RS2505M-U1 25A GLASS PASSIVATED ULTRA LOW VF BRIDGE RECTIFIERS - 600V PRIMARY CHARACTERISTICS VRRM 600V I(AV) 25.0A VF 0.92V 2 It 508A s TJ,Max 150℃ RS-6M PACKAGE ● Body Marking Example Marking :RS2505M-8 UL Mark RS2505M-8 Marking Code 2 Date Code V Logo ~ ~ V:Product Lines Y:A.D. late code, EX : 4-2014,5-2015 M:Month, EX : 1-1,2-2,---10-O,11-N,12-D FEATURES + Rating to 600V PRV Case:Molded plastic,RS-6M Ideal for printed circuit board Polarity:Shown above Low forward voltage drop,high current Terminals :Plated terminals, capability solderable per MIL-STD-750,Method Reliable low cost construction utilizing 2026 molded plastic technique results in inexpensive product - MECHANICAL DATA ~ ~ Epoxy : UL94-V0 rated flame retardant Moisture Sensitivity Level 1 MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Rating at 25℃ ambient temperature unless otherwise specified. Single phase, half wave ,60Hz, resistive or inductive load. For capacitive load, derate current by 20% CHARACTERISTICS SYMBOL RS2505M-8 UNIT VRRM 600 V Maximum RMS Voltage VRMS 420 V Maximum DC Blocking Voltage VDC 600 V Maximum Recurrent Peak Reverse Voltage Maximum Average Forward (with heatsink Note 2) Rectified Current @ T C=100℃ (without heatsink) Peak Forward Surge Current 8.3ms Single Half Sine-Wave I(AV) 25.0 4.2 A IFSM 350 A VF 0.92 V Super Imposed on Rated Load (JEDEC Method) Maximum Forward Voltage at 12.5A DC Maximum DC Reverse Current @ TJ=25℃ at Rated DC Blocking Voltage @ T J=125℃ IR 10.0 500 μA I2t Rating for Fusing (t<8.3ms) I2t 508 A2s Typical Junction Capacitance Per Element (Note1) CJ 85 pF RθJC 0.6 ℃/W TJ -55 to +150 ℃ TSTG -55 to +150 ℃ Typical Thermal Resistance Operating Temperature Range Storage Temperature Range NOTES: 1.Measured at 1.0MHz and applied reverse voltage of 4.0V DC. 2.Device mounted on 300mm*300mm*1.6mm Cu plate heatsink. 2015.0ϴ www.willas.com.tw Rev.Ś0ϭ P1 RS2505M-U1 25A GLASS PASSIVATED ULTRA LOW VF BRIDGE RECTIFIERS - 600V FIG.2-MAXMUN NON-REPETITIVE SURGE CURRENT WITH HEATSINK PEAK FORWARD SURGE CURRENT , AMPERES AVERAGE FORWARD CURRENT AMPERES FIG.1-FORWARD CURRENT DERATING CURVE 25 20 SINGLE PHASE HALF WAVE 60Hz RESISTIVE OR INDUCTIVE LOAD 15 10 WITHOUT HEATSINK 5 0 0 20 40 60 100 80 120 140 CASE TEMPERATURE, °C 350 300 250 200 150 TJ=25°C SINGLE -SINE- WAVE (JEDEC METHOD) 100 50 0 1 2 10 20 50 5 NUMBER OF CYCLES AT 60Hz 100 FIG.4-TYPICAL FORWARD CHARACTERISTICS 200 FIG.3-TYPICAL JUNCTION CAPACITANCE INSTANTANEOUS FORWARD CURRENT, AMPERES 100 100 10 TJ=25°C,f=1MHZ 10 1.0 TJ = 25°C PULSE WIDTH 300us 0.1 1.0 1.0 10.0 0 100 0.2 0.4 0.6 0.8 1.0 1.2 1.4 INSTANTANEOUS FORWARD VOLTAGE. VOLTS REVERSE VOLTAGE,(VOLTS) FIG.5-TYPICAL REVERSE CHARACTERISTICS 1000 INSTANTANEOUS REVERSE CURRENT ,(uA) CAPACITANCE,(pF) 1000 TJ=125°C 100 TJ=100°C 10 TJ=50°C 1.0 TJ=25°C 0.1 0 20 40 60 80 100 PERCENT OF RATED PEAK REVERSE VOLTAGE,(%) 2015.0ϴ www.willas.com.tw Rev.Ś0ϭ P2 RS2505M-U1 25A GLASS PASSIVATED ULTRA LOW VF BRIDGE RECTIFIERS - 600V Outline Drawing RS-6M 1.193(30.3) 1.169(29.7) ~ ~ .165(4.20) .150(3.80) .708(18.00) .669(17.00) .094(2.40) .078(2.00) .114(2.90) .098(2.50) .031(0.80) .023(0.60) .303(7.70) .287(7.30) Dimensions in inches and (millimeters) 2015.0ϴ .134(3.40) .122(3.10) .441(11.20) .425(10.80) .106(2.7) .096(2.3) .043(1.10) .035(0.90) .402(10.2) .386(9.80) .800(20.30) .697(17.70) .197(5.00) .189(4.80) .173(4.40) .150(3.80) .134(3.40) www.willas.com.tw Rev.B Rev.Ś0ϭ P3 RS2505M-U1 25A GLASS PASSIVATED ULTRA LOW VF BRIDGE RECTIFIERS - 600V Ordering Information: Device PN RS2505M-hϭ (1)G(2)-WS Packing Tube Packing:15pcs/Tube; 600pcs/Box Note: 1. Packing code: Empty is Tube Packing 2. RoHS product for packing code suffix ”G”, Halogen free product for packing code suffix "H" . ***Disclaimer*** WILLAS reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. WILLAS or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on WILLAS data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. WILLAS does not assume any liability arising out of the application or use of any product or circuit. This is the preliminary specification. WILLAS products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of WILLAS. Customers using or selling WILLAS components for use in such applications do so at their own risk and shall agree to fully indemnify WILLAS Inc and its subsidiaries harmless against all claims, damages and expenditures. 2015.0ϴ www.willas.com.tw Rev.Ś0ϭ P4