AC Power For Business-Critical Continuity™ Emerson Network Power Rack PDU Systems Product Selection Guide - North American Models TABLE OF CONTENTS 1.0 EMERSON NETWORK POWER RACK PDU SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1.1 Safety and Agency Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2.0 DETERMINING THE RIGHT EMERSON PDU FOR YOUR APPLICATION . . . . . . . . . . . . . . . . . . .2 3.0 KNURR DI-STRIP PRODUCT SELECTION GUIDE - BASIC RACK PDUS . . . . . . . . . . . . . . . . .3 3.1 Overview - Basic Rack PDUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3.2 Basic Rack PDU Optional Cord Sets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3.3 Dimensional Drawings - Basic Rack PDUs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 4.0 LIEBERT MPH PRODUCT SELECTION GUIDE - MANAGED RACK PDUS . . . . . . . . . . . . . . . 27 4.1 Overview - Managed Rack PDUs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 4.2 Specifications - Liebert MPH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 4.3 Model Number Configuration - Liebert MPH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 4.4 Managed Rack PDU Optional Cord Sets and Cable Restraints . . . . . . . . . . . . . . . . . . . . . . 30 4.5 Dimensional Drawings - Managed Rack PDUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 5.0 LIEBERT MPX - ADAPTIVE RACK PDUS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 5.1 Overview - Adaptive Rack PDUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 5.2 MPX PRC (Power Rail Chassis). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 5.3 MPX PEM (Power Entry Module) and MPX IPC (Input Power Cord) . . . . . . . . . . . . . . . . . 36 5.4 MPX BRM (Branch Receptacle Module) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 5.5 Adaptive Rack PDU Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 5.5.1 5.5.2 5.5.3 5.5.4 5.5.5 5.5.6 5.5.7 Cord Sets and Cable Restraints. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Liebert RPC™ (RPC-1000) and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Part Numbers for Liebert RPC and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ports on the Liebert RPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Liebert RPC Capabilities and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RPC BDM—Basic Display Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Temperature/Humidity Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 37 38 38 39 40 40 6.0 LIEBERT MPX SYSTEM PRODUCT SELECTION GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 6.1 STEP 1 - Select an MPX PRC (Quantity x 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 6.2 STEP 2 - Select an MPX PEM / MPX IPC (Quantity x 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 6.3 STEP 3 - Select an MPX BRM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 6.4 STEP 4 - Select Communication Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 6.5 System Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 6.6 Specifications for Liebert MPX Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 6.7 Dimensional Drawings - Adaptive Rack PDUs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 i FIGURES Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 Figure 20 Figure 21 Figure 22 Figure 23 Figure 24 Figure 25 Figure 26 Figure 27 Figure 28 Figure 29 Figure 30 Figure 31 Knurr DI-STRIP 35351011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Knurr DI-STRIP 35351021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Knurr DI-STRIP 35351031 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Knurr DI-STRIP 35351041 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Knurr DI-STRIP 35351051 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Knurr DI-STRIP 35351061 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Knurr DI-STRIP 35351081 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Knurr DI-STRIP 35352011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Knurr DI-STRIP 35352021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Knurr DI-STRIP 35352031 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Knurr DI-STRIP 35352041 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Knurr DI-STRIP 35352051 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Knurr DI-STRIP 35352061 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Knurr DI-STRIP 35352078 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Knurr DI-STRIP 35353011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Knurr DI-STRIP 35353021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Knurr DI-STRIP 35353031 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Knurr DI-STRIP 35353041 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Knurr DI-STRIP 35353051 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Knurr DI-STRIP 35353061 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Knurr DI-STRIP 35353078 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Knurr DI-STRIP 35353088 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Liebert MPH rack mount power strip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Liebert MPH vertical power strip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Liebert MPX 1880 and 1035 models and components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 MPX PRC (Power Rail Chassis) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Liebert RPC ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 RPC BDM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Temperature/humidity sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Liebert MPX MPXPRC-1035mm mixed modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Liebert MPX MPXPRC-1880mm mixed modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 TABLES Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8 Table 9 Specifications - Knurr DI-STRIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Cord sets - Knurr DI-STRIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Specifications - Liebert MPH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Cord sets and cable restraints - Liebert MPH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Selections for Power Entry Module MPXPEM-NVAXXAXX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Selections for Power Entry Module MPXPEM-NHBXXV30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Selections for Power Entry Module MPXPEM-NHBXXX30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Selections for Power Entry Module MPXPEM-NHBXXW30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Specifications - MPX BRM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 ii Emerson Network Power Rack PDU Systems 1.0 EMERSON NETWORK POWER RACK PDU SYSTEMS Emerson Network Power’s Rack PDU Systems is a family of products that delivers power and management to connected IT equipment through a global and comprehensive offering including Basic, Managed and Adaptive Rack PDU systems. Each PDU type offers simplified installation and easy operation. Each type is compatible with standard rack enclosures. These Emerson Rack PDUs provide easy low-cost installation, simple relocation, security and proven design and performance. Emerson Rack PDUs can be set up with varying degrees of power-monitoring and management. When power or management requirements grow, the adaptive PDUs are scalable, enabling them to grow with the installation. Emerson PDUs are available for the entire spectrum of power needs of every type of rack equipment. • Knurr® DI-STRIP - Basic Rack PDU systems, provide a broad range of power distribution capacities and connectivity solutions in a robust package. • Liebert MPH™ - Managed Rack PDUs with single-phase or three-phase capability for fixed power input/output with remote management support; one-piece unit with monitoring at the branch level and control at the receptacle level; available in rack-mount and zero U configurations. • Liebert MPX™ - Adaptive Rack PDUs built with modular and scalable components that can be installed and reconfigured on-site to meet changing input and output power connectivity needs; with remote monitoring at the branch level and receptacle management and control at the receptacle level. 1.1 Safety and Agency Compliance Where a conflict arises between the following documents and statements made herein, the statements in this specification will govern. North American Units - 120V and 208V (Single-Phase and Three-Phase) • • • • • UL 60950-1 Information Technology Equipment CAN/CSA-C22.2 No. 60950-1-03 Information Technology Equipment FCC, Title 47, Part 15 Subpart B for Class A operation as defined by ANSI Standard C63.4 ISTA Procedure 1A and 2A RoHS Compliant 1 Determining the Right Emerson PDU for Your Application 2.0 DETERMINING THE RIGHT EMERSON PDU FOR YOUR APPLICATION Each of the Rack PDU systems Emerson offers is well-suited for delivering power to sensitive, highcapacity, rack-mounted equipment. Determining which is best for a particular installation requires knowing the basic power requirements of the equipment in the rack, deciding on the acceptable or preferable level of monitoring and control and then balancing those considerations against site requirements. The Emerson Rack PDU product line includes models to fit all types of installations: new or established; stable or rapidly changing; contracting or expanding. Each type of installation may require any or all types of Emerson Rack PDUs. After determining your requirements, refer to the data and specifications for each product. 2 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs 3.0 KNURR DI-STRIP PRODUCT SELECTION GUIDE - BASIC RACK PDUS 3.1 Overview - Basic Rack PDUs The Knurr DI-STRIP, a Basic Rack PDU system, provides a broad range of power distribution capacities and connectivity solutions in a robust package. The Knurr DI-STRIP includes an input power cord with appropriate input plug connection and hydraulic-magnetic branch rated overload protection as appropriate; basic rack mounting provisions are also provided. Knurr DI-STRIP Rack PDUs are available in rack mount and vertical zero-U form factors. The Knurr DI-STRIP fits most standard 600mm width network equipment rack enclosures. Product fit should be confirmed for each application. Table 1 Specifications - Knurr DI-STRIP INPUT OUTPUT Voltage Rated Amps Max Continuous Amps kW* Phase Plug Receptacle/Socket Configuration 035351011 120 15 12 1.4 1 NEMA 5-15P (9) NEMA 5-15R 035351021 035351031 035351041 035351051 035351061 035351081 035352011 120 120 120 120 120 120 208-240 15 15 20 20 20 30 20 12 12 16 16 16 24 16 1.4 1.4 1.9 1.9 1.9 2.8 3.3 1 1 1 1 1 1 1 NEMA 5-15P NEMA 5-15P NEMA L5-20P NEMA 5-20P NEMA L5-20P NEMA L5-30P NEMA L6-20P (12) NEMA 5-15R (18) NEMA 5-15R (9) NEMA 5-20 T-Slot (12) NEMA 5-20 T-Slot (12) NEMA 5-20 T-Slot (24) NEMA 5-20 T-Slot (9) IEC-C13 sockets 035352021** 208-240 20 16 3.3 1 IEC-C20 inlet (9) IEC-C13 sockets 035352031 035352041** 035352051 035352061 208-240 208-240 208-240 208-240 20 20 30 30 16 16 24 24 3.3 3.3 4.9 4.9 1 1 1 1 NEMA L6-20P IEC-C20 inlet NEMA L6-30P NEMA L6-30P 035352078 208-240 30 24 4.9 1 NEMA L6-30P 035353021 120/208 20 16 5.7 3 NEMA L21-20P 035353031 120/208 20 16 5.7 3 NEMA L21-20P 035353041 035353011 120/208 120/208 20 30 16 24 5.7 8.6 3 3 NEMA L21-20P NEMA L21-30P 035353051 120/208 30 24 8.6 3 NEMA L21-30P 035353061 120/208 30 24 8.6 3 NEMA L21-30P (12) IEC-C13 sockets (12) IEC-C13 sockets (4) IEC-C19 sockets (24) IEC-C13 sockets (20) IEC-C13 + (4) IEC-C19 sockets (18) IEC-C13 + (6) IEC-C19 sockets (27) IEC-C13 + (6) IEC-C19 sockets (27) 5-20 T-Slot (6) IEC-C19 sockets (18) IEC-C13 + (6) IEC-C19 sockets (27) IEC-C13 + (6) IEC-C19 sockets 035353078 208-240 60 48 17.3 3 035353088 208-240 42 34 24.4 3 Part Number IEC60309 (3 pole, 4 wire, 250VAC, blue) (2) IEC60309 (3 pole, 4 wire, 250VAC, blue) All input cords are 10 ft. (3m) in length. * Formulas used to calculate the kW: For single-phase: input voltage x max continuous amps = watts For three-phase: input voltage x max continuous amps x 1.73 = watts ** Knurr DI-STRIP output expansion modules require the use of a cord set for input power. 3 Form Factor Rack mount or Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Rack mount or Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical (42) IEC-C13 + (6) IEC-C19 sockets Vertical (42) IEC-C13 + (6) IEC-C19 sockets Vertical Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs 3.2 Basic Rack PDU Optional Cord Sets Output Cord Sets Output cord sets are available to support conversion of Rack PDU power output receptacles to alternative power output connections and to support Rack PDU output expansion capabilities. Conversion of power output connections can be provided on Rack PDUs with IEC-C19 receptacles. The output cord set for these systems includes an IEC-C20 plug to connect to the IEC-C19 receptacle, a 3 ft. (1m) power cord and receptacle to connect to user equipment. Available receptacles include: IEC-C13 to connect to IEC-C14 equipment plugs and IEC-C19 to connect to NEMA L6-20P equipment plugs. Knurr DI-STRIP output expansion modules are powered via an IEC-C20 input connection. These systems provide output expansion capabilities when connected to a receptacle on a separate Rack PDU. The output cord set for these systems includes an IEC-C19 receptacle to connect to the IEC-C20 plug on the output expansion Knurr DI-STRIP, a 3 ft. (1m) power cord and plug to connect to the Rack PDU receptacle providing power. Available plugs include: IEC-C20 to connect to an IEC-C19 Rack PDU receptacle. Input Cord Sets Input cord sets are available to support conversion of Rack PDU power input connections to alternative power input connections. Conversion of power input can be provided on Rack PDUs with L5-20P plug connections. The input cord set includes an L5-20R receptacle to connect to the L5-20P Rack PDU plug, a 1 ft. (0.3m) power cord and a 5-20P plug. Table 2 Cord sets - Knurr DI-STRIP Cord Sets Output Cord Sets - Power Output Conversion 539031G5 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 3 ft. (1m) 539031G6 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 10 ft. (3m) 539031G9 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 3 ft. (1m) 539031G10 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 10 ft. (3m) Output Cord Sets - Power Output Expansion 539031G7 Output Cord Set - Power Output Expansion - IEC-C20 to IEC-C19, 3 ft. (1m) 539031G8 Output Cord Set - Power Output Expansion - IEC-C20 to IEC-C19, 10 ft. (3m) 539031G3 Output Cord Set - Power Output Expansion - IEC-C14 to IEC-C19, 3 ft. (1m) 539031G4 Output Cord Set - Power Output Expansion - IEC-C14 to IEC-C19, 10 ft. (3m) Input Cord Sets - Power Input Conversion 539031G12 Input Cord Set - Power Input Conversion - L5-20R to 5-20P, 1 ft. (0.3m) 4 www.knuerr.com 5 5-15P 10 ft. (3m) 1 Phase 120 Voltage (VAC) 15 Rated Amps 12 Max. Cont. Amps 1 5-15R (9) 1 120 12 12 Max. Cont. Amps Receptacle Type Receptacle Bank Type (Qty) Phase Voltage (VAC) Per Receptacle Per Bank OUTPUT POWER Input Plug Input Cord INPUT POWER 5-15P (2-pole, 3-wire) SIDE VIEW REAR VIEW 12.2" (311mm) 17.6" (447mm) FRONT VIEW 2" (50mm) 1.7" (44mm) Rev. 3 NOTES: 1. Unit dimensions: 17.6" (447mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 2.5 lb. (1.1kg) 3. Shipping dimensions: 18.9" (480mm) L x 2.8" (71mm) W x 3.3" (84mm) D 4. Shipping weight: 2.8 lb. (1.3kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35351011 ENVIRONMENTAL: Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4°F to 140°F (-20°C to 60°C) AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) 2.5" (63mm) Figure 1 2.9" (73mm) 03.535.101.1 00/00 000000 3.3 120 VAC , 60Hz Input: max. 15A Outlets : max. 15A NA B AS IC DI S TR IP Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Dimensional Drawings - Basic Rack PDUs Knurr DI-STRIP 35351011 www.knuerr.com 6 5-15P 10 ft. (3m) 1 Phase 120 Voltage (VAC) 15 Rated Amps 12 Max. Cont. Amps 1 5-15R (9) 1 120 12 12 Max. Cont. Amps Receptacle Type Receptacle Bank Type (Qty) Phase Voltage (VAC) Per Receptacle Per Bank OUTPUT POWER Input Plug Input Cord INPUT POWER 5-15P (2-pole, 3-wire) SIDE VIEW REAR VIEW 12.2" (311mm) 19.6" (497mm) FRONT VIEW 2" (50mm) 1.7" (44mm) Rev. 3 NOTES: 1. Unit dimensions: 19.6" (497mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 2.7 lb. (1.2kg) 3. Shipping dimensions: 22.2" (565mm) L x 2.8" (70mm) W x 3.3" (85mm) D 4. Shipping weight: 3.1 lb. (1.4kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35351021 ENVIRONMENTAL: Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4°F to 140°F (-20°C to 60°C) AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) 2.5" (63mm) Figure 2 4.8" (123mm) 03.535.102.1 00/00 000000 120 VAC , 60Hz Input: max. 15A Outlets : max. 15A NA B AS IC DI S TR IP Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Knurr DI-STRIP 35351021 NA B AS IC DI S TR IP www.knuerr.com 7 5-15P 10 ft. (3m) 1 Phase 120 Voltage (VAC) 15 Rated Amps 12 Max. Cont. Amps SIDE VIEW REAR VIEW 1 5-15R (18) 1 120 12 12 Max. Cont. Amps Receptacle Type Receptacle Bank Type (Qty) Phase Voltage (VAC) Per Receptacle Per Bank OUTPUT POWER Input Plug Input Cord 5-15P (2-pole, 3-wire) 12.7" (323mm) 27.4" (697mm) FRONT VIEW 2" (50mm) 2.5" (63mm) Rev. 3 NOTES: 1. Unit dimensions: 27.4" (697mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 3.3 lb. (1.5kg) 3. Shipping dimensions: 42" (1065mm) L x 2.4" (60mm) W x 3" (75mm) D 4. Shipping weight: 3.8 lb. (1.72kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35351031 ENVIRONMENTAL: Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4°F to 140°F (-20°C to 60°C) AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) 12.2" (311mm) 1.7" (44mm) Figure 3 INPUT POWER 03.535.103.1 00/00 000000 120 V AC , 60Hz Input: max. 15A Outlets : max. 15A Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Knurr DI-STRIP 35351031 8 L5-20P 10 ft. (3m) 1 Phase 120 Voltage (VAC) L5-20P (2 pole, 3 wire) 20 Rated Amps 16 Max. Cont. Amps SIDE VIEW REAR VIEW 17.6" (447mm) FRONT VIEW 1 5-20R (9) 1 120 16 16 Max. Cont. Amps Receptacle Type Receptacle Bank Type (Qty) Phase Voltage (VAC) Per Receptacle Per Bank OUTPUT POWER Input Plug Input Cord INPUT POWER www.knuerr.com Rev. 3 NOTES: 1. Unit dimensions: 17.6" (447mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 3 lb. (1.35kg) 3. Shipping dimensions: 26.8" (680mm) L x 2.4" (60mm) W x 3.9" (100mm) D 4. Shipping weight: 3.4 lb. (1.54kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35351041 ENVIRONMENTAL: Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4°F to 140°F (-20°C to 60°C) AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) 2" (50mm) 1.7" (44mm) Figure 4 03.535.104.1 00/00 000000 120 VAC , 60Hz Input: max. 15A Outlets : max. 15A NA B AS IC DI S TR IP Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Knurr DI-STRIP 35351041 NA B AS IC DI S TR IP 9 5-20P 10 ft. (3m) 1 Phase 120 Voltage (VAC) 5-20P (2-pole, 3-wire) 20 Rated Amps 16 Max. Cont. Amps SIDE VIEW REAR VIEW 1 5-20R (9) 1 120 16 16 2.5" (63mm) 2" (50mm) 1.7" (44mm) Rev. 3 NOTES: 1. Unit dimensions: 19.6" (497mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 3.5 lb. (1.57kg) 3. Shipping dimensions: 26.8" (680mm) L x 2.4" (60mm) W x 3.9" (100mm) D 4. Shipping weight: 3.9 lb. (1.76kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35351051 ENVIRONMENTAL: Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4°F to 140°F (-20°C to 60°C) AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) 19.6" (497mm) FRONT VIEW 12.2" (311mm) Receptacle Type Max. Cont. Amps Receptacle Bank Type (Qty) Phase Voltage (VAC) Per Receptacle Per Bank OUTPUT POWER Input Plug Input Cord INPUT POWER 4.8" (123mm) www.knuerr.com Figure 5 03.535.105.1 00/00 000000 120 VAC , 60Hz Input: max. 15A Outlets : max. 15A Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Knurr DI-STRIP 35351051 www.knuerr.com 10 L5-20P 10 ft. (3m) 1 Phase 120 Voltage (VAC) 20 Rated Amps 16 Max. Cont. Amps 1 5-20R (12) 1 120 16 16 Max. Cont. Amps Receptacle Type Receptacle Bank Type (Qty) Phase Voltage (VAC) Per Receptacle Per Bank OUTPUT POWER Input Plug Input Cord INPUT POWER L5-20P (2-pole, 3-wire) SIDE VIEW REAR VIEW 2.5" (63mm) 2" (50mm) 1.7" (44mm) Rev. 3 NOTES: 1. Unit dimensions: 19.6" (497mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 3.2 lb. (1.47kg) 3. Shipping dimensions: 24.6" (625mm) L x 2.4" (60mm) W x 3.9" (100mm) D 4. Shipping weight: 3.5 lb. (1.6kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35351061 ENVIRONMENTAL: Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4°F to 140°F (-20°C to 60°C) AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) 12.2" (311mm) 19.6" (497mm) FRONT VIEW Figure 6 4.8" (123mm) 03.535.106.1 00/00 000000 120 VAC , 60Hz Input: max. 15A Outlets : max. 15A NA B AS IC DI S TR IP Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Knurr DI-STRIP 35351061 1.8" (46mm) NA B AS IC www.knuerr.com 11 L5-30P 10 ft. (3m) 1 Phase 120 Voltage (VAC) 30 Rated Amps 24 Max. Cont. Amps 5-20R (12) 5-20R (12) 1 2 1 1 120 120 16 16 20 20 24.5" (622mm) Branch 2 Rev. 4 NOTES: 1. Unit dimensions: 43.2" (447mm) L x 1.7" (44mm) W x 3.3" (85mm) D 2. Unit weight: 7.51 lb. (3.4kg) 3. Shipping dimensions: 44.9" (1140mm) L x 2.8" (70mm) W x 6.3" (160mm) D 4. Shipping weight: 8.4 lb. (3.8kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35351081 ENVIRONMENTAL: Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4°F to 140°F (-20°C to 60°C) AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) SIDE VIEW REAR VIEW 43.2" (1097mm) FRONT VIEW Max. Cont. Amps Receptacle Type Receptacle Branch Type (Qty) Phase Voltage (VAC) Per Receptacle Per Branch OUTPUT POWER Input Plug L5-30P (2-pole, 3-wire) 16.6" (422mm) Input Cord INPUT POWER 03.535.108.1 00/00 000000 120 VAC , 60Hz Input: max. 15A Outlets : max. 15A Branch 1 20A branch circuit breakers 3.3" (85mm) 2.1" (53mm) 1.7" (44mm) Figure 7 DI S TR IP 20A branch circuit breakers Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Knurr DI-STRIP 35351081 12 L6-20P 10 ft. (3m) 1 Phase 208-240 Voltage (VAC) L6-20P (2-pole, 3-wire) 20 Rated Amps 16 Max. Cont. Amps SIDE VIEW REAR VIEW FRONT VIEW 17.6" (447mm) 1 IEC-C13 (9) 1 208-240 12 16 Max. Cont. Amps Receptacle Type Receptacle Bank Type (Qty) Phase Voltage (VAC) Per Receptacle Per Bank OUTPUT POWER Input Plug Input Cord INPUT POWER www.knuerr.com Rev. 3 NOTES: 1. Unit dimensions: 17.6" (447mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 3.2 lb. (1.4kg) 3. Shipping dimensions: 24.6" (625mm) L x 2.4" (60mm) W x 3.9" (100mm) D 4. Shipping weight: 3.4 lb. (1.5kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35352011 ENVIRONMENTAL: Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4°F to 140°F (-20°C to 60°C) AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) 2" (50mm) 1.7" (44mm) Figure 8 03.535.201.1 00/00 000000 120 VAC , 60Hz Input: max. 15A Outlets : max. 15A NA B AS IC DI S TR IP Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Knurr DI-STRIP 35352011 NA B AS IC DI S TR IP 13 IEC-C20 Inlet * 10 ft. (3m) 1 Phase 208-240 Voltage (VAC) 20 Rated Amps 17.6" (447mm) 16 Max. Cont. Amps SIDE VIEW REAR VIEW 12.2" (311mm) FRONT VIEW 1 IEC-C13 (9) 1 208-240 12 16 Receptacle Type Max. Cont. Amps Receptacle Bank Type (Qty) Phase Voltage (VAC) Per Receptacle Per Bank OUTPUT POWER * Requires a cordset Input Input Cord INPUT POWER 2.5" (63mm) www.knuerr.com 2.9" (73mm) 2" (50mm) 1.7" (44mm) Rev. 3 NOTES: 1. Unit dimensions: 17.6" (447mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 1.5 lb. (0.7kg) 3. Shipping dimensions: 19" (483mm) L x 3" (75mm) W x 2.4" (60mm) D 4. Shipping weight: 1.7 lb. (0.8kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35352021 ENVIRONMENTAL: Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4°F to 140°F (-20°C to 60°C) AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) IEC-C20 inlet Figure 9 03.535.202.1 00/00 000000 120 V AC , 60Hz Input: max. 15A Outlets : max. 15A Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Knurr DI-STRIP 35352021 www.knuerr.com 14 L6-20P 10 ft. (3m) 1 Phase 208-240 Voltage (VAC) 20 Rated Amps 16 Max. Cont. Amps SIDE VIEW REAR VIEW 1 IEC-C13 (12) 1 208-240 12 16 2.5" (63mm) 2" (50mm) 1.7" (44mm) Rev. 3 NOTES: 1. Unit dimensions: 19.6" (497mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 3.4 lb. (1.5kg) 3. Shipping dimensions: 26.8" (680mm) L x 2.4" (60mm) W x 3.9" (100mm) D 4. Shipping weight: 3.7 lb. (1.68kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35352031 ENVIRONMENTAL: Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4°F to 140°F (-20°C to 60°C) AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) 12.2" (311mm) FRONT VIEW 19.6" (497mm) Max. Cont. Amps Receptacle Type Receptacle Bank Type (Qty) Phase Voltage (VAC) Per Receptacle Per Bank OUTPUT POWER Input Plug Input Cord INPUT POWER L6-20P (2-pole, 3-wire) 4.8" (123mm) 03.535.203.1 00/00 000000 120 VAC , 60Hz Input: max. 15A Outlets : max. 15A NA B AS IC DI S TR IP Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 10 Knurr DI-STRIP 35352031 www.knuerr.com 15 IEC-C20 inlet * 10 ft. (3m) 1 Phase 208-240 Voltage (VAC) 20 Rated Amps 16 Max. Cont. Amps SIDE VIEW REAR VIEW 1 IEC-C13 (12) 1 208-240 12 16 2.5" (63mm) 2" (50mm) 1.7" (44mm) Rev. 3 NOTES: 1. Unit dimensions: 19.6" (497mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 1.8 lb. (0.8kg) 3. Shipping dimensions: 22.6" (575mm) L x 2.4" (60mm) W x 3" (75mm) D 4. Shipping weight: 2.1 lb. (0.9kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35352041 ENVIRONMENTAL: Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4°F to 140°F (-20°C to 60°C) AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) 12.2" (311mm) Max. Cont. Amps Receptacle Type Receptacle Bank Type (Qty) Phase Voltage (VAC) Per Receptacle Per Bank OUTPUT POWER * Requires a cordset Input Plug Input Cord INPUT POWER 03.535.204.1 00/00 000000 120 VAC , 60Hz Input: max. 15A Outlets : max. 15A NA B AS IC DI S TR IP 4.8" (123mm) IEC-C20 INLET 19.6" (497mm) Figure 11 FRONT VIEW Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Knurr DI-STRIP 35352041 16 L6-30P 10 ft. (3m) 1 2 Branch 1 IEC-C19 (2) IEC-C19 (2) 30 Rated Amps Per Receptacle Type 208-240 Voltage L6-30P (2-pole, 3-wire) Max. Continuous Amps 24 Max. Cont. Amps 1 1 208-240 208-240 20 20 16 16 Branch 2 03.535.205.1 00/00 000000 120 VAC , 60Hz Input: max. 15A Outlets : max. 15A NA B AS IC DI S TR IP 20A branch circuit breaker www.knuerr.com 3.3" (85mm) 1.7" (44mm) 35352051 Rev. 3 AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH non-condensing, non-corrosive Storage Temperature: -4°F to 140°F (-20°C to 60°C) NOTES: 1. Unit Dimensions: 17.6" (447mm) L x 1.7" (44mm) W x 2.0" (50mm) D 2. Unit Weight: 4.8lb. (2.2kg) 3. Shipping Dimensions: 29.0" (740mm) L x 6.3" (160mm) W x 2.7" (70mm) D 4. Shipping Weight: 5.5lbs (2.5kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. SIDE VIEW REAR VIEW FRONT VIEW 17.6" (447mm) Branch 1 Phase Voltage (VAC) Per Receptacle Per Branch Phase Receptacle Type (Quantity) OUTPUT POWER Input Plug Input Cord INPUT POWER 1.8" (46mm) 20A branch circuit breaker Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 12 Knurr DI-STRIP 35352051 1.8" (46mm) www.knuerr.com 17 L6-30P 1 1 IEC-C13 (12) 1 2 Phase IEC-C13 (12) Branch 208-240 208-240 Voltage (VAC) 43.2" (1097mm) Max Cont. Amps 30 24 Rated Amps Max Cont. Amps SIDE VIEW REAR VIEW FRONT VIEW 20 20 12 12 Per Receptacle Per Branch 208-240 Per Receptacle Type Voltage (VAC) 1 BRANCH 1 Phase Receptacle Type (Quantity) OUTPUT POWER Input Plug 10 ft/3.0m L6-30P (2 Pole, 3 Wire) 16.6" (422mm) Input Cord INPUT POWER 03.535.206.1 00/00 000000 120 VAC , 60Hz Input: max. 15A Outlets : max. 15A NA B AS IC DI S TR IP 20A Branch Circuit Breaker BRANCH 2 Rev. 3 NOTES: 1. Unit Dimensions: 43.2" (1097mm) L x 1.7" (44mm) W x 3.3" (85mm) D 2. Unit Weight: 6.8lbs (3.1kg) 3. Shipping Dimensions: 44.9" (1140mm) L x 2.8" (70mm) W x 6.3" (160mm) D 4. Shipping Weight: 7.7lbs (3.5kg) 5. All wiring is to be in compliance with national and local electric codes. 035352061 6. Mounting provisions provided. AGENCY: CSA Tested to UL 60950-1 RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32° F-131° F (0° C-55° C ) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4° F-140° F (-20° C - 60° C ) 24.5" (622mm) 20A Branch Circuit Breaker 3.3" (85mm) 2.1 (53mm) 1.7" (44mm) Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 13 Knurr DI-STRIP 35352061 18 1 L6-30P 10 ft. (3m) IEC-C13 (10) / IEC-C19 (2) IEC-C13 (10) / IEC-C19 (2) 1 2 Branch Receptacle Type (Qty) OUTPUT POWER Phase Input Plug Input Cord INPUT POWER L6-30P (2-pole, 3-wire) 20A branch circuit breaker 30 1/1 1/1 208-240 / 208-240 208-240 / 208-240 Receptacle Type Phase Voltage (VAC) 208-240 12 / 16 12 / 16 20 20 Max. Cont. Amps Per Receptacle Per Branch 24 1.9" (47mm) Rev. 3 NOTES: 1. Unit dimensions: 21.3" (540mm) L x 6.7" (170mm) W x 1.9" (47mm) D 2. Unit weight: 15 lb. (6.8kg) 3. Shipping dimensions: 22.4" (570mm) L x 11.6" (295mm) W x 6.3" (160mm) D 4. Shipping weight: 18.3 lb. (8.3kg) 5. All wiring is to be in compliance with national and local electric codes. 35352078 6. Mounting provisions provided. ENVIRONMENTAL: Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4°F to 140°F (-20°C to 60°C) AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) 20A branch circuit breaker Voltage (VAC) Rated Amps Max. Cont. Amps BOTTOM VIEW TOP VIEW FRONT VIEW 21.3" (540mm) 6.7" (170mm) Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 14 Knurr DI-STRIP 35352078 1.8" [46mm www.knuerr.com 19 L21-30P (4 pole, 5 wire) Branch 1 27.4" (697mm) SIDE VIEW REAR VIEW 24.5" (622mm) FRONT VIEW L21-30P 3 120/208 30 24 IEC-C19 (2) IEC-C19 (2) IEC-C19 (2) 1 1 1 1 1 1 208-240 208-240 208-240 16 16 16 20 20 20 Max Cont. Amps Per Receptacle Type Receptacle Type Branch (Quantity) Phase Voltage (VAC) Per Receptacle Per Branch OUTPUT POWER 10 ft. (3m) 0.9" (23mm) Branch 3 20A Branch Circuit Breaker 3.3" (85mm) 1.7" (44mm) Rev. 3 NOTES: 1. Unit dimensions: 27.4" (697mm) L x 1.7" (44mm) W x 3.3" (85mm) D 2. Unit weight: 8 lb. (3.6kg) 3. Shipping dimensions: 64.6" (1640mm) L x 2.8" (70mm) W x 6.3" (160mm) D 4. Shipping weight: 9.4 lb. (4.3kg) 5. All wiring is to be in compliance with national and local electric codes. 035353011 6. Mounting provisions provided. ENVIRONMENTAL: Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH non-condensing, non-corrosive, Storage Temperature: -4°F to 140°F (-20°C to 60°C) AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) Branch 2 20A Branch Circuit Breaker Input Cord Input Plug Phase Voltage (VAC) Rated Amps Max Cont. Amps INPUT POWER 03.535.301.1 00/00 000000 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A NA BASIC DI STRIP 20A Branch Circuit Breaker Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 15 Knurr DI-STRIP 35353011 www.knuerr.com 20 L21-20P (4 pole, 5 wire) 12.7" (322mm) L21-20P 20 12 / 16 12 / 16 12 / 16 IEC-C13 (6)/IEC-C19 (2) 1 / 1 208-240/208-240 IEC-C13 (6)/IEC-C19 (2) 1 / 1 208-240/208-240 3 16 16 16 Branch 3 2.0" (50mm) 2.1" (53mm) 1.7" (44mm) 035353021 Rev. 3 NOTES: 1. Unit Dimensions: 39.3" (997mm) L x 1.7" (44mm) W x 2.0" (50mm) D 2. Unit Weight: 5.8 lb. (2.63kg) 3. Shipping Dimensions: 40.4" (1027mm) L x 2.3" (60mm) W x 3.9" (100mm) D 4. Shipping Weight: 6.2 lb. (2.8kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. AGENCY: CSA Tested to UL 60950-1 RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32°F-131°F (0°C to 55°C ) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4°F to 140°F (-20°C to 60°C ) 24.5" (622mm) Per Receptacle Per Branch IEC-C13 (6)/IEC-C19 (2) 1 / 1 208-240/208-240 Voltage (VAC) Max Cont. Amps 16 Max Cont. Amps SIDE VIEW REAR VIEW Branch 2 2 Phase Per Receptacle Type 120/208 39.3" (997mm) FRONT VIEW 1 Branch 3 Receptacle Type (Quantity) OUTPUT POWER 10 ft/3.0m Input Cord Input Plug Phase Voltage (VAC) Rated Amps INPUT POWER 03.535.302.1 00/00 000000 120 VAC , 60Hz Input: max. 15A Outlets : max. 15A NA BASIC DI ST RIP Branch 1 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 16 Knurr DI-STRIP 35353021 www.knuerr.com 11.9" (301mm) 21 L21-20P (4 Pole, 5 Wire) L21-20P 20 12 / 16 12 / 16 12 / 16 IEC-C13 (9) / IEC-C19 (2) 1 / 1 208-240/208-240 IEC-C13 (9) / IEC-C19 (2) 1 / 1 208-240/208-240 3 16 16 16 Per Receptacle Per Bank 2.0" (50mm) 2.5 (63mm) 1.7" (44mm) 035353031 Rev. 3 NOTES: 1. Unit Dimensions: 51.1" (1297mm) L x 1.7" (44mm) W x 2.0" (50mm) D 2. Unit Weight: 7.0 lb. (3.2kg) 3. Shipping Dimensions: 72.0" (1830mm) L x 2.4" (60mm) W x 3.5" (90mm) D 4. Shipping Weight: 7.5 lb. (3.4kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. AGENCY: CSA Tested to UL 60950-1 RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32°F to 131°F (0°C to 55°C ) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4°F to 140°F (-20°C to 60°C ) SIDE VIEW Max Cont. Amps 16 36.8" (934mm) REAR VIEW Max Cont. Amps IEC-C13 (9) / IEC-C19 (2) 1 / 1 208-240/208-240 Phase Voltage (VAC) Per Receptacle Type 120/208 2 Receptacle Type (Quantity) 3 Branch 2 FRONT VIEW 51.1" (1297mm) Branch 1 1 Bank OUTPUT POWER 10 ft/3.0m Input Cord Input Plug Phase Voltage (VAC) Rated Amps INPUT POWER 03.535.303.1 00/00 000000 120 V AC , 60Hz Input: max. 15A Outlets : max. 15A NA BASIC DI STRIP Branch 3 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 17 Knurr DI-STRIP 35353031 NA BASIC DI ST RIP www.knuerr.com 12.3" (312mm) 22 L21-20P (4 Pole, 5 Wire) L21-20P 120/208 20 1 1 1 5/20R (9) 5/20R (9) 5/20R (9) 2 3 Max Cont. Amps 16 Max Cont. Amps 16 16 120 16 120 120 16 16 16 24.5" (622mm) 39.3" [997mm 2.5 (63mm) 2.0" (50mm) 1.7" (44mm) 035353041 Rev. 3 NOTES: 1. Unit Dimensions: 39.3" (997mm) L x 1.7" (44mm) W x 2.0" (50mm) D 2. Unit Weight: 5.7lb. (2.6kg) 3. Shipping Dimensions: 40.4" (1027mm) L x 2.3" (60mm) W x 4.0" (100mm) D 4. Shipping Weight: 6.3lb. (2.85kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. AGENCY: CSA Tested to UL 60950-1 RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32°F to 131°F (0°C to 55°C ) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4°F to 140°F (-20°C to 60°C ) SIDE VIEW REAR VIEW 24.5" [622mm] Branch 2 FRONT VIEW 39.3" [997mm] Phase Voltage (VAC) Per Receptacle Per Bank 1 Per Receptacle Type Receptacle Type (Quantity) 3 Bank OUTPUT POWER 10 ft/3.0m Input Cord Input Plug Phase Voltage (VAC) Rated Amps INPUT POWER 03.535.304.1 00/00 000000 120 VAC , 60Hz Input: max. 15A Outlets : max. 15A Branch 1 Branch 3 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 18 Knurr DI-STRIP 35353041 www.knuerr.com 23 L21-30P 3 Phase SIDE VIEW REAR VIEW FRONT VIEW 51.1" (1297mm) 120 / 208 30 1/1 1/1 1/1 IEC-C13 (6) / IEC-C19 (2) IEC-C13 (6) / IEC-C19 (2) IEC-C13 (6) / IEC-C19 (2) 1 2 3 208-240/208-240 208-240/208-240 208-240/208-240 Branch 2 20A branch circuit breaker 12 / 16 12 / 16 12 / 16 20 20 20 Max. Cont. Amps Per Receptacle Per Branch 24 Voltage (VAC) Rated Amps Max. Cont. Amps L21-30P (4-pole, 5-wire) 25.7" (652mm) Receptacle Type Branch Receptacle Type (Qty) Phase Voltage (VAC) OUTPUT POWER 10 ft. (3m) Input Cord Input Plug INPUT POWER 1.8" (46mm) 03.535.305.1 00/00 000000 120 V AC , 60Hz Input: max. 15A Outlets : max. 15A NA B AS IC DI S TR IP Branch 1 20A branch circuit breaker 0.9" (23mm) 1.7" (44mm) 3.3" (85mm) Rev. 3 NOTES: 1. Unit dimensions: 51.1" (1297mm) L x 1.7" (44mm) W x 3.3" (85mm) D 2. Unit weight: 10.1 lb. (4.6kg) 3. Shipping dimensions: 64.6" (1640mm) L x 2.8" (70mm) W x 6.3" (160mm) D 4. Shipping weight: 11.6 lb. (5.25kg) 5. All wiring is to be in compliance with national and local electric codes. 35353051 6. Mounting provisions provided. ENVIRONMENTAL: Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4°F to 140°F (-20°C to 60°C) AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) 24.5" (622mm) Branch 3 20A branch circuit breaker Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 19 Knurr DI-STRIP 35353051 24 L21-30P 10ft/3.0m 30 IEC-C13 (9) / IEC-C19 (2) 1 / 1 208-240/208-240 IEC-C13 (9) / IEC-C19 (2) 1 / 1 208-240/208-240 IEC-C13 (9) / IEC-C19 (2) 1 / 1 208-240/208-240 3 Voltage (VAC) 2 Phase 12 / 16 12 / 16 12 / 16 20 20 20 Per Receptacle Per Branch Max Cont. Amps 24 Max Cont. Amps Branch 3 20A Branch Circuit Breaker 0.9" (22mm) 1.7" (44mm) 035353061 Rev. 3 NOTES: 1. Unit Dimensions: 62.9" (997mm) L x 1.7" (44mm) W x 3.3" (85mm) D 2. Unit Weight: 11.0lb. (5.0kg) 3. Shipping Dimensions: 72.4" (1840mm) L x 2.8" (70mm) W x 6.3" (160mm) D 4. Shipping Weight: 12.7lb. (5.75kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. AGENCY: CSA Tested to UL 60950-1 3.3" RoHS Compliant (Reduction of Hazardous Substances) (85mm) ENVIRONMENTAL: Operating: 32°F to 131°F (0°C to 55°C ) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4°F to 140°F (-20°C to 60°C ) Rear View 49.0" (1245mm) Front View 62.9" (1597mm) Branch 2 20A Branch Circuit Breaker L21-30P (4 Pole, 5 Wire) Rated Amps Per Receptacle Type 120/208 Voltage (VAC) 1 Branch 3 Phase Receptacle Type (Quantity) OUTPUT POWER Input Plug Input Cord 13.0" (330mm) www.knuerr.com INPUT POWER 1.8" (46mm) 03.535.306.1 00/00 000000 120 VAC , 60Hz Input: max. 15A Outlets : max. 15A NA BASIC DI STRIP Branch 1 20A Branch Circuit Breaker Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 20 Knurr DI-STRIP 35353061 25 IEC 60309 IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) 2 3 4 5 6 3 Phase 1 Branch 20A Branch Circuit Breaker 60 1/1 1/1 1/1 1/1 1/1 1/1 Phase 12 / 16 12 / 16 12 / 16 12 / 16 12 / 16 12 / 16 208-240/208-240 208-240/208-240 208-240/208-240 208-240/208-240 208-240/208-240 20 20 20 20 20 20 Per Receptacle Per Branch Max. Cont. Amps 48 208-240/208-240 Voltage (VAC) Per Receptacle Type 208-240 Voltage (VAC) Rated Amps Max. Cont. Amps SIDE VIEW 20A Branch Circuit Breaker 20A Branch Circuit Breaker 1.9" (47mm) Rev. 5 NOTES: 1. Unit dimensions: 63.0" (1600mm) L x 6.7" (170mm) W x 1.9" (47mm) D 2. Unit Weight: 32.8lbs (14.9kg) 3. Shipping Dimensions: 74.0" (1880mm) L x 16.3" (415mm) W x 6.3" (160mm) D 4. Shipping Weight: 38.4lb. (17.4kg) 5. All wiring is to be in compliance with national and local electric codes. 035353078 6. Mounting provisions provided. AGENCY: UL 60950-1, cUL RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32°F-131°F (0°C to 55°C) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4°F to 140°F (-20°C to 60°C) 20A Branch Circuit Breaker REAR VIEW FRONT VIEW IEC 60309 (3 POLE, 4 WIRE, 250VAC, BLUE) Receptacle Type (Quantity) OUTPUT POWER 10ft/3.0m INPUT POWER Input Cord Input Plug 20A Branch 20A Branch Circuit Breaker Circuit Breaker 63.0" (1600mm) 6.7" (170mm) Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 21 Knurr DI-STRIP 35353078 26 50 12 / 16 12 / 16 12 / 16 12 / 16 12 / 16 12 / 16 IEC-C13 (7) / IEC-C19 (1) 1 / 1 208-240/208-240 IEC-C13 (7) / IEC-C19 (1) 1 / 1 208-240/208-240 IEC-C13 (7) / IEC-C19 (1) 1 / 1 208-240/208-240 IEC-C13 (7) / IEC-C19 (1) 1 / 1 208-240/208-240 1/3 2/4 2/5 2/6 20 20 20 20 20 20 Per Receptacle Per Branch IEC-C13 (7) / IEC-C19 (1) 1 / 1 208-240/208-240 Voltage (VAC) 40 Max. Cont. Amps IEC-C13 (7) / IEC-C19 (1) 1 / 1 208-240/208-240 Phase Per Receptacle Type 208-240 Voltage (VAC) Rated Amps Max. Cont. Amps 1/2 Receptacle Type (Quantity) 3 Phase 1/1 Input/ Branch OUTPUT POWER Input Plug IEC 60309 Input Cord 10ft/3.0m INPUT POWER SIDE VIEW 20A Branch 20A Branch Circuit Breaker Circuit Breaker 1.9" (47mm) 035353088 Rev. 5 NOTES: 1. Unit dimensions: 63.0" (1600mm) L x 6.7" (170mm) W x 1.9" (47mm) D 2. Unit Weight: 44.5lb. (20.2kg) 3. Shipping Dimensions: 74.0" (1880mm) L x 16.3" (415mm) W x 6.3" (160mm) D 4. Shipping Weight: 50lb. (22.7kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. AGENCY: UL 60950-1, cUL RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32°F-131°F (0°C to 55°C) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4°F to 140°F (-20°C to 60°C) 20A Branch Circuit Breaker REAR VIEW IEC 60309 (3 POLE, 4 WIRE, 250VAC, BLUE) 20A Branch 20A Branch 20A Branch Circuit Breaker Circuit Breaker Circuit Breaker 63" (1600mm) FRONT VIEW 6.7" (170mm) Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 22 Knurr DI-STRIP 35353088 Liebert MPH Product Selection Guide - Managed Rack PDUs 4.0 LIEBERT MPH PRODUCT SELECTION GUIDE - MANAGED RACK PDUS 4.1 Overview - Managed Rack PDUs The Liebert MPH Managed Rack PDU system delivers power distribution, branch monitoring and receptacle control for IT devices. Liebert MPH Rack PDUs, with remote monitoring and/or control capabilities for power distribution at the load/equipment level, are designed to support the growth in rack electrical needs while meeting the new demands for remote power management. The Liebert MPH monitors electrical attributes of an individual Rack PDU, including real-time remote and (optional) local display of monitoring of aggregate and branch electrical parameters (status, thresholds, alarms) including voltage, amps, kW, and kW-hr. Liebert MPH features include branch load monitoring and control for continuous uptime and minimum disruptions; expandable monitoring interface providing simplified growth management; rugged construction; and the convenience of being factory-installed in the Knurr rack enclosure system. The Liebert MPH includes an input power cord with appropriate input plug connection and hydraulic-magnetic branch rated overload protection as appropriate; basic rack mounting provisions are also provided. Liebert MPH Managed Rack PDUs are available in rack mount and vertical zero-U form factors and are painted black. Liebert MPH – Managed Rack PDUs / Liebert MPH-NB Systems (Branch Monitoring Only) Liebert MPH-NB series Rack PDUs provide local and remote monitoring of individual PDU volts, amps, watts, and kilowatt-hours. Liebert MPH – Managed Rack PDUs / Liebert MPH-NC (Monitoring & Receptacle Control) Liebert MPH-NC series power strips provide the same features and functionality as the Liebert MPH-NB series with the additional capability of remote on/off control of individual receptacles. Local receptacle power on-off status is provided through an LED display. Liebert MPH – Managed Rack PDUs – ALL Liebert MPH Systems All Liebert MPH systems are provided with a factory-integrated Liebert RPC (Rack PDU Card RPC-1000) that provides Web-based remote monitoring via a direct IP network connection, Rack PDU Array™ interface connection to three additional Liebert MPH or Liebert MPX systems to allow viewing of up to four Rack PDUs on a single IP connection, an environmental sensor port, and a port for connection to the optional local display. Local display monitoring is provided via the optional RPC BDM (Basic Display Module) and integrated audible alarm. See 5.5 - Adaptive Rack PDU Optional Accessories for further details. Each Liebert MPH unit is provided with basic rack mounting provisions to meet a range of installation needs. The Liebert MPH fits most standard 600mm width network equipment rack enclosures. Product fit should be confirmed for each application. 27 Liebert MPH Product Selection Guide - Managed Rack PDUs 4.2 Specifications - Liebert MPH Table 3 Specifications - Liebert MPH INPUT Part Number Branch Monitoring MPH-NBR09AXXC30 MPH-NBV27AXXC30 MPH-NBR09AXXD30 MPH-NBV27AXXD30 MPH-NBR09NXXE30 MPH-NBV27NXXE30 MPH-NBR09NXXF30 MPH-NBV27NXXF30 OUTPUT Max. Voltage Rated Continuous Amps kW* Phase (VAC) Amps Plug Receptacle/Socket Configuration Form Factor (9) NEMA 5-20R T-Slot (27) NEMA 5-20R T-Slot (9) NEMA 5-20R T-Slot (27) NEMA 5-20R T-Slot (9) IEC-C13 (27) IEC-C13 (9) IEC-C13 (27) IEC-C13 (21) IEC-C13 & (6) IEC-C19 (27) IEC-C13 (21) IEC-C13 & (6) IEC-C19 (15) IEC-C13, (6) NEMA 5-20 T-slot & (6) IEC-C19 (27) NEMA 5-20R T-Slot Rack mount Vertical Rack mount Vertical Rack mount Vertical Rack mount Vertical 120 120 120 120 208-240 208-240 208-240 208-240 20 20 30 30 20 20 30 30 16 16 24 24 16 16 24 24 1.9 1.9 2.8 2.8 3.3 3.3 4.9 4.9 1 1 1 1 1 1 1 1 NEMA L5-20P NEMA L5-20P NEMA L5-30P NEMA L5-30P NEMA L6-20P NEMA L6-20P NEMA L6-30P NEMA L6-30P MPH-NBV27NOXF30 208-240 30 24 4.9 1 NEMA L6-30P MPH-NBV27NXXJ30 208-240 30 24 8.6 3 NEMA L15-30P MPH-NBV27NOXJ30 208-240 30 24 8.6 3 NEMA L15-30P MPH-NBV27AMXH30 120/208 30 24 8.6 3 NEMA L21-30P MPH-NBV27AXXH30 120/208 30 24 8.6 3 NEMA L21-30P MPH-NBV27ANXH30 120/208 30 24 8.6 3 NEMA L21-30P MPH-NBV27NXXH30 120/208 30 24 8.6 3 NEMA L21-30P MPH-NBV27NOXH30 120/208 30 24 8.6 3 NEMA L21-30P Receptacle Control MPH-NCR09AXXC30 MPH-NCV27AXXC30 MPH-NCR09AXXD30 MPH-NCV27AXXD30 MPH-NCR09NXXE30 MPH-NCV27NXXE30 MPH-NCR09NXXF30 MPH-NCV27NXXF30 120 120 120 120 208-240 208-240 208-240 208-240 20 20 30 30 20 20 30 30 16 16 24 24 16 16 24 24 1.9 1.9 2.8 2.8 3.3 3.3 4.9 4.9 1 1 1 1 1 1 1 1 MPH-NCV27NOXF30 208-240 30 24 4.9 1 MPH-NCV27NXXJ30 208-240 30 24 8.6 3 MPH-NCV27NOXJ30 208-240 30 24 8.6 3 MPH-NCV27AMXH30 120/208 30 24 8.6 3 MPH-NCV27AXXH30 120/208 30 24 8.6 3 NEMA L5-20P (9) NEMA 5-20R T-Slot NEMA L5-20P (27) NEMA 5-20R T-Slot NEMA L5-30P (9) NEMA 5-20R T-Slot NEMA L5-30P (27) NEMA 5-20R T-Slot NEMA L6-20P (9) IEC-C13 NEMA L6-20P (27) IEC-C13 NEMA L6-30P (9) IEC-C13 NEMA L6-30P (27) IEC-C13 (21) IEC-C13 & NEMA L6-30P (6) IEC-C19 NEMA L15-30P (27) IEC-C13 (21) IEC-C13 & NEMA L15-30P (6) IEC-C19 (15) IEC-C13, NEMA L21-30P (6) NEMA 5-20 T-slot & (6) IEC-C19 NEMA L21-30P (27) NEMA 5-20R T-Slot MPH-NCV27ANXH30 120/208 30 24 8.6 3 NEMA L21-30P MPH-NCV27NXXH30 120/208 30 24 8.6 3 NEMA L21-30P MPH-NCV27NOXH30 120/208 30 24 8.6 3 NEMA L21-30P All input cords are 10 ft. (3m) in length. * Formulas used to calculate the kW: For single-phase: input voltage x max continuous amps = watts For three-phase: input voltage x max continuous amps x 1.73 = watts 28 (21) IEC-C13 & (6) NEMA 5-20R T-Slot (27) IEC-C13 (21) IEC-C13 & (6) IEC-C19 (21) IEC-C13 & (6) NEMA 5-20R T-Slot (27) IEC-C13 (21) IEC-C13 & (6) IEC-C19 Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Rack mount Vertical Rack mount Vertical Rack mount Vertical Rack mount Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Liebert MPH Product Selection Guide - Managed Rack PDUs 4.3 Model Number Configuration - Liebert MPH Example: MPH N B R 09 AX XC 30 • Prefix: • Region: • Type: MPH N = North American B = Branch Monitoring C = Controlled Receptacles • Mounting: V = Vertical R = Rack mount • Output Power: • Quantity Receptacles (Total): 09 or 27 • Receptacle Type(s)—2 characters (each set): A = 5-20R T-Slot N = IEC-C13 O = IEC-C19 Note: Second character indicates a second receptacle type (X if no additional type chosen) • Input Power: • Plug Type: • First character = X • Second character: C = L5-20P D = L5-30P E = L6-20P F = L6-30P H = L21-30P J = L15-30P • Cord Length: 30 = 3.0m (10 ft.) 29 Liebert MPH Product Selection Guide - Managed Rack PDUs 4.4 Managed Rack PDU Optional Cord Sets and Cable Restraints Output Cord Sets Output cord sets are available to support conversion of Rack PDU power output receptacles to alternative power output connections and to support Rack PDU output expansion capabilities. Conversion of power output connections can be provided on Rack PDUs with IEC-C19 receptacles. The output cord set for these systems includes an IEC-C20 plug to connect to the IEC-C19 receptacle, a 3 ft. (1m) power cord and receptacle to connect to user equipment. Available receptacles include: IEC-C13 to connect to IEC-C14 equipment plugs and IEC-C19 to connect to NEMA L6-20P equipment plugs. Input Cord Sets Input cord sets are available to support conversion of Rack PDU power input connections to alternative power input connections. Conversion of power input can be provided on Rack PDUs with L5-20P plug connections. The input cord set includes an L5-20R receptacle to connect to the L5-20P Rack PDU plug, a 1 ft. (0.3m) power cord and a 5-20P plug. Cable Restraints (Liebert MPH - Vertical Systems) Cable restraints are available to secure user equipment power cord connections to IEC-C13 receptacles. The Liebert MPH supports all vertical-mount models with IEC-C13 receptacles or a combination of IEC-C13 plus IEC-C19 receptacles. The cable restraint system includes three tie-down brackets for receptacle groups along with cable ties to secure individual input user equipment power cables. Table 4 Cord sets and cable restraints - Liebert MPH Cord Sets and Cable Restraints Output Cord Sets - Power Output Conversion 539031G5 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 3.3 ft. (1m) 539031G6 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 10 ft. (3m) 539031G9 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 3.3 ft. (1m) 539031G10 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 10 ft. (3m) Input Cord Sets - Power Input Conversion 539031G12 Input Cord Set - Power Input Conversion - L5-20P to 5-20P, 1 ft. (0.3m) Cable Restraints IEC-C13 (Liebert MPH - Vertical Systems) 11858KIT Cable Restraints - MPH Vertical Systems with IEC-C13 receptacles 30 31 2 Input Plug 1 5 REAR VIEW 4 TOP VIEW 17.2" (438mm) 3 18.3" (465mm) FRONT VIEW 6 7 L5-20P 1 5-20R (9) Receptacle Type Branch (Quantity) OUTPUT POWER 10ft/3.0m 1 1 Phase 120 16 20 Per Branch Max Cont. Amps 16 Per Receptacle 20 MPH-NCR09AXXC30 Rev. 3 Voltage (VAC) Per Receptacle Type 120 8 HID16 1.7" [44mm 7.0" (178mm) 0.2" (6mm) L5-20P (2 Pole, 3 Wire) 1.2" (32mm) NOTES: 1. Unit Dimensions: 1.7" H x 7.0" D x 17.2" W (44mm x 178mm x 438mm) 2. Unit Weight: 7.5lb. (3.4kg) 3. Shipping Dimensions: 22.0" H x 9.0" D x 24.1" W (559mm x 228mm x 612mm) 4. Shipping Weight: 8.5lb. (3.9kg) 5. All wiring is to be in compliance with national and local electric codes. AGENCY: UL/C-UL Listed to UL60950-1 RoHS Compliant (Reduction of Hazardous Substances) ENVIROMENTAL: Operating: 32°F-131°F (0°C-55°C) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4°F-140°F (-20°C to 60°C) 9 RPC Communication Card Output Receptacles PN: RPC-1000 Input Cord Input Plug Phase Voltage (VAC) Rated Amps Max Cont. Amps INPUT POWER 20A Input Breaker Circ ui t Br eaker 20 Amp Audible Alarm Silence MPH Power Distribution 4.5 Li ebert Liebert MPH Product Selection Guide - Managed Rack PDUs Dimensional Drawings - Managed Rack PDUs Figure 23 Liebert MPH rack mount power strip B ranc h 1 C irc uit B reaker 20 Ampere 32 L5-20P 10 ft/3.0m 5-20R (9) 5-20R (9) 5-20R (9) 1 2 3 Receptacle Type (Quantity) Branch OUTPUT POWER Input Plug Input Cord INPUT POWER B ranc h 3 2 3 4 5 7 8 9 1 B ranc h 2 2 5 7 120 16 16 16 16 120 120 120 1 1 20 20 20 Phase Voltage (VAC) Per Receptacle Per Branch 1 9 SIDE VIEW Max Cont. Amps 20 8 1 B ranc h 1 2 3 4 5 6 7 Branch 3 (9) 5-20R 8 9 MPH P N: R PC -1000 3.4 (86mm) Toolless Mounting Button (See Note 6) 12.3 (312mm) P ower Dis tribution L iebert RPC Communication Card 1.2" (32mm) 0.2" (6mm) 1.9" (50mm) Vertical Mounting Bracket (See Note 6) HID16 MPH-NCV27AXXC30 Rev. 2 AGENCY: UL/C-UL Listed to UL60950-1 RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32°F to 131° F (0°C to 55° C) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4°F to 140°F (-20° C to 60° C) NOTES: 1. Unit Dimensions: 68.1" (1730mm) H x 3.1" (80mm) D x 1.9" (50mm) W 2. Unit Weight: 18lb. (8.2kg) 3. Shipping Dimensions: 72.2" (1962mm) H x 6.2" (159mm) D x 10.7" (273mm) W 4. Shipping Weight: 20lb. (9.1kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Only one mounting option required to be used at a time. Vertical mounting brackets and toolless buttons shown together for reference only. FRONT VIEW 6 68.1" (1730mm) 4 REAR VIEW 3 Branch 3 (9) 5-20R Voltage (VAC) Rated Amps Max Cont. Amps L5-20P (2 Pole, 3 Wire) Per Receptacle Type 1 6 2.2" (57mm) 20A Branch Circuit Breakers 1 Phase 9.2" (235mm) 3.1" (80mm) 0.99 (25mm) B ranc h 2 C irc uit B reaker 20 Ampere 3.4 (86mm) 12.3 (312mm) B ranc h 3 C irc uit B reaker 20 Ampere Branch 3 (9) 5-20R Liebert MPH Product Selection Guide - Managed Rack PDUs Figure 24 Liebert MPH vertical power strip Liebert MPX - Adaptive Rack PDUs 5.0 LIEBERT MPX - ADAPTIVE RACK PDUS 5.1 Overview - Adaptive Rack PDUs The Liebert MPX Adaptive Rack PDU system delivers break-through flexibility, availability and total cost of ownership. The Liebert MPX enables users to respond to and manage changing rack power and management environments. The Liebert MPX provides users the ability to size their Rack PDU system to support initial requirements and then adapt as connectivity, capacity and/or functionality needs change. The Liebert MPX is based on a patent-pending design built on a power / communication bus and input/output power module strategy. The Liebert MPX Adaptive Rack PDU is composed of several key building blocks and support modules. The Liebert MPX is built on the MPX PRC (Power Rail Chassis) that distributes power and communications to all support modules, acts as a backplane to mount support modules and offers provisions to physically mount the Liebert MPX in a network rack. Input power is connected and delivered to the Liebert MPX system via the MPX PEM (Power Entry Module). Output power connectivity and communications management level is defined by the MPX BRM (Branch Receptacle Modules). MPX BRM power connectivity includes NEMA receptacles and IEC sockets. MPX BRM communications include Branch Monitoring and Receptacle Management versions. Network communications, sensor and/or local display interface are provided by the Liebert RPC (Rack PDU Card) that mounts in the MPX PEM. The Liebert RPC provides connection to an optional RPC BDM (Basic Display Module) for local status / alarm viewing. Module versions for North American and European applications are available. The Liebert MPX is provided as separate ship-loose modules for user on-site configuration. The Liebert MPX is designed for simple and quick configuration and reconfiguration. Preconfigured systems are available as an Special Feature Authorization (SFA) when ordered as factory installed in Knurr rack enclosure systems. The major Liebert MPX system components are described in the following sections: • 5.2 - MPX PRC (Power Rail Chassis) • 5.3 - MPX PEM (Power Entry Module) and MPX IPC (Input Power Cord) • 5.4 - MPX BRM (Branch Receptacle Module) 33 Liebert MPX - Adaptive Rack PDUs Figure 25 Liebert MPX 1880 and 1035 models and components MPX BRM Liebert RPC MPX PEM, Variable Capacity Liebert MPX, 1035mm Liebert PRC chassis MPX PEM, Fixed Capacity Liebert MPX, 1880mm Liebert PRC chassis MPX IPC RPC BDM 34 Liebert MPX - Adaptive Rack PDUs 5.2 MPX PRC (Power Rail Chassis) The MPX PRC distributes power and communications to the installed Liebert MPX modules. The MPX PRC supports both single-phase power input up to 20A and three-phase up to 60A. It includes provisions to mount and secure an input power module (MPX PEM) and output receptacle modules (MPX BRM). It is available in lengths to accommodate typical 23U or 42U network racks: 1035mm (40.75 in.) for 23U and 1880mm (74 in.) for 42U. The MPX PRC includes zero-U mounting provisions that accommodate most rack designs. The MPX PRC is provided with cover / spacers to assist users with positioning for future MPX BRM module additions. Figure 26 MPX PRC (Power Rail Chassis) FRONT SIDE Section of MPX PRC Power Bus REAR SIDE Section of MPX PRC Communication Bus T-slots in the back of the MPX PRC (Power Rail Chassis) accept spring nuts for easy mounting Module Connector Slot 35 Liebert MPX - Adaptive Rack PDUs 5.3 MPX PEM (Power Entry Module) and MPX IPC (Input Power Cord) The MPX PEM provides input power to the Liebert MPX system and includes provisions for addition of the Liebert RPC (Rack PDU Card) to support remote and local communications. The MPX PEM is available in two versions: Variable Capacity and Fixed Capacity. The MPX PEM Variable Capacity version allows the user to select and change power input via different MPX IPCs. The MPX IPC includes cord, MPX PEM connector, and input plug. The MPX IPC is available in multiple versions supporting up to 30 amps including single-phase North American 120VAC and 208VAC and three-phase North American 208/120VAC connections. The MPX PEM Fixed Capacity version supports rated input capacities from 40 up to 60 amps with fixed cord and plug connections. All MPX PEMs include an audible over current alarm with local reset. One MPX PEM is required per Liebert MPX Rack PDU. • Variable Capacity MPX PEMs are 220mm in length for application on both short (1035mm) and standard (1880mm) MPX PRC systems. • Fixed Capacity systems are 266mm in length for application on standard (1880mm) MPX PRCs. 5.4 MPX BRM (Branch Receptacle Module) The MPX BRM provides output power distribution to user load equipment and remote management / monitoring of that equipment. The MPX BRM includes output receptacles (NEMA and IEC) and is overload-protected. The MPX BRM is available in two versions: Branch Monitoring and Receptacle Management. The MPX BRM Branch Monitoring version supports monitoring of its aggregate branch electrical and energy parameters (status, thresholds, and alarms) including voltage, amps, kW, and kW-hr. The MPX BRM Receptacle Management version supports monitoring of individual receptacle electrical and energy parameters (status, thresholds, and alarms)—including voltage, amps, kW and kW-hr—and supports on-off power control of individual receptacles, along with the aggregate branch monitoring provided on MPX BRM Branch Monitoring systems. MPX BRMs are hot-swappable to allow user installation without powering down the Liebert MPX system. Each MPX BRM includes a display that automatically assigns and displays a Branch identification number to the MPX BRM when added to an active Liebert MPX system. Each MPX BRM is overload-protected by 20 Amp branch-rated hydraulic magnetic circuit breakers that support UL60950 requirements. The breakers are protected from inadvertent tripping by requiring tool insertion to manually open and from accidental impact damage by a protection body/cover. MPX BRMs are offered in line-to-line and line-to-neutral power configurations. These configurations support different power input requirements and provide support for load balancing for three-phase input power systems. Up to three (3) MPX BRMs can be deployed on a Liebert MPX system utilizing the 1035mm MPX PRC for typical 23U racks and up to six (6) MPX BRMs for systems utilizing the 1880mm MPX PRC for typical 42U racks. All MPX BRMs are 266mm in length. 36 Liebert MPX - Adaptive Rack PDUs 5.5 Adaptive Rack PDU Optional Accessories 5.5.1 Cord Sets and Cable Restraints Output Cord Sets Output cord sets are available to support conversion of Rack PDU power output receptacles to alternative power output connections and to support Rack PDU output expansion capabilities. Conversion of power output connections can be provided on Rack PDUs with IEC-C19 receptacles. The output cord set for these systems includes an IEC-C20 plug to connect to the IEC-C19 receptacle, a 3 ft. (1m) power cord and receptacle to connect to user equipment. Available receptacles include: IEC-C13 to connect to IEC-C14 equipment plugs and IEC-C19 to connect to NEMA L6-20P equipment plugs. Cable Restraints (Liebert MPX Systems) Cable restraints are available to secure user equipment power cord connections to IEC-C13 receptacles. The Liebert MPX supports all models of the MPX BRM with IEC-C13 receptacles and includes individual cable restraint clips to support individual receptacles. Twelve restraint clips are provided per option. The Liebert MPX cable restraint supports most IEC-C14 plugs that connect to the IEC-C13 receptacles. Cord Sets and Cable Restraints Output Cord Sets - Power Output Conversion 539031G5 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 3 ft. (1m) 539031G6 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 10 ft. (3m) 539031G9 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 3 ft. (1m) 539031G10 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 10 ft. (3m) Cable Restraints IEC-C13 (Liebert MPX Systems) 039102169 5.5.2 Cable Restraints - MPX BRM with IEC-C13 receptacles (Set of 12) Liebert RPC™ (RPC-1000) and Accessories The Liebert RPC (Rack PDU Card) is a network interface card that provides network connectivity to the Liebert Rack PDU family of products. The Liebert RPC can be installed in Adaptive and Managed versions of Liebert Rack PDUs to provide network monitoring and control capabilities. The Liebert RPC is a factory-installed standard feature of the Liebert MPH; it is an option for the Liebert MPX. In addition, the Liebert RPC serves as the integration point for several rack accessory products. Available options that connect to the card include the RPC BDM (Basic Display Module) and a temperature/humidity sensor. 37 Liebert MPX - Adaptive Rack PDUs 5.5.3 Part Numbers for Liebert RPC and Accessories • Liebert RPC (Rack PDU Card): • RPC-1000 • RPC BDM (Basic Display Module): • RPC-BDM-1000 • Liebert SN Integrated Environmental Sensors: • SN-Z01 - Single Temperature Probe; 12 ft. (3.66m) length cable • SN-Z02 - Three Temperature Probes; 17 ft. (5.18m) length cable • SN-Z03 - Three Temperature Probes and Single Humidity Probe; 17 ft. (5.18m) length cable Liebert SN Modular Environmental Sensors: • SN-T - Single Temperature Probe (1 probe) • SN-TH - Single Temperature Probe and Single Humidity Probe (2 probes) • SN-2D - Door Switch, 2 inputs (1 probe) • SN-3C - Digital Input, 3 inputs (1 probe) 5.5.4 Ports on the Liebert RPC Figure 27 shows the four individual ports on the Liebert RPC. Each port is designed for only one type of connection. See the Liebert RPC user manual, SL-20825, for details on using these ports. Figure 27 Liebert RPC ports External Sensor port Display port Expansion/Management port LAN port 38 Liebert MPX - Adaptive Rack PDUs 5.5.5 Liebert RPC Capabilities and Benefits The Liebert RPC offers the following capabilities and benefits: Web Support The Liebert RPC delivers Web management and control to Liebert Rack PDU equipment. All authorized users will be able to view status information on their network. SNMP Support The Liebert RPC enables SNMP management of Liebert Rack PDU equipment. To integrate the card into an SNMP implementation, compile the Liebert Global Products MIB on your Network Management System (NMS). The Liebert Global Products MIB can be downloaded from: www.liebert.com Liebert Nform™ Utilizing the SNMP and Web technologies built into the Liebert RPC, Liebert Nform will centrally manage event notifications, access critical system information and manage the power delivered to your critical devices. A downloadable edition is available online at: nform.liebert.com Liebert SiteScan® Web The Liebert RPC integrates with Liebert SiteScan Web software to monitor and analyze trends to ensure high-availability operation of critical facilities. For more information on Liebert SiteScan Web, visit the Web page at: sitescan.liebert.com 39 Liebert MPX - Adaptive Rack PDUs 5.5.6 RPC BDM—Basic Display Module The RPC BDM is an optional device with an LCD for local viewing of status and alarms of up to four Liebert MPX or Liebert MPH PDUs. It connects to Liebert RPC with a factory-supplied cable that is 6.5 ft. (2m) long. The portable unit can be mounted on a wall for viewing particular units. The RPC BDM provides local display of electrical status for all connected Liebert MPX (and Liebert MPH) systems, MPX BRMs and individual receptacles, if the PDU version permits it. Information is accessed via a navigation switch on the RPC BDM. For model number and other details, refer to 5.5.3 - Part Numbers for Liebert RPC and Accessories and the Liebert RPC user manual, SL-20825, available at the Liebert Web site: www.liebert.com Figure 28 RPC BDM Jog Wheel on Top of Unit to Navigate Display Communication Port on Side of Unit Connects to Liebert RPC RPC BDM 5.5.7 Temperature/Humidity Sensor A temperature/humidity sensor is available to monitor conditions in the rack. The sensor mounts without tools. It connects to the Liebert RPC with a factory-supplied Ethernet cable and can be monitored over a network. Figure 29 Temperature/humidity sensor Sensor support Tool-less fastener Sensor Sensor Knurr frame member Support base Sensor installed in rack 40 Liebert MPX System Product Selection Guide 6.0 LIEBERT MPX SYSTEM PRODUCT SELECTION GUIDE 6.1 STEP 1 - Select an MPX PRC (Quantity x 1) To select an MPX PRC (Power Rail Chassis), refer to: Specifications - MPX PRC MPXPRC-V1035XXX: Input: Rack Fit: MPXPRC-V1880XXX: Input: Rack Fit: Max 8.6 kW, limited to 3 MPX BRM modules Single-Phase and Three-Phase 5-wire / 20-30 Amp / 120/208VAC Typical 23U, most 600mm wide Max 17.2 kW, limited to 6 MPX BRM modules Single-Phase and Three-Phase 5-wire / 20-60 Amp / 120/208VAC Typical 42U, most 600mm wide Model Number Configuration - MPX PRC Example: MPXPRC-V1035XXX • Prefix: • Mounting: • Length: MPXPRC V = Vertical 1035 = Short (40.75"; 1035mm) 1880 = Standard (74"; 1880mm) • Placeholder: XXX Liebert MPX with 1035mm Liebert PRC chassis Liebert MPX with 1880mm Liebert PRC chassis 41 Liebert MPX System Product Selection Guide 6.2 STEP 2 - Select an MPX PEM / MPX IPC (Quantity x 1) To select an MPX PEM (Power Entry Module)—and an MPX IPC (Input Power Cord) for a Variable Capacity MPX PEM system—refer to: • The appropriate table in 6.5 - System Selection Guide for the MPX PEM (Power Entry Module): • Table 5 - Selections for Power Entry Module MPXPEM-NVAXXAXX • Table 6 - Selections for Power Entry Module MPXPEM-NHBXXV30 • Table 7 - Selections for Power Entry Module MPXPEM-NHBXXX30 • Table 8 - Selections for Power Entry Module MPXPEM-NHBXXW30 • The following information: Input Power MPX PEM Selection MPX IPC Input Plug 120VAC / 1-Phase / 30 Amp MPXPEM-NVAXXAXX MPXIPC-NXD30XXX L5-30P 208VAC / 1-Phase / 30 Amp MPXPEM-NVAXXAXX MPXIPC-NXF30XXX L6-30P 208VAC / 3-Phase / 30 AMP MPXPEM-NVAXXAXX MPXIPC-NXJ30XXX L15-30P 120/208VAC / 3-Phase / 20 Amp MPXPEM-NVAXXAXX MPXIPC-NXG30XXX L21-20P 120/208VAC / 3-Phase / 30 Amp MPXPEM-NVAXXAXX MPXIPC-NXH30XXX L21-30P Specifications - MPX PEM MPX PEM (Power Entry Module) MPXPEM-NVAXXAXX Power Entry Module - Variable Capacity, North American, 120 or 208VAC single-phase and/or 208-240VAC three-phase input up to 30Amp MPXPEM-NHBXXV30 Power Entry Module - Fixed Capacity, North American, 208-240VAC, three-phase 4-wire (L-L-L-G), 50Amp input, CS8365C plug, 10 ft. (3m) cord MPXPEM-NHBXXX30 Power Entry Module - Fixed Capacity, North American, 208-240VAC, three-phase 4-wire (L-L-L-G), 60Amp input, IEC60309 Pin-Sleeve plug, 10 ft. (3m) cord MPXPEM-NHBXXW30 Power Entry Module - Fixed Capacity, North American, 120/208VAC, three-phase 5-wire (L-L-L-N-G), 60Amp input, IEC60309 Pin-Sleeve plug, 10 ft. (3m) cord Model Number Configuration - MPX PEM Example: MPXPEM-NVAXXAXX • Prefix: • Region: • Type: MPXPEM N = North American V = Variable Capacity H = Fixed Capacity • Size: A = Base (220mm) – Variable Capacity version B = Standard (266mm) – Fixed Capacity version • Communications: X = Future Use • Input Power: • Available Capacity or Plug Type: XA = 30 amps XV = 50 amps, 4-wire (CS8365C) XX = 60 amps, 4-wire (IEC60309) XW = 60 amps, 5-wire (IEC60309) • Cord Length: XX = No integrated cord (Requires MPX IPC) 30 = 3.0m (10 ft.) 42 MPX PEM, Variable Capacity MPX PEM, Fixed Capacity Liebert MPX System Product Selection Guide Specifications - MPX IPC (MPX PEM Variable Capacity Systems ONLY) MPX IPC (Input Power Cord) 120VAC – Single-Phase Input / Output MPXIPC-NXD30XXX Input Power Cord - North American, 30Amp - 120VAC - Single-Phase; NEMA L5-30P Locking plug; 10 ft. (3m) length cord 208VAC – Single-Phase Input / Output MPXIPC-NXF30XXX Input Power Cord - North American, 30Amp - 208-240VAC - Single-Phase; NEMA L6-30P Locking plug; 10 ft. (3m) length cord 208VAC – Three-Phase Input / 208VAC Single-Phase Output MPXIPC-NXJ30XXX Input Power Cord - North American, 30Amp - 208-240VAC - Three-Phase, 4-wire; NEMA L15-30P Locking plug; 10 ft. (3m) length cord 208VAC – Three-Phase Input / 120/208VAC Single-Phase Output MPXIPC-NXG30XXX Input Power Cord - North American, 20Amp - 120/208VAC - Three-Phase; NEMA L21-20P Locking plug; 10 ft. (3m) length cord MPXIPC-NXH30XXX Input Power Cord - North American, 30Amp - 120/208VAC - Three-Phase; NEMA L21-30P Locking plug; 10 ft. (3m) length cord Model Number Configuration - MPX IPC (MPX PEM Variable Capacity Systems ONLY) Example: MPXIPC-NXG30XXX • Prefix: MPXIPC • Region: N = North American • Input Power and Connection: • Plug Type: XD = L5-30P XF = L6-30P XJ = L15-30P XG = L21-20P XH = L21-30P • Cord Length: 30 = 3.0m (10 ft.) • Placeholder: XXX MPX PEM, Variable Capacity MPX IPC 43 Liebert MPX System Product Selection Guide 6.3 STEP 3 - Select an MPX BRM To select an MPX BRM (Branch Receptacle Module), refer to: • The appropriate table in 6.5 - System Selection Guide for the MPX PEM (Power Entry Module): • Table 5 - Selections for Power Entry Module MPXPEM-NVAXXAXX • Table 6 - Selections for Power Entry Module MPXPEM-NHBXXV30 • Table 7 - Selections for Power Entry Module MPXPEM-NHBXXX30 • Table 8 - Selections for Power Entry Module MPXPEM-NHBXXW30 • The following MPX BRM quantity definitions: MPX PRC selected Single-Phase Input Three-Phase Input MPXPRC-V1035XXX 3 MPX BRM modules maximum 1 x BRM per Lx-Lx* (total 3 max) MPXPRC-V1035XXX 6 MPX BRM modules maximum 2 x BRM per Lx-Lx* (total 6 max) * Required for phase load balancing • If needed, refer to the MPX BRM specifications in Table 9 Model Number Configuration - MPX BRM Example: MPXBRM-NRBD4O31 • Prefix: • Region: • Type: MPXBRM N = North American B = Branch Monitoring R = Receptacle Management • Size and OL Protection: • Size: B = Standard (266mm) • Voltage Rating and OL Protection: A = 120V/20A D = 208-240V/20A • Output Power: • Quantity Receptacles: 4, 6 • Receptacle Type: A = 5-20R T-slot N = IEC-C13 O = IEC-C19 • Phase Configuration: 1N = L1-N 2N = L2-N 3N = L3-N 12 = L1-L2 23 = L2-L3 31 = L3-L1 44 MPX BRM Liebert MPX System Product Selection Guide 6.4 STEP 4 - Select Communication Options Choose from the following options for the Liebert MPX: • Liebert RPC (Rack PDU Card) part number: • RPC-1000 • RPC BDM (Basic Display Module) part number: • RPC-BDM-1000 • Liebert SN Integrated and Modular Environmental Sensor part numbers: Integrated Sensors • SN-Z01 - Single Temperature Probe; 12 ft. (3.66m) length cable • SN-Z02 - Three Temperature Probes; 17 ft. (5.18m) length cable • SN-Z03 - Three Temperature Probes and Single Humidity Probe; 17 ft. (5.18m) length cable Modular Sensors • SN-T - Single Temperature Probe (1 probe) • SN-TH - Single Temperature Probe and Single Humidity Probe (2 probes) • SN-2D - Door Switch, 2 inputs (1 probe) • SN-3C - Digital Input, 3 inputs (1 probe) Liebert RPC RPC BDM The Liebert RPC is required for the other two options, the RPC BDM and Liebert SN integrated sensor. Liebert SN (Integrated Sensor) Liebert SN (Modular Sensor) 45 Liebert MPX System Product Selection Guide 6.5 System Selection Guide Use the appropriate table as a guide to select components that are compatible with each MPX PEM: • • • • Table 5 Table 5 - Selections for Power Entry Module MPXPEM-NVAXXAXX Table 6 - Selections for Power Entry Module MPXPEM-NHBXXV30 Table 7 - Selections for Power Entry Module MPXPEM-NHBXXX30 Table 8 - Selections for Power Entry Module MPXPEM-NHBXXW30 Selections for Power Entry Module MPXPEM-NVAXXAXX MPX PEM Part Number Module Voltage Rated Amps Max. Continuous Amps Input Connection Input Phases Module Length (mm) MPXPEM-NVAXXAXX* 120/208 or 208-240 30 24 Variable Single-Phase or Three-Phase depending on the MPX IPC selection 220 Max. # MPX BRMs Supported Phase Configuration Overall Length 1035mm, 23U 6 Single-Phase & Three-Phase 1880mm, 42U Cord Length ft. (m) * No fixed cord (requires MPX IPC) Compatible MPX PRC for given MPX PEM: Voltages Supported Rated Amps Max. Continuous Amps MPXPRC-V1035XXX 120/208 or 208-240 60 48 Voltages Supported Rated Amps Max. Continuous Amps Input Plug Phase Configuration 120 30 24 NEMA L5-30P L1-N-G 10 (3.0) Module Voltage Branch Rated Amps Max. Continuous Amps Quantity & Receptacle Type Output Phase Configuration Module Length (mm) 120V 20 16 (6) NEMA 5-20R L1-N 266 120V 20 16 (6) NEMA 5-20R L1-N 266 Voltages Supported Rated Amps Max. Continuous Amps Input Plug Phase Configuration Cord Length ft. (m) MPXIPC-NXF30XXX 208-240 30 24 NEMA L6-30P L1-L2-G 10 (3.0) Compatible MPX BRM for given MPX IPC: Module Voltage Branch Rated Amps Max. Continuous Amps Quantity & Receptacle Type Output Phase Configuration Module Length (mm) MPXBRM-NBBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266 MPXBRM-NRBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266 MPXPRC-V1880XXX Compatible MPX IPC for given MPX PEM: MPXIPC-NXD30XXX Compatible MPX BRM for given MPX IPC: 3 Branch Monitoring MPXBRM-NBBA6A1N Receptacle Management MPXBRM-NRBA6A1N Compatible MPX IPC for given MPX PEM: Branch Monitoring Receptacle Management 46 Liebert MPX System Product Selection Guide Table 5 Selections for Power Entry Module MPXPEM-NVAXXAXX (continued) Voltages Supported Rated Amps Max. Continuous Amps Input Plug Phase Configuration Cord Length ft. (m) MPXIPC-NXJ30XXX 208-240 30 24 NEMA L15-30P L1-L2-L3-G 10 (3.0) Compatible MPX BRM for given MPX IPC: Module Voltage Branch Rated Amps Max. Continuous Amps Quantity & Receptacle Type Output Phase Configuration Module Length (mm) MPXBRM-NBBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266 MPXBRM-NBBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266 MPXBRM-NBBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266 MPXBRM-NBBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266 MPXBRM-NBBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266 MPXBRM-NRBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266 Compatible MPX IPC for given MPX PEM: Branch Monitoring Receptacle Management MPXBRM-NRBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266 MPXBRM-NRBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266 MPXBRM-NRBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266 MPXBRM-NRBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266 Voltages Supported Rated Amps Max. Continuous Amps Input Plug Phase Configuration Cord Length ft. (m) Compatible MPX IPC for given MPX PEM: MPXIPC-NXG30XXX 120/208 20 16 NEMA L21-20P L1-L2-L3-N-G 10 (3.0) Module Voltage Branch Rated Amps Max. Continuous Amps Quantity & Receptacle Type Output Phase Configuration Module Length (mm) MPXBRM-NBBA6A1N 120V 20 16 (6) NEMA 5-20R L1-N 266 MPXBRM-NBBA6A2N 120V 20 16 (6) NEMA 5-20R L2-N 266 MPXBRM-NBBA6A3N 120V 20 16 (6) NEMA 5-20R L3-N 266 MPXBRM-NBBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266 MPXBRM-NBBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266 MPXBRM-NBBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266 MPXBRM-NBBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266 MPXBRM-NBBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266 MPXBRM-NRBA6A1N 120V 20 16 (6) NEMA 5-20R L1-N 266 MPXBRM-NRBA6A2N 120V 20 16 (6) NEMA 5-20R L2-N 266 MPXBRM-NRBA6A3N 120V 20 16 (6) NEMA 5-20R L3-N 266 MPXBRM-NRBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266 MPXBRM-NRBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266 MPXBRM-NRBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266 MPXBRM-NRBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266 MPXBRM-NRBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266 Compatible MPX BRM for given MPX IPC: Branch Monitoring Receptacle Management 47 Liebert MPX System Product Selection Guide Table 5 Selections for Power Entry Module MPXPEM-NVAXXAXX (continued) Voltages Supported Rated Amps Max. Continuous Amps Input Plug Phase Configuration Cord Length ft. (m) MPXIPC-NXH30XXX 120/208 30 24 NEMA L21-30P L1-L2-L3-N-G 10 (3.0) Compatible MPX BRM for given MPX IPC: Module Voltage Branch Rated Amps Max. Continuous Amps Quantity & Receptacle Type Output Phase Configuration Module Length (mm) MPXBRM-NBBA6A1N 120V MPXBRM-NBBA6A2N 120V 20 16 (6) NEMA 5-20R L1-N 266 20 16 (6) NEMA 5-20R L2-N 266 MPXBRM-NBBA6A3N 120V 20 16 (6) NEMA 5-20R L3-N 266 MPXBRM-NBBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266 MPXBRM-NBBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266 MPXBRM-NBBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266 MPXBRM-NBBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266 MPXBRM-NBBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266 MPXBRM-NRBA6A1N 120V 20 16 (6) NEMA 5-20R L1-N 266 MPXBRM-NRBA6A2N 120V 20 16 (6) NEMA 5-20R L2-N 266 MPXBRM-NRBA6A3N 120V 20 16 (6) NEMA 5-20R L3-N 266 MPXBRM-NRBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266 MPXBRM-NRBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266 MPXBRM-NRBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266 MPXBRM-NRBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266 MPXBRM-NRBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266 Compatible MPX IPC for given MPX PEM: Branch Monitoring Receptacle Management 48 Liebert MPX System Product Selection Guide Table 6 Selections for Power Entry Module MPXPEM-NHBXXV30 Input Connection Input Phases Module Length (mm) 40 CS83665C 3-PH, 4-Wire L1-L2-L3-G 266 Rated Amps Max. Continuous Amps Max. # MPX BRMs Supported Phase Configuration Overall Length 60 48 1035mm, 23U 6 Single-Phase & Three-Phase Module Voltage Branch Rated Amps Max. Continuous Amps Quantity & Receptacle Type Output Phase Configuration Module Length (mm) MPXBRM-NBBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266 MPXBRM-NBBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266 MPXBRM-NBBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266 MPXBRM-NBBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266 MPXBRM-NBBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266 MPXBRM-NRBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266 MPXBRM-NRBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266 MPXBRM-NRBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266 MPXBRM-NRBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266 MPXBRM-NRBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266 MPX PEM Part Number MPXPEM-NHBXXV30 Compatible MPX PRC for given MPX PEM: MPXPRC-V1035XXX MPXPRC-V1880XXX Compatible MPX BRM for given MPX PEM: Module Voltage Rated Amps Max. Continuous Amps 208-240V 50 Voltages Supported 120/208 or 208-240 3 1880mm, 42U Branch Monitoring Receptacle Management 49 Liebert MPX System Product Selection Guide Table 7 Selections for Power Entry Module MPXPEM-NHBXXX30 Input Connection Input Phases Module Length (mm) 48 IEC60309 3-PH, 4-Wire L1-L2-L3-G 266 Rated Amps Max. Continuous Amps Max. # MPX BRMs Supported Phase Configuration Overall Length 60 48 1035mm, 23U 6 Single-Phase & Three-Phase Module Voltage Branch Rated Amps Max. Continuous Amps Quantity & Receptacle Type Output Phase Configuration Module Length (mm) MPXBRM-NBBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266 MPXBRM-NBBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266 MPXBRM-NBBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266 MPXBRM-NBBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266 MPXBRM-NBBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266 MPXBRM-NRBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266 MPXBRM-NRBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266 MPXBRM-NRBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266 MPXBRM-NRBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266 MPXBRM-NRBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266 MPX PEM Part Number MPXPEM-NHBXXX30 Compatible MPX PRC for given MPX PEM: MPXPRC-V1035XXX MPXPRC-V1880XXX Compatible MPX BRM for given MPX PEM: Module Voltage Rated Amps Max. Continuous Amps 208-240V 60 Voltages Supported 120/208 or 208-240 3 1880mm, 42U Branch Monitoring Receptacle Management 50 Liebert MPX System Product Selection Guide Table 8 Selections for Power Entry Module MPXPEM-NHBXXW30 Input Connection Input Phases Module Length (mm) 48 IEC60309 3-PH, 5-Wire L1-L2-L3-N-G 266 Rated Amps Max. Continuous Amps Max. # MPX BRMs Supported Input Phases Overall Length 60 48 1035mm, 23U 6 Single-Phase & Three-Phase Module Voltage Branch Rated Amps Max. Continuous Amps Quantity & Receptacle Type Output Phase Configuration Module Length (mm) MPXBRM-NBBA6A1N 120V 20 16 (6) NEMA 5-20R L1-N 266 MPXBRM-NBBA6A2N 120V 20 16 (6) NEMA 5-20R L2-N 266 MPXBRM-NBBA6A3N 120V 20 16 (6) NEMA 5-20R L3-N 266 MPXBRM-NBBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266 MPXBRM-NBBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266 MPXBRM-NBBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266 MPXBRM-NBBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266 MPXBRM-NBBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266 MPXBRM-NRBA6A1N 120V 20 16 (6) NEMA 5-20R L1-N 266 MPXBRM-NRBA6A2N 120V 20 16 (6) NEMA 5-20R L2-N 266 MPXBRM-NRBA6A3N 120V 20 16 (6) NEMA 5-20R L3-N 266 MPXBRM-NRBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266 MPXBRM-NRBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266 MPXBRM-NRBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266 MPXBRM-NRBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266 MPXBRM-NRBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266 MPX PEM Part Number MPXPEM-NHBXXW30 Compatible MPX PRC for given MPX PEM: MPXPRC-V1035XXX MPXPRC-V1880XXX Compatible MPX BRM for given MPX PEM: Module Voltage Rated Amps Max. Continuous Amps 208-240V 60 Voltages Supported 120/208 or 208-240V 3 1880mm, 42U Branch Monitoring Receptacle Management 51 Liebert MPX System Product Selection Guide 6.6 Table 9 Specifications for Liebert MPX Components Specifications - MPX BRM MPX BRM (Branch Receptacle Module) Single-Phase Liebert MPX System (MPX PEM) Input Selections Phase L1 to Neutral (120VAC) Output Branch Monitoring Support MPXBRM-NBBA6A1N Branch Monitoring, (6) NEMA 5-20R (T-slot) receptacles; Line L1 to Neutral (120VAC) Receptacle Management Support MPXBRM-NRBA6A1N Receptacle Management, (6) NEMA 5-20R (T-slot) receptacles; Line L1 to Neutral (120VAC) Line L1 to L2 (208VAC) Output Branch Monitoring Support MPXBRM-NBBD6N12 Branch Monitoring, (6) IEC-C13 receptacles; Line L1 to L2 (208-240VAC) MPXBRM-NBBD4O12 Branch Monitoring, (4) IEC-C19 receptacles; Line L1 to L2 (208-240VAC) Receptacle Management Support MPXBRM-NRBD6N12 Receptacle Management, (6) IEC-C13 receptacles; Line L1 to L2 (208-240VAC) MPXBRM-NRBD4O12 Receptacle Management, (4) IEC-C19 receptacles; Line L1 to L2 (208-240VAC) Three-Phase Liebert MPX System (MPX PEM) Input Selections Line L1 to L2 (208VAC) or Phase L1 to Neutral (120VAC) Output Branch Monitoring Support MPXBRM-NBBA6A1N Branch Monitoring, (6) NEMA 5-20R (T-slot) receptacles; Phase L1 to Neutral (120VAC) MPXBRM-NBBD6N12 Branch Monitoring, (6) IEC-C13 receptacles; Line L1 to L2 (208-240VAC) MPXBRM-NBBD4O12 Branch Monitoring, (4) IEC-C19 receptacles Line L1 to L2 (208-240VAC) Receptacle Management Support MPXBRM-NRBA6A1N Receptacle Management, (6) NEMA 5-20R (T-slot) receptacles; Phase L1 to Neutral (120VAC) MPXBRM-NRBD6N12 Receptacle Management, (6) IEC-C13 receptacles; Line L1 to L2 (208-240VAC) MPXBRM-NRBD4O12 Receptacle Management, (4) IEC-C19 receptacles Line L1 to L2 (208-240VAC) Line L2 to L3 (208VAC) or Phase L2 to Neutral (120VAC) Output Branch Monitoring Support MPXBRM-NBBA6A2N Branch Monitoring, (6) NEMA 5-20R (T-slot) receptacles; Phase L2 to Neutral (120VAC) MPXBRM-NBBD6N23 Branch Monitoring, (6) IEC-C13 receptacles; Line L2 to L3 (208-240VAC) MPXBRM-NBBD4O23 Branch Monitoring, (4) IEC-C19 receptacles Line L2 to L3 (208-240VAC) Receptacle Management Support MPXBRM-NRBA6A2N Receptacle Management, (6) NEMA 5-20R (T-slot) receptacles; Phase L2 to Neutral (120VAC) MPXBRM-NRBD6N23 Receptacle Management, (6) IEC-C13 receptacles Line L2 to L3 (208-240VAC) MPXBRM-NRBD4O23 Receptacle Management, (4) IEC-C19 receptacles Line L2 to L3 (208-240VAC) Line L3 to L1 (208VAC) or Phase L3 to Neutral (120VAC) Output Branch Monitoring Support MPXBRM-NBBA6A3N Branch Monitoring, (6) NEMA 5-20R (T-slot) receptacles; Phase L3 to Neutral (120VAC) MPXBRM-NBBD6N31 Branch Monitoring, (6) IEC-C13 receptacles; Line L3 to L1 (208-240VAC) MPXBRM-NBBD4O31 Branch Monitoring, (4) IEC-C19 receptacles Line L3 to L1 (208-240VAC) Receptacle Management Support MPXBRM-NRBA6A3N Receptacle Management, (6) NEMA 5-20R (T-slot) receptacles; Phase L3 to Neutral (120VAC) MPXBRM-NRBD6N31 Receptacle Management, (6) IEC-C13 receptacles Line L3 to L1 (208-240VAC) MPXBRM-NRBD4O31 Receptacle Management, (4) IEC-C19 receptacles Line L3 to L1 (208-240VAC) 52 2.9" (75mm) 53 2.9" (75mm) 4.1" (104mm) MPX-PRC cover/spacer MPX-BRM circuit breaker protection body MPX-PRC (Power Rail Chassis) SIDE VIEW MPX-BRM (Branch Receptacle Modules) TOP VIEW 40.6" (1035mm) 10.5" (266mm) 8.7" (220mm) 4.1" (104mm) Input power cord (variable) MPX-MIXMOD1035 Rev. 0 NOTES: 1. Dimensional view of 1035mm MPX-PRC application. 2. Representative module mix may not reflect user selection. 3. Operating temperature: 41°F to 131°F (5°C to 55°C) 4. Storage temperature: -13°F to 185°F (-25°C to 85°C ) MPX-PEM (Power Entry Module) 10.5" (266mm) 6.7 10.5" (266mm) Liebert MPX System Product Selection Guide Dimensional Drawings - Adaptive Rack PDUs Figure 30 Liebert MPX MPXPRC-1035mm mixed modules 54 2.9" (75mm) END VIEW 2.9" (75mm) 4.1" (104mm) MPX-PRC cover/spacer 10.5" (266mm) MPX-PRC (Power Rail Chassis) 4.1" (104mm) 10.5" (266mm) TOP VIEW 74" (1880mm) 10.5" (266mm) SIDE VIEW MPX-BRM (Branch Receptacle Modules) 10.5" (266mm) MPX-MIXMOD1880 Rev. 1 NOTES: 1. Dimensional view of 1880mm MPX-PRC application. 2. Representative module mix may not reflect user selection. 3. Operating temperature: 41°F to 131°F (5°C to 55°C) 4. Storage temperature: -13°F to 185°F (-25°C to 85°C ) 4.1" (104mm) MPX-PEM (Power Entry Module) 10.5" (266mm) Input power cord (fixed) 10.5" (266mm) MPX-BRM circuit breaker protection body 10.5" (266mm) Liebert MPX System Product Selection Guide Figure 31 Liebert MPX MPXPRC-1880mm mixed modules Ensuring The High Availability Of Mission-Critical Data And Applications. Emerson Network Power, the global leader in enabling business-critical continuity, ensures network resiliency and adaptability through a family of technologies—including Liebert power and cooling technologies—that protect and support business-critical systems. Liebert solutions employ an adaptive architecture that responds to changes in criticality, density and capacity. Enterprises benefit from greater IT system availability, operational flexibility and reduced capital equipment and operating costs. Technical Support / Service Web Site www.liebert.com Monitoring [email protected] 800-222-5877 Outside North America: +00800 1155 4499 Single-Phase UPS & Server Cabinets [email protected] 800-222-5877 Outside North America: +00800 1155 4499 Three-Phase UPS & Power Systems 800-543-2378 Outside North America: 614-841-6598 Environmental Systems 800-543-2778 Outside the United States: 614-888-0246 Locations United States 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229 Europe Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco (PD) Italy +39 049 9719 111 Fax: +39 049 5841 257 Asia 29/F, The Orient Square Building F. Ortigas Jr. Road, Ortigas Center Pasig City 1605 Philippines +63 2 687 6615 Fax: +63 2 730 9572 While every precaution has been taken to ensure the accuracy and completeness of this literature, Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions. © 2009 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. ® Liebert is a registered trademark of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners. SL-20828_REV1_02-11 Emerson Network Power. The global leader in enabling Business-Critical Continuity™ AC Power Connectivity Embedded Computing Embedded Power DC Power Infrastructure Management & Monitoring Outside Plant Power Switching & Controls Precision Cooling EmersonNetworkPower.com Racks & Integrated Cabinets Services Surge Protection Emerson, Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks of Emerson Electric Co. or one of its affiliated companies. ©2010 Emerson Electric Co.