NH12

PRODUCT DATASHEET
Asia Pacific Region
+852-31026623
ENERGIZER NH12-500
Specifications
Industry Standard Dimensions
(millimeters)
10.50
9.50
AAA
Classification:
Chemical System:
Rechargeable
Nickel-Metal Hydride (NiMH)
Designation:
Nominal Voltage:
Rated Capacity:
IEC-HR03
1.2 Volts
500 mAh (to 1.0 volts)
Based on 100 mA (0.2C) discharge rate
Typical Weight:
Typical Volume:
Jacket:
12.0 grams
3.8 cubic centimeters
Plastic Label
0.80
Minimum
3.80
Maximum
Internal Resistance:
The internal resistance of the cell varies
with state of charge, as follows:
Cell Charged
Cell 1/2 Discharged
100 milliohms
120 milliohms
(tolerance of ±20% applies to above values)
44.50
43.30
AC Impedance (No Load):
The impedance of the charged cell varies
with frequency, as follows:
4.30
Minimum
Frequency (Hz)
Typical Discharge Characteristics
1000
Typical Performance at 21ºC
Cell Voltage
1.4
1.3
100 mA
(0.2C)
1.1
1.0
Above values based on AC current set at 1.0 ampere.
Value tolerances are ±20%.
50 mA
(0.1C)
1.2
Operating and Storage Temperatures:
To maintain maximum performance, observe the following
general guidelines regarding environmental conditions.
0.9
0
3
6
Hours of Discharge
9
12
Typical Performance at 21ºC
1.4
Cell Voltage
Impedance (milliohms)
(Charged Cell)
35
1.3
1.2
1.1
1.0
0ºC to 40ºC
0ºC to 50ºC
-20ºC to 30ºC
65±20%
Operating at extreme temperatures,
will significantly impact battery cycle life.
0.25 A
(0.5C)
0.5 A
(1.0C)
1.0 A
(2.0C)
Charge:
Discharge:
Storage:
Humidity:
0.9
0.0
0.5
1.0
1.5
2.0
2.5
Hours of Discharge
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication.
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Engineering Data
Engineering Data
Form No. EBC - 8918AP-D
Page 1 of 1