 catalogue Sec. 7 or www.siemens.com/wirelesshart.
■ Integration
Connecting to SIMATIC PCS 7
The integration of field devices in SIMATIC PCS 7 and other process control systems can be now done seamlessly and cost-effectively with wireless technology, especially in situations where
high wiring costs may be expected. Of particular interest are
measuring points which are to be added and for which no wiring
is available.
Where larger distances between the IE/WSN-PA LINK and control systems need to be overcome, this connection can also be
implemented on a wireless and cost-effective basis using the
SCALANCE W series of products. Siemens WirelessHART devices operate with optimum coexistence to SCALANCE W family
products.
2/166
Siemens FI 01 · 2016
© Siemens AG 2016
Temperature Measurement
Transmitters for field mounting
SITRANS TF280 WirelessHART
■ Technical specifications
ES
OS
MS
Industrial Ethernet
SITRANS
AW210
SIMATIC
system
SITRANS
AW200
The SITRANS TF280 can be mechanically installed in two ways:
• Direct at the measuring point with a M20x1.5 thread.
A connection to other threads can be done via the adapter.
• Remotely from the Pt100 sensor, which is connected to the
transmitter via a cable.
The data in the following table refer to the transmitter only excluding a connected sensor, except as noted otherwise.
Input
Sensor
SIMATIC ET 200
with HART support
Wireless
HART
IE/WSNPA LINK
• Sensor type
Pt100 as per
IEC 751/DIN EN 607511)
• Connection
Two, three or four-wire system
• Measuring range
-200 ... +850 °C (-328 ... 1560 °F)
Cable length SITRANS TF280 and
Pt100 sensor element
3m
Measuring accuracy2)
SITRANS SITRANS
P280
TF280
PROFIBUS
SITRANS
AW210
DP/PA
LINK
Accuracy
< 0.04 % of the measuring range
Long-term drift
< 0.035 % of the measuring range
in first year
Ambient temperature effect
max. 0.1 °C/10 K
Rated conditions
PROFIBUS PA
Integration of a meshed network into SIMATIC PCS 7
Ambient temperature
-40 ... +80 °C (-40 ... +176 °F)
Storage temperature
-40 ... +85 ° C (-40 ... +185 °F)
Relative humidity
< 95%
Climatic class
4K4H in accordance with
EN 60721-3-4
(stationary use at locations not protected against weather)
Degree of protection
IP65/NEMA 4
Max. permissible temperature at
transmitter for directly mounted
Pt100
80 °C (176 °F)
■ Configuration
Configuration of the SITRANS TF280 transmitter may be carried
out as follows:
• Initial commissioning for the SITRANS TF280 with SIMATIC
PDM is generally carried out via a HART modem or the integrated local user interface, since the network ID and join Key
must be set up on the device before it can be accepted and
integrated into the WirelessHART network.
• Once it is integrated into the network, the device can be conveniently operated with the WirelessHART network or onsite
with a HART modem or via the local user interface.
Design
Enclosure
Die-cast aluminum
Shock resistance
in accordance with
DIN EN 60068-2-29 / 03.95
Resistance to vibration
DIN EN 60068-2-6/12.07
Weight
• without battery
1.5 kg (3.3 lb)
• with battery
1.6 kg (3.5 lb)
Dimensions (W x H x D)
See "Dimensional drawing"
Thread for cable gland/
sensor connection
M20x1.5
other threads via adapter
Material of protective tubes and
process connection (only for premounted sensor pipe)
Stainless steel 1.4404 (AISI 316L,
UNS S 31603, X2CrNiMo17-12-2)
Cable between transmitter and
sensor element
 3 m für two-, three- or four-wire
connections
Cable resistance < 1  (setting
range in m 0...9999)
Sensor break
Recognized
Siemens FI 01 · 2016
2/167
2
© Siemens AG 2016
Temperature Measurement
Transmitters for field mounting
SITRANS TF280 WirelessHART
2
Displays and controls
Selection and Ordering data
Article No.
Display (with illumination)
SITRANS TF280 WirelessHART Temperature
transmitter
(Required battery not included with delivery, see
accessories)
7 MP 1 1 1 0 -
• Size of display
104 x 80 pixels
• Number of digits
Adjustable
• Number of spaces after comma
Adjustable
Setting options
• on site with 3 push buttons
• with SIMATIC PDM or HART Communicator
Auxiliary power
Battery
3.6 V DC
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Connections/cable entry
Cable gland M20x1.51)
Sensor pipe with Pt100, G½" male thread, premounted and connected
}
}
C
D
Display
Communication
Wireless standard
WirelessHART V7.1 conforming
Transmission frequency band
2.4 GHz (ISM-Band)
Range under reference conditions
Up to 250 m (line of sight) in outside areas
Up to 50 m (greatly dependent on
obstacles) in Inside areas
Communication interfaces
0 A777 - 0 77 0
• HART communication with HART
modem
• WirelessHART
Certificates and approvals
Wireless communication approvals R&TTE, FCC
General Product Safety
CSAUS/C, CE, UL
Pressure equipment directive
This device is not included in the
pressure device guideline; classification according to pressure
device guideline
(PED 2014/68/EU), Directive 1/40;
article 1, paragraph 2.1.4
1)
Pre-mounted Pt100: Class A (maximum MES: 0.15 + 0.002*|t| °C)
2)
Calculation for errors:
Probable total error = (MES2 + AET2 + LTD2 + ATE2)
Max. error = MES + AET + LTD + ATE
|t|: Absolut value of measured temperature
MES: Measurement error of sensor
AET: Accuracy error transmitter
LTD: Long term drift
ATE: Ambient temperature drift
Digital display, visible
}
1
Enclosure
Die-cast aluminum
}
1
Explosion protection
Not included
A
}
Antenna
Variable, attached to device
}
A
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s) and plain text.
Measuring point number (TAG Nr.)
max. 16 digits entered in plain text
Y15: ....................
Y15
Measuring point message
max. 27 characters entered in plain text:
Y16: ....................
Y16
Article No.
Accessories
Lithium battery for SITRANS TF280/P280
}
Mounting bracket, steel
7MP1990-0AA00
7MF4997-1AC
Mounting bracket, stainless steel
}
7MF4997-1AJ
Cover, die-cast aluminum, without window
}
7MF4997-1BB
Cover, die-cast aluminum, with window
7MF4997-1BE
Thread adapter M20x1.5 (male thread) on
½-14 NPT (female thread)
}
7MP1990-0BA00
Thread adapter M20x1.5 (male thread) on
G½ (female thread)
}
7MP1990-0BB00
IE/WSN-PA Link
HART modem with USB interface
SIMATIC PDM
see Sec. 7
}
7MF4997-1DB
see Sec. 8
} Available ex stock.
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
1)
2/168
Siemens FI 01 · 2016
Please order sensor separately.
© Siemens AG 2016
Temperature Measurement
Transmitters for field mounting
SITRANS TF280 WirelessHART
■ Dimensional drawings
2
Antenna
112 (4.4)
130 (5.12)
Ø 80 (3.15)
242 (9.5)
90
°
SW27
Pt100
154 (6.06)
Ø 80 (3.15)
Ø 8 (0.32)
G½B
52 (2.05)
101 (3.98)
14 (0.55)
352 (13.9)
SITRANS TF280 WirelessHART temperature transmitter with Pt100, dimensions in mm (inch).
Please see the dimensional drawing of the mounting bracket on page 1/192.
Siemens FI 01 · 2016
2/169
© Siemens AG 2016
Temperature Measurement
Transmitters for field mounting
SITRANS TF280 WirelessHART
2
112 (4.4)
130 (5.12)
Ø 80 (3.15)
242 (9.5)
90
°
Antenna
154 (6.06)
52 (2.05)
Ø 80 (3.15)
Cable gland
for cable 6 ... 12 mm
(0.24 ... 0.47 inch)
264 (10.4)
SITRANS TF280 WirelessHART temperature transmitter, dimensions in mm (inch)
Please see the dimensional drawing of the mounting bracket on page 1/192.
2/170