RHD5963 (7/15)

Preliminary
Standard Products
RadHard-by-Design
RHD5963 2.00 Volt Precision Voltage Reference
and Buffered Thermometer
www.aeroflex.com/RHDseries
July 27, 2015
FEATURES

Operating voltage range: 3 volts to 6 volts.

Radiation performance
- Total dose:
- ELDRS Immune
- SEL Immune
- Neutron Displacement Damage
> 1 Mrad(Si); Dose rate = 50 - 300 rads(Si)/s
> 100 MeV-cm2/mg
> 1014 neutrons/cm2

2.00V Precision Voltage Reference

Buffered Thermometer

Sleep Mode (EN = 0) disables all bias generators

Power at 5 volts < 7.5 mW

Full military temperature range

Designed for aerospace and high reliability space applications

Packaging – Hermetic Ceramic
 Hermetic Surface Mount Power
 5 Pads, .545"L x .296"W x .120"Ht
 Weight - 2.0 gm max

Aeroflex Plainview’s Radiation Hardness Assurance Plan is DLA Certified to MIL-PRF-38534, Appendix G.
GENERAL DESCRIPTION
Aeroflex’s RHD5963 is a radiation hardened, single supply, Voltage Reference and Buffered Thermometer
in 5-pad Power SMD Packages. The RHD5963 design uses specific circuit topology and layout methods to
mitigate total ionizing dose effects and single event latchup. These characteristics make the RHD5963
especially suited for the harsh environment encountered in Deep Space missions. It is guaranteed
operational from -55°C to +125°C. Available screened in accordance with MIL-PRF-38534 Class K, the
RHD5963 is ideal for demanding military and space applications.
The RHD5963 integrated circuit die is mounted directly to the metal signal pad providing optimum thermal
conduction to the printed circuit board bond sites.
The RHD5963 has an external enable signal (EN) which, when set low, enables a "Sleep Mode" that
disables all internal bias generators and sets both the Thermometer & Reference outputs to an OFF state
resulting in a reduced current consumption to below 600 nA.
SCD5963 Rev A
TABLE 1: ABSOLUTE MAXIMUM RATINGS
Parameter
Range
Units
Case Operating Temperature Range
-55 to +125
°C
Storage Temperature Range
-65 to +150
°C
Junction Temperature
+150
°C
Input Voltage
VIN - GND
+7.0
V
VIN +0.4, GND -0.4
V
Lead Temperature (soldering, 10 seconds)
300
°C
Thermal Resistance, Junction to Case,jc
3.5
°C/W
Enable (EN)
NOTICE: Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress rating only;
functional operation beyond the “Operation Conditions” is not recommended and extended exposure beyond the “Operation Conditions” may affect
device reliability.
TABLE 2: RECOMMENDED OPERATING CONDITIONS
Symbol
Typical
Units
Input Supply Voltage
3.0 to 5.0
V
EN - High
Output Enabled
70% VIN
V
EN - Low
Output Disabled
30% VIN
V
+VIN
Parameter
TABLE 3: ELECTRICAL PERFORMANCE CHARACTERISTICS
(TC = -55°C TO +125°C, +VIN = +5.0V, unless stated otherwise)
Parameter
Quiescent Supply Current 1/
Reference Output Voltage
Symbol
IINQ
VREF
Conditions
Min
Typ
Max
Units
EN = 1, No Load
-
1
1.5
mA
EN = 0
-
-
600
nA
No Load
1.96
2
2.04
No Load 2/
1.96
-
2.06
1.96
-
2.08
No Load 4/
1.96
-
2.10
No Load 1/
1.96
-
2.15
+25°C
No Load 3/
V
Reference Temperature Co 5/
REF TC
-
25
35
ppm/°C
Reference Change with
Temperature 6/
REFT
-
0.45
0.63
%
Long Term Stability 7/
VREF/TIME
-
-
100
ppm
-
-
0.2
%/mA
45
-
-
dB
Reference Load Regulation 1/
REFIL
Power Supply Rejection Ratio
1/
VREFPSRR
SCD5963 Rev A Preliminary 7/27/15
IOUT = 0 -to- 1 mA
2
Aeroflex Plainview
TABLE 3: ELECTRICAL PERFORMANCE CHARACTERISTICS (continued)
(TC = -55°C TO +125°C, +VIN = +5.0V, unless stated otherwise)
Parameter
Thermometer Output Voltage
Symbol
VTHERM
Conditions
Min
Typ
Max
No Load
0.80
1.0
1.20
No Load 2/
0.80
-
1.30
0.80
-
1.35
No Load 4/
0.80
-
1.40
No Load 1/
0.80
-
1.50
+25°C
No Load 3/
Units
V
Thermometer Temperature
Coefficient
THERMTC
7
10
11
mV/°C
Power Supply Rejection Ratio
1/
VTHERMPSRR
40
-
-
dB
Thermometer Output
Impedance 1/
THERMROUT
-
-
75
Ω
IOUT = 0 -to- 1 mA
Enable High Level Input Voltage
VIH
3.5
-
-
V
Enable Low Level Input Voltage
VIL
-
-
1.5
V
+25°C
-5
-
5
nA
+125°C
-50
-
50
nA
Enable Leakage Current
IIH, IIL
Reference
Short Circuit Current 8/
Io(sink)
REF to VCC
-25
-50
-75
nA
Io(source)
REF to GND
25
50
75
nA
Io(sink)
THERM to VCC
-25
-50
-75
nA
Io(source)
THERM to GND
25
50
75
nA
-
-
5
us
-
-
1
us
-
-
30
us
Thermometer
Short Circuit Current 8/
Switching Characteristics
VREF
Output Delay (Enabled)
TONEN
VTHERM
TONEN
VREF
Output Delay (Disabled)
TOFFEN
VTHERM
TOFFEN
Turn on Time 8/
TON
No Load, 50% points
No Load, 50% points
+25°C
+125°C
No Load, 50% points
No Load, 50% points
+25°C
+125°C
0.1% Settling, No Load
Notes:
1/ Specification derated to reflect Total Dose exposure to 1 Mrad(Si) @ +25°C.
2/ Specification derated to reflect Total Dose exposure to 100krad(Si) @ +25°C.
3/ Specification derated to reflect Total Dose exposure to 300krad(Si) @ +25°C.
4/ Specification derated to reflect Total Dose exposure to 500krad(Si) @ +25°C.
5/ Reference temperature coefficient is defined as the absolute value of the difference from the maximum and minimum voltage over the specified
temperature range, divided by the change in temperature and converted into ppm/°C.
6/ Reference change with temperature is defined as the absolute value of the difference from the maximum and minimum voltage over the specified
temperature range represented as a percentage.
7/ Not tested. Shall be guaranteed to specified limits after 1000hr life test
8/ Not tested. Shall be guaranteed by design, characterization, or correlation to other test parameters.
SCD5963 Rev A Preliminary 7/27/15
3
Aeroflex Plainview
FIGURE 1– VREF OUTPUT vs TEMPERATURE
FIGURE 2– VTHERM OUTPUT vs TEMPERATURE
SCD5963 Rev A Preliminary 7/27/15
4
Aeroflex Plainview
RHD5963 SIGNAL DEFINITIONS
Pad #
Pin 1
Epoxy Dot
(on side)
Signal
Definition
1
EN
Enable (Hi = outputs ON, Lo = OFF)
2
VIN
Input Voltage
3
VTHERM
Buffered Thermometer
4
VREF
2.00V Precision Voltage Reference
5
GND
Ground
.301
MAX
.095
4 Places
R.025 MAX
6 Places
.030 MIN
4
1
.005
.120
4 Places
.030
MIN
.550
MAX
5
.200
.005
.030
MIN
3
2
.150
4X R.020
.015
3 Places
.127
MAX
.005
.005
.286
NOTE: Package & Lid are electrically isolated from signal pads.
FIGURE 3 – PACKAGE OUTLINE — SURFACE MOUNT : SMD STYLE 5-PAD
SCD5963 Rev A Preliminary 7/27/15
5
Aeroflex Plainview
ORDERING INFORMATION
Model
DLA SMD #
Screening
RHD5963-7
-
Commercial Flow, +25°C testing only
RHD5963-S
-
Military Temperature, -55°C to +125°C
Screened in accordance with the individual Test Methods
of MIL-STD-883
RHD5963-201-1S
5962-1422103KYC
RHD5963-201-2S
5962-1422103KYA
RHD5963-901-1S
5962H1422103KYC
RHD5963-901-2S
5962H1422103KYA
Package
DLA SMD Pending
5-Pad
SMD
Power Pkg
DLA SMD and Radiation Certification Pending
EXPORT CONTROL:
This product is controlled for export under the U.S. Department of Commerce (DoC). A license may be required prior to the export
of this product from the United States.
www.aeroflex.com/HiRel
[email protected]
Datasheet Definitions:
Advanced
Preliminary
Datasheet
Product in Development
Shipping Non-Flight Prototypes
Shipping QML and Reduced HiRel
Aeroflex Plainview, Inc. reserves the right to make changes to any products and
services described herein at any time without notice. Consult Aeroflex or an authorized
sales representative to verify that the information in this data sheet is current before
using this product. Aeroflex does not assume any responsibility or liability arising out
of the application or use of any product or service described herein, except as expressly
agreed to in writing by Aeroflex; nor does the purchase, lease, or use of a product or
service from Aeroflex convey a license under any patent rights, copyrights, trademark
rights, or any other of the intellectual rights of Aeroflex or of third parties.
SCD5963 Rev A Preliminary 7/27/14
6
Our passion for performance is defined by three attributes.
Solution-Minded
Performance-Driven
Customer-Focused