GBU8J-U1 8A GLASS PASSIVATED ULTRA LOW VF BRIDGE RECTIFIERS - 600V PRIMARY CHARACTERISTICS VRRM 600V I(AV) 8.0A VF 0.89V I2t 166A2s TJ,Max 150℃ GBU(R) PACKAGE . ● Body Marking : GBU8J UL Mark Logo Marking Code VYM 8J GBU Date Code . Positive Electrodes V:Product Line Code Y:1-digit BC year code, 4-2014,5-2015…etc .. M:Month Code, Ex : 1-1,2-2,---10-O,11-N,12-D :ULTRA LOW VF FEATURES MECHANICAL DATA Surge overload rating -200 amperes Case:Molded plastic,GBU(R) peak Polarity:Shown above Ideal for printed circuit board Terminals :Plated terminals, Reliable low cost construction utilizing solderable per MIL-STD-750,Method molded plastic technique 2026 Moisture Sensitivity Level 1 Epoxy : UL94-V0 rated flame retardant MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Rating at 25℃ ambient temperature unless otherwise specified. Single phase, half wave ,60Hz, resistive or inductive load. For capacitive load, derate current by 20% CHARACTERISTICS SYMBOL GBU8-8 UNIT Maximum Recurrent Peak Reverse Voltage VRRM 600 V Maximum RMS Voltage VRMS 420 V Maximum DC Blocking Voltage VDC 600 V Maximum Average Forward (with heatsink Note 2) Rectified Current @ T C=100℃ (without heatsink) Peak Forward Surge Current I(AV) IFSM 8.3ms Single Half Sine-Wave 8.0 2.9 A 200 A 0.89 V Super Imposed on Rated Load (JEDEC Method) Maximum Forward Voltage at 4.0A DC Maximum DC Reverse Current @ TJ=25℃ at Rated DC Blocking Voltage @ T J=125℃ VF IR 10.0 500 μA I2t Rating for Fusing (t<8.3ms) I2t 166 A2s Typical Junction Capacitance Per Element (Note1) CJ 60 pF RθJC 2.2 ℃/W TJ -55 to +150 ℃ TSTG -55 to +150 ℃ Typical Thermal Resistance Operating Temperature Range Storage Temperature Range NOTES: 1.Measured at 1.0MHz and applied reverse voltage of 4.0V DC. 2.Device mounted on 75mm*75mm*1.6mm Cu plate heatsink. 2015.0ϳ www.willas.com.tw Rev.Ś0ϭ P1 GBU8J-U1 8A GLASS PASSIVATED ULTRA LOW VF BRIDGE RECTIFIERS - 600V FIG.2-MAXIMUM NON-REPETITIVE SURGE CURRENT PEAK FORWARD SURGE CURRENT, AMPERES AVERAGE FORWARD CURRENT AMPERES FIG.1-FORWARD CURRENT DERATING CURVE 10.0 WITH HEATSINK 8.0 6.0 WITHOUT HEATSINK 4.0 2.0 SINGLE PHASE HALF WAVE 60Hz RESISTIVE OR INDUCTIVE LOAD 0.0 0 20 40 60 100 80 120 140 200 PULSE WIDTH 8.3ms SINGLE HALF-SINE-WAVE (JEDEC METHOD) 150 100 50 0 1 10 5 2 CASE TEMPERATURE, °C 20 50 100 NUMBER OF CYCLETS AT 60Hz FIG.4-TYPICAL FORWARD CHARACTERISTICS FIG.3-TYPICAL JUNCTION CAPACITANCE 20.0 1000 INSTANTANEOUS FORWARD CURRENT, AMPERES CAPACITANCE,(pF) 10.0 100 10 TJ=25°C,f=1MHZ 1.0 1.0 10.0 1.0 0.1 TJ=25°C 0.01 100 0 REVERSE VOLTAGE,(VOLTS) 0.2 0.4 0.6 0.8 1.0 1.2 1.4 INSTANTANEOUS FORWARD VOLTAGE. VOLTS FIG.5-TYPICAL REVERSE CHARACTERISTICS INSTANTANEOUS REVERSE CURRENT ,(uA) 1000 TJ=125°C 100 TJ=100°C 10 TJ=50°C 1.0 TJ=25°C 0.1 0 20 40 60 80 100 PERCENT OF RATED PEAK REVERSE VOLTAGE,(%) 2015.0ϳ www.willas.com.tw Rev.Ś0ϭ P2 GBU8J-U1 8A GLASS PASSIVATED ULTRA LOW VF BRIDGE RECTIFIERS - 600V Outline Drawing GBU(R) .437(11.1) .430(10.9) .126(3.2)*45° CHAMFER .874(22.2) .860(21.8) .161(4.1) .134(3.4) .752(19.1) .720(18.3) .232(5.9) .213(5.4) .401(10.2) .392(9.80) .073(1.85) .057(1.45) .100(2.54) .085(2.16) .720(18.29) .680(17.27) .047(1.2) .035(0.9) .080(2.03) .065(1.65) .210 .190 (5.3) (4.8) .210 .190 (5.3) (4.8) .210 .190 (5.3) (4.8) .106(2.7) .091(2.3) .022(.56) .018(.46) Dimensions in inches and (millimeters) 2015.0ϳ .139(3.53) .133(3.37) www.willas.com.tw Rev.B-1 Rev.Ś0ϭ P3 GBU8J-U1 8A GLASS PASSIVATED ULTRA LOW VF BRIDGE RECTIFIERS - 600V Ordering Information: Device PN GBU8J-U1 (1)G(2)-WS Packing Tube Packing:20pcs/Tube; 1000pcs/Box Note: 1. Packing code: Empty is Tube Packing 2. RoHS product for packing code suffix ”G”, Halogen free product for packing code suffix "H" . ***Disclaimer*** WILLAS reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. WILLAS or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on WILLAS data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. WILLAS does not assume any liability arising out of the application or use of any product or circuit. This is the preliminary specification. WILLAS products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of WILLAS. Customers using or selling WILLAS components for use in such applications do so at their own risk and shall agree to fully indemnify WILLAS Inc and its subsidiaries harmless against all claims, damages and expenditures. 2015.0ϳ www.willas.com.tw Rev.Ś0ϭ P4