400 Series 460 Surge Protective Device – Discrete 10-Mode Submittal Specification General Specifications Maximum Continuous Operating Voltage Short Circuit Current Rating (SCCR) Maximum Surge Current Rating Connection Types Operating Frequency Range EMI/RFI Noise Rejection UL 1449 Location Type UL1449 Nominal Discharge Current (In) Status Indication Certifications Discrete 10-Mode Option The 460 offers a Discrete “10-Mode” protection option, (up to 200kA/mode, 600kA/phase when adding L-N+L-G+L-L modes). This may be a requirement on some commercial projects based on performance advantage claims; including increased operational life, enhanced durability due to lower component stress, improved transient response and increased surge current sharing. We have a long history of achieving those same results with our standard mode/connection methods and configurations. However, for those projects that are specified with this requirement, the 460 is available in a Discrete 10-Mode construction format. IEC Class Standard Enclosure Warranty 120VAC 150%, all others 115% 200kAIC (“05”) 50kA Per Mode/150kA Per Phase (“10”) 100kA Per Mode/300kA Per Phase (“20”) 200kA Per Mode/600kA Per Phase Compression Lug/Terminal Block Rotary Disconnect Switch 47-63Hz 40dB Max (Type 1), 60dB Max (Type 2) Type 1 / Type 2 20kA Green/Red LED, Audible Alarm, Alarm Test/Silence Feature, Relay Alarm Contacts, N-G LED, Surge Event LED Surge Counter, ATDS ANSI/UL 1449 Third Edition Type 1 or Type 2; cUL CE, IEC61643-11 Class I/II NEMA Type 12/4 10 Years ANSI/UL 1449 Third Edition, Type 1 VPR’s Source Configuration SA, YA YC YD DB / DF / DG L-N 800V 1200V 1500V N/A L-G 800V 1200V 1500V 1200V / 1800V / 2000V Model Number Configurator 0 L N-G 800V 1200V 1500V N/A CUL Approvals _____________ 4 6 L-L 1200V 2000V 2500V 1200V / 2000V / 3000V For all applications requiring CUL approvals, change the SPD model number from a UL Type 1 (460xxxxxxxx1x) to a UL Type 2 (460xxxxxxxx2x) 1 S Advanced Transient Detection System Configuration & Voltage SA Single Phase, 3W+G (L1, L2, N, G) YA Three Phase WYE, 4W+G (L1, L2, L3, N, G) Three Phase WYE, 4W+G (L1, L2, L3, N, G) Three Phase WYE, 4W+G (L1, L2, L3, N, G) YC YD DB DF DG Three Phase Delta, 3W+G (L1, L2, L3, G) Three Phase Delta, 3W+G (L1, L2, L3, G) Three Phase Delta, 3W+G (L1, L2, L3, G) 120/240 VAC 120/208 VAC, 127/220 VAC 05 10 20 277/480 VAC, 254/440 VAC 346/600 VAC 220 VAC, 230 VAC, 240 VAC N R Additional Accessories Surge Rating 50kA Per Mode 150kA Per Phase 100kA Per Mode 300kA Per Phase 200kA Per Mode 600kA Per Phase Connection Type Compression Lug/Terminal Block Rotary Disconnect Switch 480 VAC 600 VAC E LL CL TG A Web-Based Power Quality Monitor Integrated within a Surge Protection Device S Standard X Consult Factory for additional source configurations, Surge Ratings, Monitoring Options, Enclosure Ratings, Etc. Monitoring Option Red & Green LEDs, Relay Alarm Contacts Audible Alarm, N-G LED & Surge Event LED Red & Green LEDs, Relay Alarm Contacts Audible Alarm, N-G LED & Surge Counter Advanced Transient Detection System See publication SL-70109, TS-70109 1.34 [34] C Real-Time Measurements Event Logging with Time/Date Stamp Embedded Web Page Ethernet, MODBUS, RS-485 Communications SPD Health Status - % Protection remaining LCD Display Dimensional Information Dimensional Information Surge A B C D E Weight Rating 50kA-150kA 12 12 6 10.75 10.88 21.0 lbs Per Mode [305] [305] [152] [273] [276] (9.5 kg) A 100 Emerson Parkway Binghamton, NY 13905 P (607) 721 8840 P (800) 288 6169 F (607) 722 8713 E [email protected] D 200kA Per Mode 16 14 8 16.75 12 35.0 lbs [406] [356] [203] [425] [305] (15.9 kg) Units with Advanced Transient Detection System monitoring option. Surge Rating 0.31 [8] B All A B C D E 16 16 8 16.75 12 [406] [406] [203] [425] [305] Weight see weights above SS-70113 Rev 2 1-15