FPN Data sheet Sensing element/Gauge ■Features Dual-in-line package (DIP) ■Ordering Information FPN-07P G R Terminal leadsdirection Model Rated Pressure (PSI) Pressure type G:Gauge Pressure No Mark: R : Weight (grams) RoHS compliance 1.1 Measurable pressure range(kPa) -13.79 to 13.79 FPN-02PG FPN-02PGR -34.47 to 34.47 FPN-05PG FPN-05PGR -48.26 to 48.26 FPN-07PG FPN-07PGR Part number ■Specifications Model 02PG 05PG 07PG Recommended operating conditions Pressure type Gauge pressure Rated pressure 13.79 34.47 48.26 Measurable pressure range -13.79 to 13.79 -34.47 to 34.47 -48.26 to 48.26 Temperature range 0 to 50 Pressure media Non-corrosive gases only (No liquid) Excitation current (Constant) 1.5 Absolute maximum rating Maximum load pressure Twice of rated pressure Maximum excitation current 3.0 Operating temperature 0 to 80 Storage temperature -20 to 100 Operating humidity 30 to 80 (Non dew condition) Electric characteristics (Drive Current 1.5mA constant ,ambient temperature Ta=25deg.C) Output span voltage 40 to 130 (at 0kPa to rated pressure) Offset voltage +/-25 (at 0kPa) Bridge resistance 4000 to 6000 Response time 2 (for the reference) Accuracy TSO* +/-10 +/-8 TCS* 5.0 2.5 Linearity +/-0.6 +/-0.3 Pressure hysteresis +/-1.0 +/-0.7 *TSO : Temperature sensitivity of offset voltage(Temperature range from 0-50 deg.C) *TCS : Temperature coefficient of output span voltage(Temperature range from 0-50 deg.C) 1 Unit kPa kPa deg.C mADC mADC deg.C deg.C %RH mV mV Ω msec. %FS/0-50deg.C %FS/0-50deg.C %FS %FS FPN Data sheet Sensing element/Gauge P1= 0 kPa P2= 1/2 x P3 (kPa) P3= reted pressure (kPa) T1= 0 deg.C T2= 25 deg.C T3= 50 deg.C Offset voltage (mV) Voff = V(P1,T) Voff(0) = V(P1,T1) Voff(25) = V(P1,T2) Voff(50) = V(P1,T3) Output voltage at full scale (mV) Vfs = V(P3,T) Vfs(0) = V(P3,T1) Vfs(25) = V(P3,T2) Vfs(50) = V(P3,T3) Output span voltage (mV) SV = Vfs - Voff SV(0) = Vfs(0) - Voff(0) SV(25) = Vfs(25) - Voff(25) SV(50) = Vfs(50) - Voff(50) Temperature sensitivity of offset voltage (%FS) TSO = {LARGER ONE} / SV(25) x 100 LARGER ONE = larger absolute value which of {Voff(0)-Voff(25)} and {Voff(50)-Voff(25)} Temperature coefficient of output span voltage (%FS) TCS = {max[SV(0),SV(25),SV(50)] - min[SV(0),SV(25),SV(50)] } / SV(25) x 100 Linearity (%FS) NL = {V(P2,T2) - [Voff(25)+Vfs(25)]/2 } / SV(25) x 100 Pressure hysteresis (%FS) Phys = {Voff’(25) - Voff(25) } / SV(25) x 100 Voff’(25) : Output voltage against P1 after stressing by P3 pressure. 2 FPN Data sheet Sensing element/Gauge ■Outline dimensions■ 3 FPN Data sheet Sensing element/Gauge ■Connection diagram■ ■Output characteristics■ ↑Output voltage(mV) Output span voltage Offset voltage -Rated pressure 0kPa Atomospheric pressure Note ; Rated pressure →Pressure(kPa) Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. Please keep the sensors sealed using static shielding bags on storage.The pins of the sensor are plated by Ag. If the sensors expose to an atmosphere, the pins will be black by sulfuration. Please set Zero-calibration function up your products. The offset voltage may be shifted some mechanical stress such as mounting, installation and etc. over longtime using. If you have any questions regarding technical issues or specifications, please contact us. Fujikura Ltd. Sensor Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected] 4