GBU6J-U1(GBU(R))2015.07_h 01

GBU6J-U1
6A GLASS PASSIVATED ULTRA LOW VF BRIDGE RECTIFIERS - 600V
PRIMARY CHARACTERISTICS
VRRM
600V
I(AV)
6.0A
VF
0.89V
I2t
127A2s
TJ,Max
150℃
GBU(R)
PACKAGE
.
● Body Marking : GBU6J
UL Mark
Logo
Marking Code
VYM
6J
GBU
Date Code
.
Positive Electrodes
V:Product Line Code
Y:1-digit BC year code, 4-2014,5-2015…etc
..
M:Month Code, Ex : 1-1,2-2,---10-O,11-N,12-D
:ULTRA LOW VF
FEATURES
MECHANICAL DATA
Surge overload rating -175 amperes

Case:Molded plastic,GBU(R)
peak

Polarity:Shown above

Ideal for printed circuit board

Terminals :Plated terminals,

Reliable low cost construction utilizing
solderable per MIL-STD-750,Method
molded plastic technique
2026


Moisture Sensitivity Level 1

Epoxy : UL94-V0 rated flame
retardant
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25℃ ambient temperature unless otherwise specified.
Single phase, half wave ,60Hz, resistive or inductive load.
For capacitive load, derate current by 20%
CHARACTERISTICS
SYMBOL
GBU6J-U1
UNIT
Maximum Recurrent Peak Reverse Voltage
VRRM
600
V
Maximum RMS Voltage
VRMS
420
V
Maximum DC Blocking Voltage
VDC
600
V
Maximum Average Forward (with heatsink Note 2)
Rectified Current
@ T C=100℃ (without heatsink)
Peak Forward Surge Current
I(AV)
IFSM
8.3ms Single Half Sine-Wave
6.0
A
2.8
175
A
0.89
V
Super Imposed on Rated Load (JEDEC Method)
Maximum Forward Voltage at 3.0A DC
Maximum DC Reverse Current
@ TJ=25℃
at Rated DC Blocking Voltage
@ T J=125℃
VF
IR
10.0
μA
500
I2t Rating for Fusing (t<8.3ms)
I2t
127
A2s
Typical Junction Capacitance Per Element (Note1)
CJ
50
pF
RθJC
2.2
℃/W
TJ
-55 to +150
℃
TSTG
-55 to +150
℃
Typical Thermal Resistance
Operating Temperature Range
Storage Temperature Range
NOTES: 1.Measured at 1.0MHz and applied reverse voltage of 4.0V DC.
2.Device mounted on 75mm*75mm*1.6mm Cu plate heatsink.
2015.0ϳ
www.willas.com.tw
Rev.Ś0ϭ
P1
GBU6J-U1
6A GLASS PASSIVATED ULTRA LOW VF BRIDGE RECTIFIERS - 600V
FIG.2-MAXIMUM NON-REPETITIVE SURGE CURRENT
6.0
180
PEAK FORWARD SURGE CURRENT,
AMPERES
AVERAGE FORWARD CURRENT
AMPERES
FIG.1-FORWARD CURRENT DERATING CURVE
WITH HEATSINK
5.0
4.0
WITHOUT HEATSINK
3.0
2.0
SINGLE PHASE HALF WAVE 60Hz
RESISTIVE OR INDUCTIVE LOAD
1.0
0.0
0
20
40
60
100
80
120
140
160
PULSE WIDTH 8.3ms
SINGLE HALF-SINE-WAVE
(JEDEC METHOD)
120
80
40
0
1
10
5
2
CASE TEMPERATURE, °C
20
50
100
NUMBER OF CYCLETS AT 60Hz
FIG.4-TYPICAL FORWARD CHARACTERISTICS
FIG.3-TYPICAL JUNCTION CAPACITANCE
100
20.0
INSTANTANEOUS FORWARD CURRENT,
AMPERES
CAPACITANCE,(pF)
10.0
10
TJ=25°C,f=1MHZ
1.0
1.0
10.0
100
1.0
0.1
TJ=25°C
0.01
REVERSE VOLTAGE,VOLTS
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
INSTANTANEOUS FORWARD VOLTAGE. VOLTS
FIG.5-TYPICAL REVERSE CHARACTERISTICS
INSTANTANEOUS REVERSE CURRENT ,(uA)
1000
TJ=125°C
100
TJ=100°C
10
TJ=50°C
1.0
TJ=25°C
0.1
0
20
40
60
80
100
PERCENT OF RATED PEAK REVERSE VOLTAGE,(%)
2015.0ϳ
www.willas.com.tw
Rev.Ś0ϭ
P2
GBU6J-U1
6A GLASS PASSIVATED ULTRA LOW VF BRIDGE RECTIFIERS - 600V
Outline Drawing
GBU(R)
.437(11.1)
.430(10.9)
.126(3.2)*45°
CHAMFER
.874(22.2)
.860(21.8)
.161(4.1)
.134(3.4)
.752(19.1)
.720(18.3)
.232(5.9)
.213(5.4)
.401(10.2)
.392(9.80)
.073(1.85)
.057(1.45)
.100(2.54)
.085(2.16)
.720(18.29)
.680(17.27)
.047(1.2)
.035(0.9)
.080(2.03)
.065(1.65)
.210
.190
(5.3)
(4.8)
.210
.190
(5.3)
(4.8)
.210
.190
(5.3)
(4.8)
.106(2.7)
.091(2.3)
.022(.56)
.018(.46)
Dimensions in inches and (millimeters)
2015.0ϳ
.139(3.53)
.133(3.37)
www.willas.com.tw
Rev.B-1
Rev.Ś0ϭ
P3
GBU6J-U1
6A GLASS PASSIVATED ULTRA LOW VF BRIDGE RECTIFIERS - 600V
Ordering Information:
Device PN
GBU6J-U1 (1)G(2)-WS
Packing
Tube Packing:20pcs/Tube; 1000pcs/Box
Note: 1. Packing code: Empty is Tube Packing
2. RoHS product for packing code suffix ”G”, Halogen free product for packing code suffix "H" .
***Disclaimer***
WILLAS reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. WILLAS or anyone on its behalf assumes no responsibility or liability
for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters
which may be included on WILLAS data sheets and/ or specifications can
and do vary in different applications and actual performance may vary over time.
WILLAS does not assume any liability arising out of the application or
use of any product or circuit.
This is the preliminary specification. WILLAS products are not designed, intended or
authorized for use in medical, life-saving implant or other applications intended for
life-sustaining or other related applications where a failure or malfunction of component
or circuitry may directly or indirectly cause injury or threaten a life without expressed
written approval of WILLAS. Customers using or selling WILLAS components for use in
such applications do so at their own risk and shall agree to fully indemnify WILLAS Inc
and its subsidiaries harmless against all claims, damages and expenditures.
2015.0ϳ
www.willas.com.tw
Rev.Ś0ϭ
P4