FPM,FHM Data sheet

FPM,FHM Data sheet
Sensing element/Gauge
Features
Applications
. Dual-In-line-Package(DIP)or Horizontal pressure port, Easy
. Industrial instrumentation
. Pressure switch, Pneumatic device
to mount on PCB
. Vacuum pressure measurable
. Non-corrosive liquid measurable(FPMC/FHMC available)
. Medical device
. Turbo boost pressure measurement for Automotive system
Part number for ordering
FPM C - 07P G R
Model
FPM
FHM
Terminal leads direction(See Outline Diagram)
Rated pressure
(PSI)
No mark :
R
Pressure type
Available pressure media G : Gauge pressure
No mark : Non-corrosive gas only
C : Non-corrosive gas and liquid
Pressure type
:
Gauge pressure
FPM
FHM
Dual-In-line-Package(DIP)
Horizontal pressure port DIP
Model
Package configuration
Measurable pressure range(kPa)
13.79 13.79
34.47 34.47
48.26 48.26
98.07 103.4
98.07 206.8
98.07 344.7
98.07 482.6
98.07 827.4
FPM-02PG
FPM-05PG
FPM-07PG
FPM-15PG
FPM-30PG
FPM-50PG
FPM-70PG
FPM-120PG
FPM-02PGR
FPM-05PGR
FPM-07PGR
FPM-15PGR
FPM-30PGR
FPM-50PGR
FPM-70PGR
FPM-120PGR
FPMC-02PG
FPMC-05PG
FPMC-07PG
FPMC-15PG
FPMC-30PG
FPMC-50PG
FPMC-70PG
FPMC-120PG
Part number for ordering
FPMC-02PGR
FHM-02PG
FPMC-05PGR
FHM-05PG
FPMC-07PGR
FHM-07PG
FPMC-15PGR
FHM-15PG
FPMC-30PGR
FHM-30PG
FPMC-50PGR
FHM-50PG
FPMC-70PGR
FHM-70PG
FPMC-120PGR
FHM-120PG
FHM-02PGR
FHM-05PGR
FHM-07PGR
FHM-15PGR
FHM-30PGR
FHM-50PGR
FHM-70PGR
FHM-120PGR
FHMC-02PG
FHMC-05PG
FHMC-07PG
FHMC-15PG
FHMC-30PG
FHMC-50PG
FHMC-70PG
FHMC-120PG
FHMC-02PGR
FHMC-05PGR
FHMC-07PGR
FHMC-15PGR
FHMC-30PGR
FHMC-50PGR
FHMC-70PGR
FHMC-120PGR
Specifications
Model/Rated pressure
02PG
05PG
07PG
15PG
30PG
50PG
70PG
Accuracy
Recommended operating conditions
Pressure type
Gauge pressure
13.79
34.47
48.26
103.4
206.8
344.7
482.6
Rated pressure
0.141
0.352
0.492
1.055
2.109
3.516
4.922
13.79
34.47
48.26
98.07
98.07
98.07
98.07
Measurable pressure range
13.79
34.47
48.26
103.4
206.8
344.7
482.6
Pressure media
FPM, FHM : Non-corrosive gas only, FPMC, FHMC : Non-corrosive gas and liquid
Excitation current(Constant)
1.5
Absolute maximum rating
Maximum load pressure
Twice of rated pressure
Maximum excitation current
3
Operating temperature
20 100
Storage temperature
40 120
Operating humidity
30 80(No dew condensation)
Electric performances/characteristics(Excitation current I=1.5mA constant, Ambient temperature Ta=25 )
Full scale span voltage
60 140
Offset voltage
20
Bridge impedance
4000 6000
Mechanical response time
2(For the reference)
Temperature sensitivity of offset(TSO)
5
Temperature coefficient of sensitivity(TCS)
2.5
Linearity
0.5
0.3
0.5
Pressure hystersis
0.4
0.2
Please consult us available liquid pressure media when you choose the C models.
1
120PG
unit
827.4
8.437
98.07
827.4
kPa
kg/cm2
kPa
mADC
1.5times of rated pressure
mADC
RH
mV
mV
0.6
0.4
msec
FS/0 50
FS/0 50
FS
FS
FPM,FHM Data sheet
Sensing element/Gauge
Outline dimensions
unit(mm)
FPM
8
2.2
5
4
5
6
3
2
1
C0.5
3
2
4
3
14
1
4.5
0.6
Vent hole
R1.5
15.24(600mil)
6
Pressure port
0.8
max 15
5
0.2
4
12
Terminal leads
Labelled faceplate
6.8
2.8
Recommended footprint for PCB
6- 0.9(Diameter of through holes)
2.54 2.54
2.54 2.54
1.2
0.5
60
6- 1.8(Diameter of lands)
15.2
unit(mm)
unit(mm)
FPM-R
4
0.2
8
0.8
Pressure port
2.2
3
14
R1.5
4
5
6
3 2
4.5
1
15.24(600mil)
5
max 15
6
4
5
12
C0.5
1
2
0.6
Vent hole
3
Terminal leads
Recommended footprint for PCB
2.54 2.54
6- 0.9(Diameter of through holes)
6- 1.8(Diameter of lands)
2.54 2.54
60
1.2
0.5
Labelled faceplate
2.8
6.8
15.2
2
unit(mm)
FPM,FHM Data sheet
Sensing element/Gauge
Outline dimensions
unit(mm)
2.54 2.54
1
2
3
6
5
4
5.5
FHM
Pressure port
(14)
0.25
1
0.6
3.4
2.6
7.6
3.2
15
6
10.15
1.2
Vent hole
8
Labelled faceplate
6
5
Recommended footprint for PCB
4
6- 1(Diameter of through holes)
1
2
2.54 2.54
8
6- 1.8(Diameter of lands)
10
3
unit(mm)
2.54 2.54
FHM-R
2
3
6
5
4
5.5
1
unit(mm)
Pressure port
(14)
1.2
4.7
2.6
3.4
(7.6)
1.55
3.2
1
6
0.6
0.25
Recommended footprint for PCB
8
Labelled faceplate
6
5
6- 1(Diameter of through holes)
4
2.54 2.54
8
6- 1.8(Diameter of lands)
1
15
Vent hole
10.16
1
2
10
3
3
unit(mm)
FPM,FHM Data sheet
Sensing element/Gauge
Connection diagram
unit(mm)
FPM, FHM
i
1.5mA
2
Output voltage
R2
Constant
current
source
R1
1
3
6
R3
R4
5
1
VR0
6
Zero balancing trimmer (VR0) is available.
VR0 :200
Note ; Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us.
Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538
4
E-mail : [email protected]