IRF 302U120APD

Previous Datasheet
Index
Next Data Sheet
Bulletin I2031/A
70/300U(R)..D SERIES
Stud Version
STANDARD RECOVERY DIODES
Features
250A
Diffused diode
Wide current range
High voltage ratings up to 1600V
High surge current capabilities
Stud cathode and stud anode version
Typical Applications
Converters
Power supplies
Machine tool controls
High power drives
Medium traction applications
Major Ratings and Characteristics
Parameters
70/300U(R)..D
Units
250
A
145
°C
390
A
@ 50Hz
6550
A
@ 60Hz
6850
A
@ 50Hz
214
KA2s
@ 60Hz
195
KA2s
1200 to 1600
V
- 40 to 200
°C
IF(AV)
@ TC
IF(RMS)
IFSM
I 2t
V RRM range
TJ
To Order
case style
DO-205AB (DO-9)
Previous Datasheet
Index
Next Data Sheet
70/300U(R)..D Series
ELECTRICAL SPECIFICATIONS
Voltage Ratings
Type number
Voltage
Code
70/300U(R)..D
VRRM , maximum repetitive
peak reverse voltage
V
VRSM , maximum nonrepetitive peak rev. voltage
V
120
1200
1300
160
1600
1700
IRRM max.
@ TJ = TJ max.
mA
60
Forward Conduction
Parameter
I F(AV)
70/300U(R)..D
Units
Max. average forward current
250
A
@ Case temperature
145
°C
I F(RMS) Max. RMS forward current
390
A
I FSM
Max. peak, one-cycle forward,
6550
non-repetitive surge current
6850
I t
2
Maximum I t for fusing
t = 8.3ms
reapplied
t = 10ms
100% VRRM
5750
t = 8.3ms
reapplied
Sinusoidal half wave,
214
t = 10ms
No voltage
Initial TJ = TJ max.
t = 8.3ms
reapplied
t = 10ms
100% VRRM
t = 8.3ms
reapplied
A
KA2s
151
138
I √t
Maximum I √t for fusing
2
V F(TO)1 Low level value of threshold
voltage
V F(TO)2 High level value of threshold
voltage
r f1
r f2
KA √s
Max. forward voltage drop
t = 0.1 to 10ms, no voltage reapplied
(16.7% x π x I F(AV) < I < π x IF(AV) ), TJ = TJ max.
0.61
V
0.83
(I > π x IF(AV) ),TJ = TJ max.
0.75
(16.7% x π x IF(AV) < I < π x IF(AV) ), TJ = TJ max.
mΩ
High level value of forward
slope resistance
V FM
2140
2
Low level value of forward
slope resistance
DC @ 134°C case temperature
No voltage
195
2
180° conduction, half sine wave
t = 10ms
5500
2
Conditions
(I > π x IF(AV)),TJ = TJ max.
0.49
1.30
V
To Order
Ipk= 785A, TJ = 25°C, tp = 10ms sinusoidal wave
Previous Datasheet
Index
Next Data Sheet
70/300U(R)..D Series
Thermal and Mechanical Specifications
Parameter
70/300U(R)..D
TJ
Max. junction operating temperature range
-40 to 200
Tstg
Max. storage temperature range
-40 to 200
RthJC
Max. thermal resistance, junction to case
Max. thermal resistance, case to heatsink
0.08
T
Max. allowed mounting torque +0 -20%
37
DC operation
K/W
250
Case style
Mounting surface, smooth, flat and greased
Not lubricated threads
Nm
28
Approximate weight
Conditions
°C
0.18
RthCS
wt
Units
Lubricated threads
g
DO-205AB (DO-9)
See Outline Table
∆RthJC Conduction
(The following table shows the increment of thermal resistence RthJC when devices operate at different conduction angles than DC)
Conduction angle
Sinusoidal conduction Rectangular conduction Units
180°
0.020
0.015
120°
0.024
0.025
90°
0.031
0.034
60°
0.045
0.047
30°
0.077
0.077
Conditions
TJ = TJ max.
K/W
Ordering Information Table
Device Code
1
-
2
3
-
4
-
5
6
-
7
-
8
9
-
300
U
F
R
160
A
Y
P
D
1
2
3
4
5
6
7
8
9
300
= Standard 300U device
70
= Standard 70U device
302 = 300U Top Threaded version
72
= 70U Top Threaded version
U
= Essential Part Number
F
= Flat Base (with Pinch Bolt)
None = Normal Stud
R
= Stud Reverse Polarity (Anode to Stud)
None = Stud Normal Polarity (Cathode to Stud)
Voltage code: Code x 10 = VRRM (See Voltage Ratings table)
A
= Essential Part Number only for 300U Series
None = 70U Series
Y
= European Lead
None = Standard Lead
P
= Forward Selection (1.045V < VFM < 1.125V, IFM = 470A, TJ = 25°C)
D
= Diffused diode
To Order
Previous Datasheet
Index
Next Data Sheet
70/300U(R)..D Series
Outline Table
GLASS-METAL SEAL
DIA. 8.5 (0.33) NOM.
MAX.
MAX.
195 (7.68) MAX. (European lead)
28 (1.10)
21 (0 .83)
145 (5.71) MAX. (Standard lead)
21 (0.83)
MA X.
16.7 (0.66) MAX.
70/300U
DO-205AB (DO-9)
GLASS-METAL SEAL
16.7 (0.66) MAX.
DIA. 8.5 (0.33) NOM.
MAX.
195 (7.68) MAX. (European lead)
28 (1.10)
70/300UF
DO-205AB (DO-9)
Flat Base
135 (5.31) MAX. (Standard lead)
2 1 (0.83)
MAX.
3 (0.12)
3 2 (1.26)
3/4"-16UNF-2A
All dimensions in millimeters (inches)
To Order
3 (0.12)
32 (1.26)
36 (1.41)
Previous Datasheet
Index
Next Data Sheet
70/300U(R)..D Series
Outline Table
Pinch Bolt
35-0066
41 (1.61)
24
(0.94)
GLASS-METAL SEAL
(0.47)
20
(0.78)
2.4
(0.09)
27.3 (1.07) NOM.
DIA. 11.25 (044)
8.8 (0.34)
MAX.
5.5 (0.21) DIA.
13
(0.51)
50 (1.97) MAX.
12
11.19
(0.44) DIA.
6
(0.23)
9 (0.35) ±
0.1 (0.004)
DIA.
36 (1.41)
16
(0.62)
33 (1.29)
60 (2.36)
7 (0.27)
72/302UF
IR Case Style B26
Flat Bse
48 (1.88)
All dimensions in millimeters (inches)
GLASS-METAL SEAL
63 (2.48)
55 (2.17)
72/302U
IR Case Style B26
21 (0.83) MAX.
76 (2.99) MAX.
12.7 (0.5)
MIN.
3/8"-24UNF-2A
16 (0.63)
32 (1.26)
3/4"-16UNF-2A
To Order
FULL RAD.
DIA.
50 (1.96)
24
(0.94)
27.6 (1.80)
32 (1.26)
Spring Clamp
K41-0232
Previous Datasheet
Index
Next Data Sheet
70/ 300U(R)..D Series
RthJC (DC) = 0.18 K/ W
180
Conduction Angle
160
140
30°
120
50
100
60° 90°
120°
180°
150 200 250
300
350
70U/ 300U(R)..D Series
RthJC (DC) = 0.18 K/ W
190
180
170
Conduction Period
160
150
140
30°
130
60°
90°
120°
120
180°
DC
110
0
100
200
300
400
Average Forward Current (A)
Average Forward Current (A)
Fig. 1 - Current Ratings Characteristics
Fig. 2 - Current Ratings Characteristics
400
K/
W
1
0.
K/
W
W
K/
0.4
ta
el
-D
250
0.3
=
300
0.
2
A
hS
180°
120°
90°
60°
30°
350
Rt
K/
W
0.5
K/
W
RMS Limit
200
R
Maximum Average Forward Power Loss (W)
0
200
Maximum Allowable Case Temperature (°C)
200
0.7
K/ W
150
1 K/
Conduction Angle
W
1.5
K/
100
70/ 300U(R)..D Series
TJ = 200°C
50
W
3 K/ W
0
0
50
100
150
200
250
300
25
350
Average Forward Current (A)
50
75
100
125 150 175
200
Maximum Allowable Ambient Temperature (°C)
Fig. 3 - Forward Power Loss Characteristics
500
DC
180°
120°
90°
60°
30°
200
Conduction Period
150
70/ 300U(R)..D Series
TJ = 200°C
100
50
R
RMSLimit
K/
W
ta
el
-D
250
0.
3
W
K/
300
0.
2K
/W
1
0.
350
=
400
A
hS
450
Rt
Maximum Average Forward Power Loss (W)
Maximum Allowable Case Temperature (°C)
70/300U(R)..D Series
0.
5K
/W
0.7
K/ W
1 K/
W
1.5 K/
W
3 K/ W
0
0
100
200
300
400
Average Forward Current (A)
25
500
50
75
100
125
150
175
200
Maximum Allowable Ambient Temperature (°C)
Fig. 4 - Forward Power Loss Characteristics
To Order
500
Previous Datasheet
Index
Next Data Sheet
Peak Half Sine Wave Forward Current (A)
6000
At Any Rated Loa d Condition And With
Ra te d VRRM App lied Following Surg e.
5500
Initial TJ = 200°C
@60 Hz 0.0083 s
@50 Hz 0.0100 s
5000
4500
4000
3500
3000
2500
2000
70/ 300U(R)..D Series
1500
1
10
100
7000
Maximum Non Re petitive Surg e Curre nt
Versus Pulse Tra in Dura tion.
Initial TJ= 200°C
No Volta ge Re app lied
Rated VRRM Re app lied
6500
6000
5500
5000
4500
4000
3500
3000
2500
2000
70/ 300U(R)..D Series
1500
0.01
0.1
Number Of Equa l Amplitude Half Cyc le Current Pulses (N)
Fig. 6 - Maximum Non-Repetitive Surge Current
Instantaneous Forward Current (A)
10000
1000
TJ = 25°C
TJ = 200°C
100
70/ 300U(R)..D Series
10
0
0.5
1
1.5
2
2.5
3
Instantaneous Forward Voltage (V)
Fig. 7 - Forward Voltage Drop Characteristics
1
Stea d y Sta t e Va lue
0.1
RthJC= 0.18 K7W
(DC Op era tion)
0.01
70/ 300U(R)..D Se ries
0.001
0.0001
0.001
0.01
1
Pulse Train Duration (s)
Fig. 5 - Maximum Non-Repetitive Surge Current
Tra nsie nt Therm al Im p eda n ce Z thJC (K/ W)
Peak Half Sine Wave Forward Current (A)
70/300U(R)..D Series
0.1
1
10
Sq ua re Wave Pulse Dura tio n (s)
Fig. 8 - Thermal Impedance Z thJC Characteristic
To Order