ACT8512 48-Channel Analog Multiplexer Module
Radiation Tolerant & ESD Protected
www.aeroflex.com/mux
November 14, 2008
FEATURES
❑
❑
48 channels provided by six 16-channel multiplexers
Radiation performance
- Total dose:
150 krads(Si), Dose rate = 50 - 300 rads(Si)/s
- SEU:
Immune up to 90 MeV-cm2/mg
- SEL:
Immune by process design
❑
Full military temperature range
❑
Low power consumption < 90mW
❑
One address bus (A0-3) and three enable lines afford flexible organization
❑
All channel inputs protected by ±20V nominal transorbs
❑
Fast access time < 500ns typical
❑
Break-Before-Make switching
❑
High analog input impedance (power on or off)
❑
Designed for aerospace and high reliability space applications
❑
Packaging – Hermetic ceramic
- 96 leads, 1.32"Sq x 0.20"Ht quad flat pack
- Typical Weight 15 grams
❑
DSCC 5962-09203 SMD pending
Note: Aeroflex Plainview does not currently have a DSCC certified Radiation Hardened Assurance Program.
GENERAL DESCRIPTION
Aeroflex’s ACT8512 is a radiation tolerant, 48 channel multiplexer MCM (multi-chip module) with
electrostatic discharge (ESD) protection on all channel inputs.
The ACT8512 has been specifically designed to meet exposure to radiation environments. The multiplexer
is available in a 96 lead High Temperature Co-Fired Ceramic (HTCC) Quad Flatpack (CQFP). It is
guaranteed operational from -55°C to +125°C. Available screened in accordance with MIL-PRF-38534,
the ACT8512 is ideal for demanding military and space applications.
ORGANIZATION AND APPLICATION
The ACT8512 consists of six 16 channel multiplexers arranged as shown in the Block Diagram. The
ACT8512 design is inherently radiation tolerant.
The ACT8512 consists of forty-eight (48) channels addressable by bus A0~A3 in three 16 channel blocks,
each block enabled separately. Each block connects the addressed channel to two outputs, "Output" and
"Current". This technique enables selecting and reading a remote resistive sensor without the MUX
resistance being part of the measurement. For grounded sensors, this is done by passing current to the
sensor by means of the "Current" pin and reading the resultant voltage (proportional to the sensor
resistance) at the "Output" pin.
SCD8512 Rev D
SCD8512 Rev D 11/14/08
2
Aeroflex Plainview
GND
VREF
-VEE
+VEE
A0
A1
A2
A3
EN 16-31
CH 31
•
•
•
CH 16
EN 0-15
CH 15
•
•
•
CH 0
16
16
VR
VR
16
16
16
CH 47
•
•
•
CH 32
EN 32-47
CURRENT 16-31
OUTPUT 16-31
OUTPUT 0-15
16
VR
16
16
ACT8512 48 – CHANNEL ANALOG MUX BLOCK DIAGRAM
MUX 5
MUX 3
MUX 1
16
MUX 6
MUX 4
MUX 2
CURRENT 32-47
OUTPUT 32-47
CURRENT 0-15
ABSOLUTE MAXIMUM RATINGS 1/
Parameter
Range
Units
Case Operating Temperature Range
-55 to +125
°C
Storage Temperature Range
-65 to +150
°C
+20
-20
+7.5
V
V
V
<VREF +0.5
>GND -0.5
V
V
±18V
V
Supply Voltage
+VEE (Pin 44)
-VEE (Pin 46)
VREF (Pin 48)
Digital Input Overvoltage
VEN (Pins 5, 91, 92), VA (Pins 1, 3, 93, 95)
Analog Input Over Voltage
VS
Notes:
1/ All measurements are made with respect to ground.
NOTICE: Stresses above those listed under "Absolute Maximums Rating" may cause permanent damage to the device. These are stress rating
only; functional operation beyond the "Operation Conditions" is not recommended and extended exposure beyond the "Operation Conditions"
may affect device reliability.
RECOMMENDED OPERATING CONDITIONS 1/
Symbol
Parameter
Typical
Units
+VEE
+15V Power Supply Voltage
+15.0
V
-VEE
-15V Power Supply Voltage
-15.0
V
VREF
Reference Voltage
+5.00
V
VAL
Logic Low Level
+0.8
V
VAH
Logic High Level
+4.0
V
Notes:
1/ Power Supply turn-on sequence shall be as follows: -VEE, VREF, followed by +VEE.
DC ELECTRICAL PERFORMANCE CHARACTERISTICS 1/
(Tc = -55°C to +125°C, -VEE = -15V, VREF = +5.0V, +VEE = +15V - Unless otherwise specified)
Parameter
Supply Current
Symbol
+IEE
Conditions
VEN(0-47) = VA(0-3) = 0
-IEE
+ISBY
VEN(0-47) = 4V, VA(0-3) = 0 7/
-ISBY
Address Input Current
Enable Input Current
SCD8512 Rev D 11/14/08
Min
Max
Units
0
3
mA
-3
0
mA
0
3
mA
-3
0
mA
IAL(0-3)
VA = 0V
-6
6
μA
IAH(0-3)
VA = 5V
-6
6
μA
IENL(0-15)
VEN(0-15) = 0V
-2
2
μA
IENH(0-15)
VEN(0-15) = 5V
-2
2
μA
IENL(16-31)
VEN(16-31) = 0V
-2
2
μA
IENH(16-31)
VEN(16-31) = 5V
-2
2
μA
IENL(32-47)
VEN(32-47) = 0V
-2
2
μA
IENH(32-47)
VEN(32-47) = 5V
-2
2
μA
3
Aeroflex Plainview
DC ELECTRICAL PERFORMANCE CHARACTERISTICS 1/ (continued)
(Tc = -55°C to +125°C, -VEE = -15V, VREF = +5.0V, +VEE = +15V - Unless otherwise specified)
Parameter
Symbol
Positive Input Leakage
Current CH0-CH47
Negative Input Leakage
Current CH0-CH47
Output Leakage Current
OUTPUTS
(pins 25, 70 & 68)
CURRENTS
(pins 67 & 69)
Output Leakage Current
OUTPUTS
(pins 25, 70 & 68)
CURRENTS
(pins 67 & 69)
Conditions
ISOFFOUTPUT
+ISOFFCURRENT
-ISOFFOUTPUT
-ISOFFCURRENT
+IDOFFOUTPUT
+IDOFFCURRENT
Min
Max
Units
VIN = +10V, VEN = 4V, output and all unused MUX inputs
under test = -10V 2/ 3/
-100
+1000
nA
-100
+1000
nA
VIN = -10V, VEN = 4V, output and all unused MUX inputs
under test = +10V 2/, 3/
-100
+1000
nA
-100
+1000
nA
-100
+100
nA
-100
+100
VOUT = +10V, VEN = 4V, output and all unused MUX
inputs under test = -10V 3/, 4/
nA
-IDOFFOUTPUT
VOUT = -10V, VEN = 4V, output and all unused
MUX inputs under test = +10V 3/, 4/
-100
+100
-100
+100
+25°C
+125°C
-55°C
18.0
18.0
17.5
23.0
23.5
22.5
V
V
V
+25°C
+125°C
-55°C
-23.0
-23.5
-22.5
-18.0
-18.0
-17.5
V
V
V
-IDOFFCURRENT
VEN = 4V, all unused MUX inputs under test are
open. 3/
nA
nA
Input Clamped Voltage
CH0 - CH47
+VCLMP
Input Clamped Voltage
CH0 - CH47
-VCLMP
Switch ON Resistance
OUTPUTS
(pins 25, 70 & 68)
RDS(ON)(0-47)A
VIN = +15V, VEN = 0.8V, IOUT = -1mA
2/, 3/, 5/
200
1000
Ω
RDS(ON)(0-47)B
VIN = +5V, VEN = 0.8V, IOUT = -1mA
2/, 3/, 5/
200
1500
Ω
RDS(ON)(0-47)C
VIN = -5V, VEN = 0.8V, IOUT = +1mA
2/, 3/, 5/
200
2500
Ω
RDS(ON)(0-47)A
VIN = +15V, VEN = 0.8V, IOUT = -1mA
2/, 3/, 5/
200
1000
Ω
RDS(ON)(0-47)B
VIN = +5V, VEN = 0.8V, IOUT = -1mA
2/, 3/, 5/
200
1500
Ω
RDS(ON)(0-47)C
VIN = -5V, VEN = 0.8V, IOUT = +1mA
2/, 3/, 5/
200
2500
Ω
6/
Switch ON Resistance
CURRENTS
(pins 26, 67 & 69)
6/
Notes:
1/ Measure inputs sequentially. Ground all unused inputs of the device under test. VA is the applied input voltage to the address lines A(0-3).
2/ VIN is the applied input voltage to the input channels CH0-CH47.
3/ VEN is the applied input voltage to the enable lines En(0-15), En(16-31) and En(32-47).
4/ VOUT is the applied input voltage to the output lines OUTPUT(0-15), OUTPUT(16-31), OUTPUT(32-47), CURRENT(0-15) , CURRENT(16-31) and
CURRENT(32-47).
5/ Negative current is the current flowing out of each of the MUX pins. Positive current is the current flowing into each MUX pin.
6/ The ACT8512 cannot be operated with analog inputs from -15 to -5 volts.
7/ Not tested, guaranteed to the specified limits.
SWITCHING CHARACTERISTICS
(Tc = -55°C to +125°C, -VEE = -15V, VREF = +5.0V, +VEE = +15V -- Unless otherwise specified)
Parameter
Switching Test MUX
Symbol
tAHL
Conditions
RL = 10KΩ, CL = 50pF
tALH
tONEN
RL = 1KΩ, CL = 50pF
tOFFEN
SCD8512 Rev D 11/14/08
4
Min
Max
Units
10
1000
ns
10
1000
ns
10
1000
ns
10
1000
ns
Aeroflex Plainview
TRUTH TABLE (CH0 – CH15)
TRUTH TABLE (CH16 – CH31)
A3
A2
A1
A0
EN(0-15)
"ON" CHANNEL 1/
A3
A2
A1
A0
EN(16-31)
"ON" CHANNEL 1/
X
X
X
X
H
NONE
X
X
X
X
H
NONE
L
L
L
L
L
CH0
L
L
L
L
L
CH16
L
L
L
H
L
CH1
L
L
L
H
L
CH17
L
L
H
L
L
CH2
L
L
H
L
L
CH18
L
L
H
H
L
CH3
L
L
H
H
L
CH19
L
H
L
L
L
CH4
L
H
L
L
L
CH20
L
H
L
H
L
CH5
L
H
L
H
L
CH21
L
H
H
L
L
CH6
L
H
H
L
L
CH22
L
H
H
H
L
CH7
L
H
H
H
L
CH23
H
L
L
L
L
CH8
H
L
L
L
L
CH24
H
L
L
H
L
CH9
H
L
L
H
L
CH25
H
L
H
L
L
CH10
H
L
H
L
L
CH26
H
L
H
H
L
CH11
H
L
H
H
L
CH27
H
H
L
L
L
CH12
H
H
L
L
L
CH28
H
H
L
H
L
CH13
H
H
L
H
L
CH29
H
H
H
L
L
CH14
H
H
H
L
L
CH30
H
H
H
H
L
CH15
H
H
H
H
L
CH31
1/ Between CH0-15 and OUTPUT (0-15) and CURRENT (0-15).
1/ Between CH16-31 and OUTPUT (16-31) and CURRENT (16-31).
TRUTH TABLE (CH32 – CH47)
A3
A2
A1
A0
EN(32-47)
"ON" CHANNEL 1/
X
X
X
X
H
NONE
L
L
L
L
L
CH32
L
L
L
H
L
CH33
L
L
H
L
L
CH34
L
L
H
H
L
CH35
L
H
L
L
L
CH36
L
H
L
H
L
CH37
L
H
H
L
L
CH38
L
H
H
H
L
CH39
H
L
L
L
L
CH40
H
L
L
H
L
CH41
H
L
H
L
L
CH42
H
L
H
H
L
CH43
H
H
L
L
L
CH44
H
H
L
H
L
CH45
H
H
H
L
L
CH46
H
H
H
H
L
CH47
1/ Between CH32-47 and OUTPUT (32-47) and CURRENT (32-47)
SCD8512 Rev D 11/14/08
5
Aeroflex Plainview
Address Lines
(A0 - A3)
4.0V
50%
0.8V
11.6V MIN
50%
MUX Output
0V
t AHL
Definition of t AHL
Address Lines
(A0 - A3)
4.0V
50%
0.8V
11.6V MIN
MUX Output
50%
0V
t ALH
Definition of t ALH
4.0V
EN Lines
50%
0.8V
~3V to 12.5V
MUX Output
50%
0V
tONEN
tOFFEN
Definition of tONEN and tOFFEN
NOTE: f = 10KHz, Duty cycle = 50%.
ACT8512 SWITCHING DIAGRAMS
SCD8512 Rev D 11/14/08
6
Aeroflex Plainview
PIN NUMBERS & FUNCTIONS
ACT8512 – 96 Leads Ceramic QUAD Flat Pack
Pin #
Function
Pin #
Function
Pin #
Function
1
A2
33
CH11
65
CH33
2
NC
34
GND
66
CH32
3
A3
35
CH12
67
Output I(32-47)
4
NC
36
GND
68
Output V(32-47)
5
EN 0-15
37
CH13
69
Output I(16-31)
6
NC
38
GND
70
Output V(16-31)
7
CH0
39
CH14
71
GND
8
GND
40
GND
72
GND
9
CH1
41
CH15
73
CH31
10
GND
42
GND
74
CH30
11
CH2
43
NC
75
CH29
12
GND
44
+VEE
76
CH28
13
CH3
45
NC
77
CH27
14
GND
46
-VEE
78
CH26
15
CH4
47
NC
79
CH25
16
GND
48
VREF
80
CH24
17
CH5
49
NC
81
CH23
18
GND
50
CASE GND
82
CH22
19
CH6
51
CH47
83
CH21
20
GND
52
CH46
84
CH20
21
CH7
53
CH45
85
CH19
22
GND
54
CH44
86
CH18
23
GND
55
CH43
87
CH17
24
GND
56
CH42
88
CH16
25
Output V(0-15)
57
CH41
89
GND
26
Output I(0-15)
58
CH40
90
GND
27
CH8
59
CH39
91
EN 32-47
28
GND
60
CH38
92
EN 16-31
29
CH9
61
CH37
93
A0
30
GND
62
CH36
94
NC
31
CH10
63
CH35
95
A1
32
GND
64
CH34
96
NC
NOTE: It is recommended that all "NC" or "no connect pin" be grounded. This eliminates or minimizes any ESD or
static buildup.
SCD8512 Rev D 11/14/08
7
Aeroflex Plainview
ORDERING INFORMATION
Model Number
Screening
DSCC SMD #
Package
ACT8512-S
Military Temperature, -55°C to +125°C,
Screened in accordance with MIL-PRF-38534, Class K
NA
QUAD Flat Pack
ACT8512-7
Commercial Flow, +25°C testing only
ACT8512-201-1S
In accordance with DSCC SMD
FLAT PACKAGE OUTLINE
5962-0920301KXC
1.150 ±.005
(23 Spaces at .050)
Tol Non-Cum
4 Sides
Pin 1
Pin 12
.200
MAX
Pin 85
Pin 84
Pin 13
.0165
±.003
1.320 SQ
MAX
Pin 36
(.400)
Pin 61
Pin 60
Pin 37
Note: Outside ceramic tie bars
not shown for clarity. Contact
factory for details.
.006
±.001
EXPORT CONTROL:
EXPORT WARNING:
This product is controlled for export under the International Traffic in
Arms Regulations (ITAR). A license from the U.S. Department of
State is required prior to the export of this product from the United
States.
Aeroflex’s military and space products are controlled for export under
the International Traffic in Arms Regulations (ITAR) and may not be
sold or proposed or offered for sale to certain countries. (See ITAR
126.1 for complete information.)
PLAINVIEW, NEW YORK
Toll Free: 800-THE-1553
Fax: 516-694-6715
INTERNATIONAL
Tel: 805-778-9229
Fax: 805-778-1980
NORTHEAST
Tel: 603-888-3975
Fax: 603-888-4585
SE AND MID-ATLANTIC
Tel: 321-951-4164
Fax: 321-951-4254
WEST COAST
Tel: 949-362-2260
Fax: 949-362-2266
CENTRAL
Tel: 719-594-8017
Fax: 719-594-8468
www.aeroflex.com
[email protected]
Aeroflex Microelectronic Solutions reserves the right to
change at any time without notice the specifications, design,
function, or form of its products described herein. All
parameters must be validated for each customer's application
by engineering. No liability is assumed as a result of use of
this product. No patent licenses are implied.
Our passion for performance is defined by three
attributes represented by these three icons:
solution-minded, performance-driven and customer-focused
SCD8512 Rev D 11/14/08