Edco CAT6-POE Series Installation Manual (IO-50141)

Power Switching & Controls
For Business-Critical ContinuityTM
Edco CAT6-POE Series
CAT6 Power-Over-Ethernet
The Edco CAT6-POE Series is designed to work on Category 6 Power-Over-Ethernet
transmission line applications and is ideal for protecting expensive computer and
video equipment from damaging surges and transients.
Transmission lines provide easy access for transients to enter a facility putting vital
equipment at risk. The Edco CAT6-POE-I is available with an isolated ground to be
used at the equipment end in order to prevent circulating ground currents.
Up to four Edco CAT6-POEs can be installed using optional Edco C6-MP4
mounting bracket.
General Technical Specifications
CAT6-POE
CAT6-POE-I
Operating Voltage
48 VDC
DC Breakover Voltage
68 VDC
0.75 Amps per Pin Continuous
Peak Surge Current
10kA
Two Port Series
Modes of Protection
All Lines (1-8) Protected (L-L) and (L-G)
Signal High-Low; High-Ground; Low-Ground
Transmission Speeds
10BaseT; 100BaseT; 1000BaseT
SPD Technology
Input/Output Connection
CAT 5 Output Cable
Ground Terminal
Operating Temperature
Dimensions
Material
Mounting
Weight
Certification
Warranty
GDT; PTC; SAD
RJ-45 Jacks (Shielded)
RJ-45 Jacks (Isolated)
Shielded RJ-45, 7.0 (.18M)
Unshielded RJ-45, 7.0 (.18m)
10-32 Stud
10-32 Stud (Isolated)
-40°C to +85°C
DC over ethernet all pins
Optional mounting bracket
< 0.1 dB
Topology
Exceeds Category 6 transmission values
Three stage hybrid circuit
Operating Current*
Insertion Loss
Features
(operating current adjusted to 40% @ +85°C)
5.4” (L) x 1.6” (W) x 1.7” (H)
Aluminum
Flange
5 oz
UL 497B Listed, Tested to IEC 802.11
(Complies to IEEE 802.3AT and 802.3AF)
5 Year
*For applications requiring higher Operating Currents, parallel connections can be utilized.
See installation information on Page 2.
5 year warranty
Installation
1. Mount device as close as possible to protected equipment using #6 screws and mounting holes provided in flanges .
2. Run supply cable with RJ-45 connector to input side of device.
3. Use CAT5 output cable (provided) to connect from the output of the device to protected equipment.
4. Attach #10 ground wire using 10-32 ring terminal (not provided) to 10-32 ground stud on top of device,
connect opposite end of wire to "building approved ground". Wire should be short and straight as possible.
Optional Mounting Bracket, (Sold Separately): Part Number: C6-MP4
Bracket accommodates up to four CAT6-POE surge protectors. Bracket’s
ground lug allows all devices to share one single ground connection.
* For applications requiring higher
Operating Currents, input
connections can be paralleled to
meet the desired rating.
Emerson Network Power.
The global leader in enabling
Business-Critical ContinuityTM.
AC Power
Embedded Computing
Infrastructure Management & Monitoring
Thermal Management
Connectivity
Embedded Power
Outside Plant
Racks and Integrated Cabinets
DC Power
Industrial Power
Power Switching & Controls
Services
Emerson Network Power Contact Information
www.EmersonNetworkPower.com/Surge
Headquarters
Surge Protection
100 Emerson Parkway
Binghamton, NY 13905
T: (607) 721-8840
T: (800) 288-6169
F: (607) 722-8713
E: [email protected]
IO-50141 11/13 Rev. 5 Printed in USA
Business-Critical Continuity, Emerson Network Power and the Emerson Network Power
logo are trademarks and service marks of Emerson Electric Co. ©2013 Emerson Electric Co.