IRF HFA08TB120PBF

PD-95736
HFA08TB120PbF
HEXFRED
Ultrafast, Soft Recovery Diode
TM
•
•
•
•
•
•
VR = 1200V
BASE
CATHODE
Features
Ultrafast Recovery
Ultrasoft Recovery
Very Low IRRM
Very Low Qrr
Specified at Operating Conditions
Lead-Free
VF (typ.)* = 2.4V
4
IF (AV) = 8.0A
Qrr (typ.)= 140nC
IRRM (typ.) = 4.5A
2
1
CATHODE
trr (typ.) = 28ns
3
di(rec) M /dt (typ.)* = 85A /µs
ANODE
2
Benefits
• Reduced RFI and EMI
• Reduced Power Loss in Diode and Switching
Transistor
• Higher Frequency Operation
• Reduced Snubbing
• Reduced Parts Count
TO-220AC
Description
International Rectifier's HFA08TB120 is a state of the art ultra fast recovery diode.
Employing the latest in epitaxial construction and advanced processing techniques it
features a superb combination of characteristics which result in performance which is
unsurpassed by any rectifier previously available. With basic ratings of 1200 volts and
8 amps continuous current, the HFA08TB120 is especially well suited for use as the
companion diode for IGBTs and MOSFETs. In addition to ultra fast recovery time, the
HEXFRED product line features extremely low values of peak recovery current (IRRM) and
does not exhibit any tendency to "snap-off" during the tb portion of recovery. The
HEXFRED features combine to offer designers a rectifier with lower noise and significantly
lower switching losses in both the diode and the switching transistor. These HEXFRED
advantages can help to significantly reduce snubbing, component count and heatsink
sizes. The HEXFRED HFA08TB120 is ideally suited for applications in power supplies
and power conversion systems (such as inverters), motor drives, and many other similar
applications where high speed, high efficiency is needed.
Absolute Maximum Ratings
Parameter
VR
IF @ TC = 100°C
IFSM
IFRM
PD @ T C = 25°C
PD @ TC = 100°C
TJ
TSTG
Cathode-to-Anode Voltage
Continuous Forward Current
Single Pulse Forward Current
Maximum Repetitive Forward Current
Maximum Power Dissipation
Maximum Power Dissipation
Operating Junction and
Storage Temperature Range
Max
1200
8.0
130
32
73.5
29
- 55 to 150
Units
V
A
W
°C
* 125°C
www.irf.com
1
10/18/04
HFA08TB120PbF
Electrical Characteristics @ TJ = 25°C (unless otherwise specified)
VBR
Parameter
Min Typ Max Units
Test Conditions
Cathode Anode Breakdown
1200
-
-
V
IR = 100µA
-
2.6
3.3
V
IF = 8.0A
Voltage
VFM
Max. Forward Voltage
-
3.4
4.3
IF = 16A
-
2.4
3.1
IF = 8.0A, TJ = 125°C
Max. Reverse Leakage
-
0.31
10
Current
-
135 1000
CT
Junction Capacitance
-
11
20
pF
VR = 200V
LS
Series Inductance
-
8.0
-
nH
Measured lead to lead 5mm from pkg body
IRM
µA
VR = VR Rated
TJ = 125°C, VR = 0.8 x VR RatedD R
Rated
Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified)
Parameter
trr
Min Typ Max Units
-
28
-
trr1
-
63
95
TJ = 25°C
IF = 8.0A
trr2
-
106
160
TJ = 125°C
VR = 200V
-
4.5
8.0
TJ = 25°C
di f /dt = 200A/µs
-
6.2
11
-
140
380
Qrr2
-
335
880
di(rec)M /dt1 Peak Rate of Recovery
-
133
-
di(rec)M /dt2 Current During t b
-
85
-
IRRM1
Reverse Recovery Time
Peak Recovery Current
IRRM2
Qrr1
Reverse Recovery Charge
ns
Test Conditions
A
IF = 1.0A, dif/dt = 200A/µs, V R = 30V
TJ = 125°C
nC
TJ = 25°C
TJ = 125°C
A/µs
TJ = 25°C
TJ = 125°C
Thermal - Mechanical Characteristics
Parameter
Min
Typ
Max
Units
Tlead 
Lead Temperature
-
-
300
°C
RthJC
Thermal Resistance, Junction to Case
-
-
1.7
k/W
RthJA ‚
Thermal Resistance, Junction to Ambient
-
-
40
RthCSƒ
Thermal Resistance, Case to Heat Sink
-
0.25
-
Wt
Weight
-
6.0
-
Mounting Torque
g
-
0.21
-
(oz)
6.0
-
12
Kg-cm
5.0
-
10
lbf•in
 0.063 in. from Case (1.6mm) for 10 sec
‚ Typical Socket Mount
ƒ Mounting Surface, Flat, Smooth and Greased
2
www.irf.com
HFA08TB120PbF
1000
T = 150˚C
J
125˚C
100
100˚C
10
1
0.1
25˚C
0.01
0
300
600
900
1200
Reverse Voltage - VR (V)
Fig. 2 - Typ. Values Of Reverse Current
Vs. Reverse Voltage
10
100
Junction Capacitance - CT (pF)
Instantaneous Forward Current - I F (A)
Reverse Current - I R (µA)
100
T = 150˚C
J
T = 125˚C
J
T = 25˚C
J
1
0
2
4
6
8
T = 25˚C
J
10
1
10
1
10
100
1000
10000
Reverse Voltage - VR (V)
Fig. 3 - Typical Junction Capacitance
Vs. Reverse Voltage
Forward Voltage Drop - VFM (V)
Fig. 1 - Max. Forward Voltage Drop Characteristics
Thermal Impedance Z thJC (°C/W)
10
1
D = 0.50
D = 0.20
D = 0.10
D = 0.05
D = 0.02
D = 0.01
0.1
PDM
t1
Single Pulse
(Thermal Resistance)
t2
Notes:
1. Duty factor D = t1/ t 2
2. Peak Tj = Pdm x ZthJC + Tc
0.01
0.00001
0.0001
0.001
0.01
t1, Rectangular Pulse Duration (Seconds)
0.1
1
Fig. 4 - Max. Thermal Impedance Z thJC Characteristics
www.irf.com
3
HFA08TB120PbF
20
160
V R= 160V
T J = 125˚C
T J = 25˚C
IF = 8 A
IF = 4 A
140
16
IF = 8 A
IF = 4 A
12
100
Irr ( A)
trr ( ns )
120
80
8
60
4
40
VR = 160V
TJ = 125˚C
TJ = 25˚C
20
100
0
100
1000
1000
di F /dt (A/µs )
di F /dt (A/µs )
Fig. 5 - Typical Reverse Recovery
Vs. dif /dt
Fig. 6 - Typical Recovery Current
Vs. dif /dt
1200
1000
VR = 160V
TJ = 125˚C
TJ = 25˚C
1000
di (REC) M/dt (A/µs )
IF = 8 A
IF = 4 A
800
Qrr ( nC )
IF = 8 A
IF = 4 A
600
400
100
200
VR = 160V
TJ = 125˚C
TJ = 25˚C
0
100
1000
di F /dt (A/µs )
Fig. 8 - Typical Stored Charge vs. dif /dt
4
10
100
1000
di F /dt (A/µs )
Fig. 7 - Typical di (REC) M/dt vs. dif /dt
www.irf.com
HFA08TB120PbF
Reverse Recovery Circuit
VR = 200V
0.01 Ω
L = 70µH
D.U.T.
di
F /dt
dif/dt
ADJUST
D
IRFP250
G
S
Fig. 9- Reverse Recovery Parameter Test Circuit
3
t rr
IF
tb
ta
0
Q rr
2
I RRM
4
0.5 I RRM
di(rec)M/dt
5
0.75 I RRM
1
di
/dt
diFf /dt
1. diF /dt - Rate of change of current through zero
crossing
2. IRRM - Peak reverse recovery current
3. trr - Reverse recovery time measured from zero
crossing point of negative going IF to point where
a line passing through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current
4. Qrr - Area under curve defined by t rr
and IRRM
t rr x I RRM
Q rr =
2
5. di (rec) M / dt - Peak rate of change of
current during t b portion of t rr
Fig. 10 - Reverse Recovery Waveform and Definitions
www.irf.com
5
HFA08TB120PbF
TO-220AC Package Outline
Dimensions are shown in millimeters (inches)
TO-220AC Part Marking Information
PART NUMBER
EXAMPLE: T HIS IS A HFA06T B120
LOT CODE 1789
ASS EMBLED ON WW 19, 2001
IN THE ASSEMBLY LINE "C"
INTERNATIONAL
RECT IFIER
LOGO
DAT E CODE
ASS EMBLY
LOT CODE
P = LEAD-FREE
YEAR 1 = 2001
WEEK 19
LINE C
PART NUMBER
EXAMPLE: T HIS IS A HFA06T B120
LOT CODE 1789
ASS EMBLED ON WW 19, 2001
IN THE ASS EMBLY LINE "C"
6
INT ERNATIONAL
RECT IFIER
LOGO
DAT E CODE
AS SEMBLY
LOT CODE
YEAR 1 = 2001
WEEK 19
P = LEAD-FREE
www.irf.com
HFA08TB120PbF
Ordering Information Table
HF
A
08
TB 120
Device Code
HF
A
HF
1
08
A
08
2
1
-
Hexfred Family
2
-
Process Designator
TB
TB
3
120
120
4
A
= subs. elec. irrad.
B
= subs. Platinum
3
-
Current Rating
(08 = 8A)
4
-
Package Outline
(TB = TO-220, 2 Leads)
5
-
Voltage Rating
(120 = 1200V)
5
Note:"PbF" suffix at the end of the part number
indicates Lead-Free.
Data and specifications subject to change without notice.
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7903
Visit us at www.irf.com for sales contact information.10/04
www.irf.com
7