Edco 5W8-30 Installation Manual (IO-50108)

Edco 5W8-30
Two Pair Data/Signal Line Power
The Edco 5W8-30 is an access control protection module designed for typical
Wiegand outputs for access devices. This is a 5-wire module that accommodates
low voltage data lines for 5 VDC circuits. Fifth wire power protection will allow up
to 24 VDC.
In addition, sneak and fault currents are mitigated with resettable fuses (PTCs).
The PTCs increase resistance several orders of magnitude when over-currents
exceed safe levels. A normal state resumes when over-currents are removed. The
ability to self restore in this manner significantly increases suppressor performance
and survivability.
General Technical Specifications
EDCO PCB1B-WKEY BASE SOLD SEPARATELY
Operating Voltage
5 VDC (data) & 24 VDC (power)
Clamping Voltage
8 VDC (data) & 30 VDC (power)
Operating Current
0.15 A
Peak Surge Current
Frequency Range
Insertion Loss
SPD Technology
Connection Type
Operating Temperature
Dimensions (in / mm)
Weight (oz / kg)
Warranty
Data = 125 A (10 x 1000 μs)
Power = 500 A (8 x 20 μs)
0 to 20 MHz
< 0.15 dB at 20 MHz
MOV, SAD, w/ Series PTC
Terminal block w/ compression lugs
Terminals accept up to 10 AWG
-40°C to +85°C
2.0˝ H x 1.0˝ W x 2.5˝ L
[50.8 x 25.4 x 63.5 mm]
(5W8-30 + PCB1B-WKEY base)
1 oz [0.03 kg]
5 years
Caution
Do not place this product in service on any signal line capable of supplying more than 5 Amps continuously.
Attention
Ne pas placer ce produit dans le service sur une ligne de signal capable de fournir en permanence plus de
5 ampères.
Features
■■ Automatic recovery
■■ Fast response time
■■ Resettable fusing — PTCs
■■ Plug-in module
■■ Data and power protection combined
■■ Sneak/fault current protection ■
(data only)
■■ Silicon avalanche technology
■■ Requires Edco PCB1B-WKEY base
■■ PC462 PTU (Pass Thru Unit) available for troubleshooting
■■ 5 year warranty
Installation Instructions
Terminal Assignments
DRAWING 1
PCB1B-WKEY
10 DC POWER − T-Tap Positive
Common Wire Here
From
Field
9
Unprotected
Data Pair 2
8
7
6
5
Unprotected
Data Pair 1
4
3
2
Protected
Data Pair 2
Protected
Data Pair 1
To
Electronics
2.4"
[60.96]
2.125"
[53.98]
1
1.0"
[25.40]
Ground Terminal 1 or 10 to Building Approved Ground (preferably AC Power safety ground).
DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance ■
with all applicable codes.
DRAWING 2
V DANGER!
Only qualified personnel should install or
service this system. Electrical safety precautions must be followed when installing
or servicing this equipment. To prevent risk
of electrical shock, turn off and lock out all
power sources to the unit before making
electrical connections or servicing.
Seulement le personnel qualifié doit installer
ou maintenir ce systéme. Des précautions
de sécurité en électricité doivent être suivis
lors de l’installation ou de la maintenance
de cet equipement. Pour eviter tout risque
de choc électrique, débranchez et verouiller
toutes les sources d’alimentation de cet
equipement avant de.
PCB1B-WKEY
Emerson Network Power Contact information
www.EmersonNetworkPower.com/Surge
Surge Protection
100 Emerson Parkway
Binghamton, NY 13905
T: (607) 721-8840
T: (800) 288-6169
F: (607) 722-8713
E: [email protected]
IO-50108 5/14 Rev. 2 Printed in USA
Emerson Network Power, the Emerson Network Power logo and Edco are trademarks
and service marks of Emerson Electric Co. ©2014 Emerson Electric Co.
While every precaution has been taken to ensure accuracy and completeness herein, Emerson Network Power Surge Protection assumes no responsibility, and disclaims all liability, for damages
resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice.