MICRODC WRA-ZMD-20W

WRA-ZMD-20W&WRB-ZMD -20W Series
W, WIDE INPUT, ISOLATED & REGULATED DUAL/SINGLE OUTPUT DC
20
20W,
DC--DC CONVERTER
SELECTION GUIDE
Order code
Input voltage
range
Output voltage
Output
current max.
Efficiency typ.
WRB2403ZMD-5500
9 – 36 VDC
3.3 VDC
5500 mA
85 %
WRB2405ZMD-20W
9 – 36 VDC
5 VDC
4000 mA
88 %
WRB2412ZMD-20W
9 – 36 VDC
12 VDC
1670 mA
86 %
WRB2415ZMD-20W
9 – 36 VDC
15 VDC
1330 mA
86 %
WRA2405ZMD-20W
9 – 36 VDC
± 5 VDC
± 2000 mA
88 %
◆Ultra wide 4 : 1 input range
WRA2412ZMD-20W
9 – 36 VDC
± 12 VDC
± 835 mA
87 %
◆Extended operating temperature range
WRA2415ZMD-20W
9 – 36 VDC
± 15 VDC
± 665 mA
87 %
WRB4803ZMD-5500
18 – 75 VDC
3.3 VDC
5500 mA
85 %
WRB4805ZMD-20W
18 – 75 VDC
5 VDC
4000 mA
88 %
WRB4812ZMD-20W
18 – 75 VDC
12 VDC
1670 mA
87 %
WRB4815ZMD-20W
18 – 75 VDC
15VDC
1330 mA
87 %
◆I/O-isolation 1500 VDC
WRA4805ZMD-20W
18 – 75 VDC
± 5 VDC
± 2000 mA
89 %
◆Remote On/Off
WRA4812ZMD-20W
18 – 75 VDC
± 12 VDC
± 835 mA
88 %
WRA4815ZMD-20W
18 – 75 VDC
± 15 VDC
± 665 mA
88 %
FEATURES
◆High power density in 1" x 2" metal package
–40℃ to +85℃ max.
◆No minimum load required
◆Adjustable output voltage
◆Industry standard footprint
◆Shielded metal case with insulated baseplate
Input Specifications
◆Optional heatsink
Input current at no load
◆Lead free design - RoHS compliant
◆3-year product warranty
Input current at full load
MODEL SELECTION
①
②
③
④
⑤
⑥
⑦
WRB 24 12 Z M D -20W(1670)
24 Vin models:
50 mA typ.
48 Vin models:
35 mA typ.
24 Vin models:
1000 mA typ.
48 Vin models:
500 mA typ.
Surge voltage
24 Vin models:
50 V max.
(100 msec. max.)
48 Vin models:
100 V max.
5 V / ms, max.
Input voltage variation (dv/df)
①Product Series
②Input Voltage
③Output Voltage
④Wide (4:1) Input Range
⑤Metal Shield
⑥2" x 1"DIP Package Style
⑦Rated Power(Output current)
The WRA-ZMD-20W & WRB-ZMD-20W Series is a
family of high performance 20W DC/DC converter
modules featuring ultra wide 4:1 input voltage ranges in a
compact
2“x1“
low
profile
Start-up voltage / under voltage
24 Vin models:
9 VDC / 7.5 VDC typ.
lockout
48 Vin models:
18 VDC / 15 VDC typ.
EN 55022 level A, FCC part 15, level A with
Conducted noise(input)
APPLICATIONS
ultra
(complies to ETS 300 132 part. 4.4)
package
external capacitor (see application note)
ESD (input)
EN 61000-4-2, perf. criteria B
Fast transient (input)
EN 61000-4-4, perf. criteria B
Surge (input)
EN 61000-4-5, perf. criteria B
with
industry-standard footprint. A very high efficiency al-lows
an operating temperature range of –40°C to 85°C. Further
General Specifications
standard features include remote On/Off, output voltage
trimming,over
voltage
protection
and
short-circuit
protection.
Reliability, calculated MTBF
(MIL-HDBK-217F
ground benign)
>560000 h @ + 25 °C
Isolation voltage (60 sec.)
– Input/Output
1500 VDC
Isolation capacity
– Input/Output
1500 pF max
operated equipment and distributed power architectures
Isolation resistance
– Input/Output
>1000 M Ohm
in communication and industrial electronics, everywhere
Switching frequency (fixed)
where isolated, tightly regulated voltages are required.
Vibration
Typical applications for these converters are battery
Remote On/Off
Safety standards
400 kHz typ. (pulse width modulation PWM)
10-55Hz, 10G, 30 minutes along X,Y,Z
– On:
3.0 to 12 VDC or open circuit.
– Off:
0 to 1.2 VDC or short circuit pin 2 and pin 6
– Off idle current:
2.5 mA typ.
UL 60950
MICRODC reserves the copyright
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 1 of 3
WRA-ZMD-20W&WRB-ZMD -20W Series
Output Specifications
Voltage set accuracy
±1 %
Output voltage
±10 % by external resistor, see application note:
(single output models only)
adjustment
http://www.microdc.cn/uploadfiles/WRA-ZMD-20W&WRB-ZMD-20W.pdf
– Input variation Vin min. to Vin max.
0.2 % max.
– Load variation 0 – 100%:
Regulation
single output models:
dual output models:
– Load cross variation 25 % / 100 %
0.5 % max.
1 % max. (balanced load)
5 % max.
Temperature coefficient
0.02 % /K
(20 MHz Bandwidth)
Ripple and noise
single output models:
75 mVpk-pk max.
dual output models:
100 mVpk-pk max.
Start up time
(nominal Vin and constant resistive load)
20 ms typ.
Transient Response
(25% load step change)
20 ms typ.
Transient Response
(25% load step change)
250 µs typ.
Short circuit protection
indefinite (automatic recovery)
Over load protection
150% of Iout max typ.
3.3 Vout models:
5 /±5 Vout models:
Over voltage protection
15 / ±15 V
15 /±15 Vout models:
18 / ±18 V
5 Vout models / ± 5 Vout models:
18’000 µF max.
9600 µF max. / ± 4800 µF max.
12 Vout models / ±12 Vout models:
1600 µF max. / ± 800 µF max.
15 Vout models / ±15 Vout models:
1000 µF max. / ± 500 µF max.
General Specifications
Temperature ranges
6.2 / ±6.2 V
12 /±12 Vout models:
3.3 Vout models:
Capacitive load
3.9 V
Physical Specifications
– Operating
–40 °C to +85 °C
Case material
copper, nickel plated
– Case temperature
+105 °C max.
Baseplate material
non conductive FR4
– Storage
–55 °C to +125 °C
Potting material
epoxy (UL 94V-0 - rated)
95 % rel H max.
Weight
27 g (0.95 oz)
Soldering temperature
max. 265 °C / 10 sec.
Humidity (non condensing)
APPLICATION NOTE
Requirement on output load
In order to ensure the product operate efficiently and reliably,in addition to a max load(namely full load), a minimum load is specified for
this kind of DC/DC converter.Make sure the specified range of input voltage is not exceeded,the minimum output load no less than 10% load.If
the actual load is less than the specified minimum load, the output ripple may increase sharply while its efficiency and reliability will reduce
greatly.If the actual output power is very small,please add an appropriate resistor as extra loading,or contact our company for other lower
output power products.
Recommended Circuit
All the WRA_ZMD-20W&WRB_ZMD-20W Series have been tested according to the following recommended testing circuit before leaving
factory.This series should be tested under load(see Figure 1).
If you want to further decrease the input/output ripple,you can increase apacitance properly or choose capacitors with low ESR.However,the
capacitance of the output filter capacitor must be proper.If the capacitance is too big,a startup problem might arise.For every channel of
output,provided the safe and reliable operation is ensured,the greatest capacitance of its filter capacitor sees (Table 1).General:
Cin: 10μF-47μF
Cout: 10μF/100mA
CTRL Terminal
When open or high impedance,the converter work well; When this pin is ‘high’; the converter shutdown; It should be note that the input
current (Ic) should between 5-10mA, exceeding the maximum 20mA will cause permanence damage to the converter.
The value of R Can be derived as follows :
Input current
While using unstable power source,please ensure the output voltage and ripple voltage do not exceed indexes of the converter.The
preceding power source must be able to provide for converter sufficient starting current Ip(Figure 2).
General:Ip≤1.6*Iin-max
No parallel connection or plug and play
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 2 of 3
WRA-ZMD-20W&WRB-ZMD -20W Series
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT
Note:
Unit:mm[inch]
Pin section tolerances:±0.10mm[±0.004inch]
General tolerances:±0.25mm[±0.010inch]
FOOTPRINT DETAILS
Pin
Single
Dual
1
GND
GND
2
Vin
Vin
3
+Vo
+Vo
4
NC
0V
5
0V
-Vo
RECOMMENDED FOOTPRINT
TUBE OUTLINE DIMENSIONS
NC:No connection
When the environment temperature is higher than
71
71℃,, the product output power should be less
then 60% of the rated power.
Note:
Unit :mm[inch]
No parallel connection or plug and play.
General tolerances:±0.50mm[±0.020inch]
L=230mm[9.055inch] Tube Quantity: 7pcs
Use dual output simultaneously,forbid pening
output pin (0V) to use as single output.
Note:
1. The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
2. Operation under 10% load will not damage the converter; However, they may not meet all specification listed.
3. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise
specified.
4. In this datasheet, all the test methods of indications are based on corporate standards.
5. Only typical models listed, other models may be different, please contact our technical person for more details.
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 3 of 3