WRA-ZMD-20W

WRA-ZMD-20W&WRB-ZMD -20W Series
20
W, WIDE INPUT, ISOLATED & REGULATED DUAL/SINGLE OUTPUT DC
20W,
DC--DC CONVERTER
SELECTION GUIDE
Order code
Input voltage
range
Output voltage
Output
current max.
Efficiency typ.
WRB2403ZMD-5500
9 – 36 VDC
3.3 VDC
5500 mA
85 %
WRB2405ZMD-20W
9 – 36 VDC
5 VDC
4000 mA
88 %
WRB2412ZMD-20W
9 – 36 VDC
12 VDC
1670 mA
86 %
WRB2415ZMD-20W
9 – 36 VDC
15 VDC
1330 mA
86 %
WRA2405ZMD-20W
9 – 36 VDC
± 5 VDC
± 2000 mA
88 %
WRA2412ZMD-20W
9 – 36 VDC
± 12 VDC
± 835 mA
87 %
WRA2415ZMD-20W
9 – 36 VDC
± 15 VDC
± 665 mA
87 %
WRB4803ZMD-5500
18 – 75 VDC
3.3 VDC
5500 mA
85 %
–40℃ to +85℃ max.
WRB4805ZMD-20W
18 – 75 VDC
5 VDC
4000 mA
88 %
No minimum load required
WRB4812ZMD-20W
18 – 75 VDC
12 VDC
1670 mA
87 %
WRB4815ZMD-20W
18 – 75 VDC
15VDC
1330 mA
87 %
I/O-isolation 1500 VDC
WRA4805ZMD-20W
18 – 75 VDC
± 5 VDC
± 2000 mA
89 %
Remote On/Off
WRA4812ZMD-20W
18 – 75 VDC
± 12 VDC
± 835 mA
88 %
WRA4815ZMD-20W
18 – 75 VDC
± 15 VDC
± 665 mA
88 %
FEATURES
High power density in 1" x 2" metal package
◆
Ultra wide 4 : 1 input range
◆
Extended operating temperature range
◆
◆
◆
◆
Adjustable output voltage
◆
Industry standard footprint
◆
Shielded metal case with insulated baseplate
◆
Input Specifications
Optional heatsink
◆
Lead free design - RoHS compliant
◆
Input current at no load
3-year product warranty
◆
Input current at full load
MODEL SELECTION
①
②
③ ④
⑤ ⑥
⑦
WRB 24 12 Z M D -20W(1670)
①Product Series
②Input Voltage
③Output Voltage ④Wide (4:1) Input Range
⑤Metal Shield ⑥2" x 1"DIP Package Style
⑦Rated Power(Output current)
APPLICATIONS
24 Vin models:
50 mA typ.
48 Vin models:
35 mA typ.
24 Vin models:
1000 mA typ.
48 Vin models:
500 mA typ.
Surge voltage
24 Vin models:
50 V max.
(100 msec. max.)
48 Vin models:
100 V max.
5 V / ms, max.
Input voltage variation (dv/df)
(complies to ETS 300 132 part. 4.4)
Start-up voltage / under voltage
24 Vin models:
9 VDC / 7.5 VDC typ.
lockout
48 Vin models:
18 VDC / 15 VDC typ.
EN 55022 level A, FCC part 15, level A with
Conducted noise(input)
The WRA-ZMD-20W & WRB-ZMD-20W
Series is a family of high performance 20W
DC/DC converter modules featuring ultra wide
4:1 input voltage ranges in a ultra compact
2“x1“ low profile package with industry-standard
footprint. A very high efficiency al-lows an
operating temperature range of –40°C to 85°C.
Further standard features include remote On/Off,
output voltage trimming,over voltage protection
and short-circuit protection.
Typical applications for these converters are
battery operated equipment and distributed
power architectures in communication and
industrial electronics,everywhere where isolated,
tightly regulated voltages are required.
external capacitor (see application note)
ESD (input)
EN 61000-4-2, perf. criteria B
Fast transient (input)
EN 61000-4-4, perf. criteria B
Surge (input)
EN 61000-4-5, perf. criteria B
General Specifications
Reliability, calculated MTBF
(MIL-HDBK-217F
ground benign)
Isolation voltage (60 sec.)
– Input/Output
1500 VDC
Isolation capacity
– Input/Output
1500 pF max
Isolation resistance
– Input/Output
>1000 M Ohm
Switching frequency (fixed)
400 kHz typ. (pulse width modulation PWM)
Vibration
Remote On/Off
MICRODC RESERVES THE COPYRIGHT
Safety standards
http://www.microdc.cn
>560000 h @ + 25 °C
10-55Hz, 10G, 30 minutes along X,Y,Z
– On:
3.0 to 12 VDC or open circuit.
– Off:
0 to 1.2 VDC or short circuit pin 2 and pin 6
– Off idle current:
2.5 mA typ.
UL 60950
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 1 of 3
WRA-ZMD-20W&WRB-ZMD -20W Series
Output Specifications
Voltage set accuracy
±1 %
Output voltage
±10 % by external resistor, see application note:
(single output models only)
adjustment
http://www.microdc.cn/uploadfiles/WRA-ZMD-20W&WRB-ZMD-20W.pdf
– Input variation Vin min. to Vin max.
0.2 % max.
– Load variation 0 – 100%:
Regulation
single output models:
dual output models:
– Load cross variation 25 % / 100 %
0.5 % max.
1 % max. (balanced load)
5 % max.
Temperature coefficient
0.02 % /K
(20 MHz Bandwidth)
Ripple and noise
single output models:
75 mVpk-pk max.
dual output models:
100 mVpk-pk max.
Start up time
(nominal Vin and constant resistive load)
20 ms typ.
Transient Response
(25% load step change)
20 ms typ.
Transient Response
(25% load step change)
250 µs typ.
Short circuit protection
indefinite (automatic recovery)
Over load protection
150% of Iout max typ.
3.3 Vout models:
5 /±5 Vout models:
Over voltage protection
15 / ±15 V
15 /±15 Vout models:
18 / ±18 V
5 Vout models / ± 5 Vout models:
9600 µF max. / ± 4800 µF max.
1600 µF max. / ± 800 µF max.
15 Vout models / ±15 Vout models:
1000 µF max. / ± 500 µF max.
Physical Specifications
– Operating
–40 °C to +85 °C
– Case temperature
+105 °C max.
– Storage
–55 °C to +125 °C
Humidity (non condensing)
18’000 µF max.
12 Vout models / ±12 Vout models:
General Specifications
Temperature ranges
6.2 / ±6.2 V
12 /±12 Vout models:
3.3 Vout models:
Capacitive load
3.9 V
95 % rel H max.
Case material
copper, nickel plated
Baseplate material
non conductive FR4
Potting material
epoxy (UL 94V-0 - rated)
Weight
27 g (0.95 oz)
Soldering temperature
max. 265 °C / 10 sec.
APPLICATION NOTE
Requirement on output load
In order to ensure the product operate efficiently and reliably,in addition to a max load(namely full load), a minimum load is specified for this kind
of DC/DC converter.Make sure the specified range of input voltage is not exceeded,the minimum output load no less than 10% load.If the actual
load is less than the specified minimum load, the output ripple may increase sharply while its efficiency and reliability will reduce greatly.If the actual
output power is very small,please add an appropriate resistor as extra loading,or contact our company for other lower output power products.
Recommended Circuit
All the WRA_ZMD-20W&WRB_ZMD-20W Series have been tested according to the following recommended testing circuit before leaving
factory.This series should be tested under load(see Figure 1).
If you want to further decrease the input/output ripple,you can increase apacitance properly or choose capacitors with low ESR.However,the
capacitance of the output filter capacitor must be proper.If the capacitance is too big,a startup problem might arise.For every channel of
output,provided the safe and reliable operation is ensured,the greatest capacitance of its filter capacitor sees (Table 1).General:
Cin: 10μF-47μF
Cout: 10μF/100mA
CTRL Terminal
When open or high impedance,the converter work well; When this pin is ‘high’; the converter shutdown; It should be note that the input current
(Ic) should between 5-10mA, exceeding the maximum 20mA will cause permanence damage to the converter.
The value of R Can be derived as follows :
Input current
While using unstable power source,please ensure the output voltage and ripple voltage do not exceed indexes of the converter.The preceding
power source must be able to provide for converter sufficient starting current Ip(Figure 2).
General:Ip≤1.6*Iin-max
No parallel connection or plug and play
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 2 of 3
WRA-ZMD-20W&WRB-ZMD -20W Series
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
MECHANICAL DIMENSION
RECOMMENDED FOOTPRINT
Note:
Unit:mm[inch]
Pin section tolerances:±0.10mm[±0.004inch]
General tolerances:±0.25mm[±0.010inch]
RECOMMENDED FOOTPRINT
Top view,grid:2.54mm(0.1inch)
diameter:1.00mm(0.039inch)
FOOTPRINT DETAILS
Pin
Single
Dual
1
GND
GND
2
Vin
Vin
3
+Vo
+Vo
4
NC
0V
5
0V
-Vo
TUBE OUTLINE DIMENSIONS
NC:No connection
When the environment temperature is higher than 71℃, the
product output power should be less then 60% of the rated
power.
No parallel connection or plug and play.
Use dual output simultaneously,forbid pening output pin (0V)
to use as single output.
Note:
Unit :mm[inch]
General tolerances:±0.50mm[±0.020inch]
L=230mm[9.055inch] Tube Quantity: 7pcs
Note:
1. The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
2. Operation under 10% load will not damage the converter; However, they may not meet all specification listed.
3. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
4. In this datasheet, all the test methods of indications are based on corporate standards.
5. Only typical models listed, other models may be different, please contact our technical person for more details.
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646