FUJIKURA FPN-07PG

FPN,FGN-6 Data sheet
Sensing element/Gauge
Features
Applications
. Dual-In-line-Package (DIP)or SMD, Easy to mount on PCB
. Vacuum pressure measurable
. Home use Non-Invasive Blood Pressure(NIBP)monitors
. Vacuum cleaner
. Washing machine
Part number for ordering
FGN - 6 07P G S R
Rated pressure
(PSI)
Length of the pressure port
(FGN only)
Pressure type
6 : 6mm
G : Gauge
Model
FPN
FGN
Pressure type
Terminal leads direction(See Outline Diagram)
No mark :
R :
Terminal leads configuration
No mark : DIP(FPN)
S : Surface mount package(FGN)
Gauge pressure
FPN
FGN-6
Dual-In-line-Package(DIP)
Surface mount package, 6mm pressure port
Model
Package configuration
Measurable pressure range(kPa)
13.79 13.79
34.47 34.47
48.26 48.26
98.07 103.4
Part number for ordering
FPN-02PGR
FPN-05PGR
FPN-07PGR
FPN-15PGR
FPN-02PG
FPN-05PG
FPN-07PG
FPN-15PG
FGN-602PGSR
FGN-605PGSR
FGN-607PGSR
FGN-615PGSR
Specifications
Model/Rated pressure
02PG
Recommended operating conditions
Pressure type
Rated pressure
13.79
0.141
13.79 13.79
05PG
07PG
Gauge pressure
34.47
48.26
0.352
0.492
34.47 34.47
48.26 48.26
Non-corrosive gas
1.5
Accuracy
Measurable pressure range
Pressure media
Excitation current(Constant)
Absolute maximum rating
Maximum load pressure
Twice of rated pressure
Maximum excitation current
3.0
Operating temperature
0 80
Storage temperature
20 100
Operating humidity
30 80(No dew condensation)
Electric performances/characteristics(Excitation current I=1.5mA constant, Ambient temperature Ta=25 )
Full scale span voltage
40 130
Offset voltage
40
25
Bridge impedance
4000 6000
Mechanical response time
2(For the reference)
Temperature sensitivity of offset(TSO)
10.0
8.0
Temperature coefficient of sensitivity(TCS)
5.0
2.5
Linearity
0.6
0.3
Pressure hystersis
1.0
0.7
1
15PG
103.4
1.055
98.07 103.4
unit
kPa
kg/cm2
kPa
mADC
mADC
RH
mV
mV
msec
FS/0 50
FS/0 50
FS
FS
FPN,FGN-6 Data sheet
Sensing element/Gauge
Outline dimensions
unit(mm)
FPN
8
2.2
4
5
R1.5
1
Pressure port
0.8
4.5
5
6
3
2
1
C0.5
3
2
4
0.6
Vent hole
3
14
15.24(600mil)
6
max 15
5
0.2
4
12
Terminal leads
Labelled faceplate
6.8
2.8
Recommended footprint for PCB
6- 0.9(Diameter of through holes)
2.54 2.54
2.54 2.54
1.2
0.5
60
6- 1.8(Diameter of lands)
15.2
unit(mm)
unit(mm)
FPN-R
4
0.2
8
0.8
Pressure port
2.2
3
14
R1.5
4
5
6
3 2
4.5
1
15.24(600mil)
5
max 15
6
4
5
12
C0.5
1
2
0.6
Vent hole
3
Terminal leads
Recommended footprint for PCB
2.54 2.54
6- 0.9(Diameter of through holes)
6- 1.8(Diameter of lands)
2.54 2.54
60
1.2
0.5
Labelled faceplate
2.8
6.8
15.2
2
unit(mm)
FPN,FGN-6 Data sheet
Sensing element/Gauge
Outline dimensions
unit(mm)
FGN-6
2.54 2.54
0.8
Pressure port
2
6
5
3
7
1
4
3
7
Vent hole
Labelled faceplate
6
5
0.5
Recommended footprint for PCB
2-R0.5
4
1
Projections
2- 1(Holes for projections)
1.4
1.7
1
2
Land-pads
3
6.2
10.3
Projections
2.54 2.54
0.8
MA
0.25
X.
15
3.5
9.5
6
Index
6.2
9.4
unit(mm)
Connection diagram
unit(mm)
FPN, FGN-6
i
1.5mA
2
Output voltage
R2
Constant
current
source
R1
1
3
6
R3
R4
5
1
VR0
6
Zero balancing trimmer (VR0) is available.
VR0 :200
Note ; Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us.
Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538
3
E-mail : [email protected]