PDF

FPM Data sheet
Sensing element/Gauge
■Features
Dual-in-line package (DIP)
■Ordering Information
FPM-07P
G R
Terminal leadsdirection
Model
Rated Pressure
(PSI)
No Mark:
Pressure type
G:Gauge Pressure
R :
Weight
(grams)
RoHS compliance
1.1
Measurable pressure
range(kPa)
-13.79 to 13.79
-34.47 to 34.47
-48.26 to 48.26
-98.07 to 103.4
-98.07 to 206.8
-98.07 to 344.7
-98.07 to 482.6
-98.07 to 827.4
Part number
FPM-02PG
FPM-05PG
FPM-07PG
FPM-15PG
FPM-30PG
FPM-50PG
FPM-70PG
FPM-120PG
FPM-02PGR
FPM-05PGR
FPM-07PGR
FPM-15PGR
FPM-30PGR
FPM-50PGR
FPM-70PGR
FPM-120PGR
■Specifications
Model
02PG
Recommended operating conditions
Pressure type
Rated pressure
Measurable pressure range
Temperature range
Pressure media
Excitation current (Constant)
13.79
-13.79
to 13.79
05PG
07PG
34.47
-34.47
to 34.47
48.26
-48.26
to 48.26
15PG
30PG
50PG
Gauge pressure
103.4
206.8
344.7
-98.07
-98.07
-98.07
to 103.4 to 206.8 to 344.7
0 to 50
Non-corrosive gases only (No liquid)
1.5
Absolute maximum rating
Maximum load pressure
Twice of rated pressure
3.0
-20 to 100
-40 to 120
30 to 80 (Non dew condition)
Electric characteristics (Drive Current 1.5mA constant ,ambient temperature Ta=25deg.C)
Output span voltage
60 to 140 (at 0kPa to rated pressure)
Offset voltage
+/-20 (at 0kPa)
Bridge resistance
4000 to 6000
Response time
2 (for the reference)
Accuracy
TSO*
+/-5
TCS*
2.5
Linearity
+/-0.5
+/-0.3
Pressure hysteresis
+/-0.4
+/-0.2
70PG
120PG
482.6
-98.07
to 482.6
827.4
-98.07
to 827.4
1
kPa
kPa
deg.C
mADC
1.5 times
of rating
pressure
mADC
deg.C
deg.C
%RH
Maximum excitation current
Operating temperature
Storage temperature
Operating humidity
*TSO : Temperature sensitivity of offset voltage(Temperature range from 0-50 deg.C)
*TCS : Temperature coefficient of output span voltage(Temperature range from 0-50 deg.C)
Unit
mV
mV
Ω
msec.
%FS/050deg.C
+/-0.5
+/-0.6
+/-0.4
%FS
%FS
FPM Data sheet
Sensing element/Gauge
P1= 0 kPa
P2= 1/2 x P3 (kPa)
P3= reted pressure (kPa)
T1= 0 deg.C
T2= 25 deg.C
T3= 50 deg.C
Offset voltage (mV)
Voff = V(P1,T)
Voff(0) = V(P1,T1)
Voff(25) = V(P1,T2)
Voff(50) = V(P1,T3)
Output voltage at full scale (mV)
Vfs = V(P3,T)
Vfs(0) = V(P3,T1)
Vfs(25) = V(P3,T2)
Vfs(50) = V(P3,T3)
Output span voltage (mV)
SV = Vfs - Voff
SV(0) = Vfs(0) - Voff(0)
SV(25) = Vfs(25) - Voff(25)
SV(50) = Vfs(50) - Voff(50)
Temperature sensitivity of offset voltage (%FS)
TSO = {LARGER ONE} / SV(25) x 100
LARGER ONE = larger absolute value which of {Voff(0)-Voff(25)} and {Voff(50)-Voff(25)}
Temperature coefficient of output span voltage (%FS)
TCS = {max[SV(0),SV(25),SV(50)] - min[SV(0),SV(25),SV(50)] } / SV(25) x 100
Linearity (%FS)
NL = {V(P2,T2) - [Voff(25)+Vfs(25)]/2 } / SV(25) x 100
Pressure hysteresis (%FS)
Phys = {Voff’(25) - Voff(25) } / SV(25) x 100
Voff’(25) : Output voltage against P1 after stressing by P3 pressure.
2
FPM Data sheet
Sensing element/Gauge
■Outline dimensions■
3
FPM Data sheet
Sensing element/Gauge
■Connection diagram■
■Output characteristics■
<02PG~07PG>
<15PG~120PG>
↑Output voltage(mV)
↑Output voltage(mV)
Output span
voltage
Offset voltage
-Rated pressure
Offset voltage
-98.07kPa
0kPa
0kPa
Rated pressure
→Pressure(kPa)
Rated pressure
→Pressure(kPa)
Atomospheric
pressure
Note ;
Output span
voltage
Atomospheric
pressure
Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
Please keep the sensors sealed using static shielding bags on storage.The pins of the sensor are plated by Ag.
If the sensors expose to an atmosphere, the pins will be black by sulfuration.
Please set Zero-calibration function up your products. The offset voltage may be shifted some mechanical stress
such as mounting, installation and etc. over longtime using.
If you have any questions regarding technical issues or specifications, please contact us.
Fujikura Ltd. Sensor Department
5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072
E-mail : [email protected]