Test Procedure for the NCP5106B Evaluation Board
6/6/2007
A
Vac
A
V
V
J2 jumper
Table 1: Required Equipment
AC power source can be able to
deliver 230Vrms or 110Vrms
1 resistive load: 200 Ω / 50 W
two volt-meters
two ampere-meters
One NCP5106B Evaluation Board
Test Procedure:
1. First of all check if you need or not the jumper #2 (J2 on the board close
the diode bridge). This jumper must be removed in case of European mains
(230 Vac input voltage) and have to placed in case of US mains (110 Vac).
This jumper is used to build a voltage doublers just after the bridge diode
in case of US mains input voltage range.
2. Connect the test setup as shown above:
• AC source
• Voltmeter and Ampere meter on the load
• Load on the output
3. Apply 230 Vac if European mains or 110 Vac for the US mains on the input
connector.
Rload
200Ω
4. Compare Iload and Vload with the following table according your input
mains voltage.
5. If you get the correct output and input voltage, you can now connect a 36
W fluorescent tube on the output (see the ballast connection figure).
Test results:
Input mains
J2
European
Removed
Yes Î max
input
voltage: 132
Vrms
US
Vin
(Vrms)
230 V
Iin (Arms)
278 mA
Vload
(Vrms)
303 V
Iload
(Arms)
370 mA
110 V
514 mA
263 V
340 mA
Input connection
A
Vac
36 W
Tube
V
Output connection
Figure 1: Ballast connection