FPN,FGN-6 Data sheet Sensing element/Gauge Features Applications . Dual-In-line-Package (DIP)or SMD, Easy to mount on PCB . Vacuum pressure measurable . Home use Non-Invasive Blood Pressure(NIBP)monitors . Vacuum cleaner . Washing machine Part number for ordering FGN - 6 07P G S R Rated pressure (PSI) Length of the pressure port (FGN only) Pressure type 6 : 6mm G : Gauge Model FPN FGN Pressure type Terminal leads direction(See Outline Diagram) No mark : R : Terminal leads configuration No mark : DIP(FPN) S : Surface mount package(FGN) Gauge pressure FPN FGN-6 Dual-In-line-Package(DIP) Surface mount package, 6mm pressure port Model Package configuration Measurable pressure range(kPa) 13.79 13.79 34.47 34.47 48.26 48.26 98.07 103.4 Part number for ordering FPN-02PGR FPN-05PGR FPN-07PGR FPN-15PGR FPN-02PG FPN-05PG FPN-07PG FPN-15PG FGN-602PGSR FGN-605PGSR FGN-607PGSR FGN-615PGSR Specifications Model/Rated pressure 02PG Recommended operating conditions Pressure type Rated pressure 13.79 0.141 13.79 13.79 05PG 07PG Gauge pressure 34.47 48.26 0.352 0.492 34.47 34.47 48.26 48.26 Non-corrosive gas 1.5 Accuracy Measurable pressure range Pressure media Excitation current(Constant) Absolute maximum rating Maximum load pressure Twice of rated pressure Maximum excitation current 3.0 Operating temperature 0 80 Storage temperature 20 100 Operating humidity 30 80(No dew condensation) Electric performances/characteristics(Excitation current I=1.5mA constant, Ambient temperature Ta=25 ) Full scale span voltage 40 130 Offset voltage 40 25 Bridge impedance 4000 6000 Mechanical response time 2(For the reference) Temperature sensitivity of offset(TSO) 10.0 8.0 Temperature coefficient of sensitivity(TCS) 5.0 2.5 Linearity 0.6 0.3 Pressure hystersis 1.0 0.7 1 15PG 103.4 1.055 98.07 103.4 unit kPa kg/cm2 kPa mADC mADC RH mV mV msec FS/0 50 FS/0 50 FS FS FPN,FGN-6 Data sheet Sensing element/Gauge Outline dimensions unit(mm) FPN 8 2.2 4 5 R1.5 1 Pressure port 0.8 4.5 5 6 3 2 1 C0.5 3 2 4 0.6 Vent hole 3 14 15.24(600mil) 6 max 15 5 0.2 4 12 Terminal leads Labelled faceplate 6.8 2.8 Recommended footprint for PCB 6- 0.9(Diameter of through holes) 2.54 2.54 2.54 2.54 1.2 0.5 60 6- 1.8(Diameter of lands) 15.2 unit(mm) unit(mm) FPN-R 4 0.2 8 0.8 Pressure port 2.2 3 14 R1.5 4 5 6 3 2 4.5 1 15.24(600mil) 5 max 15 6 4 5 12 C0.5 1 2 0.6 Vent hole 3 Terminal leads Recommended footprint for PCB 2.54 2.54 6- 0.9(Diameter of through holes) 6- 1.8(Diameter of lands) 2.54 2.54 60 1.2 0.5 Labelled faceplate 2.8 6.8 15.2 2 unit(mm) FPN,FGN-6 Data sheet Sensing element/Gauge Outline dimensions unit(mm) FGN-6 2.54 2.54 0.8 Pressure port 2 6 5 3 7 1 4 3 7 Vent hole Labelled faceplate 6 5 0.5 Recommended footprint for PCB 2-R0.5 4 1 Projections 2- 1(Holes for projections) 1.4 1.7 1 2 Land-pads 3 6.2 10.3 Projections 2.54 2.54 0.8 MA 0.25 X. 15 3.5 9.5 6 Index 6.2 9.4 unit(mm) Connection diagram unit(mm) FPN, FGN-6 i 1.5mA 2 Output voltage R2 Constant current source R1 1 3 6 R3 R4 5 1 VR0 6 Zero balancing trimmer (VR0) is available. VR0 :200 Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538 3 E-mail : [email protected]