INFINEON BTS550P

PROFET® Data Sheet BTS550P
Smart Highside High Current Power Switch
Product Summary
Overvoltage protection
Output clamp
Operating voltage
On-state resistance
Load current (ISO)
Short circuit current limitation
Current sense ratio
Reversave
• Reverse battery protection by self turn on of
power MOSFET
Features
• Overload protection
• Current limitation
• Short circuit protection
• Overtemperature protection
• Overvoltage protection (including load dump)
• Clamp of negative voltage at output
• Fast deenergizing of inductive loads 1)
• Low ohmic inverse current operation
• Diagnostic feedback with load current sense
• Open load detection via current sense
• Loss of Vbb protection2)
• Electrostatic discharge (ESD) protection
Vbb(AZ)
62
VON(CL)
44
Vbb(on) 5.0 ... 34
RON
IL(ISO)
IL(SC)
IL : IIS
V
V
V
3.6 mΩ
115
A
220
A
21000
TO-218AB/5
5
Application
• Power switch with current sense diagnostic
feedback for 12 V and 24 V DC grounded loads
• Most suitable for loads with high inrush current
like lamps and motors; all types of resistive and
inductive loads
• Replaces electromechanical relays, fuses and discrete circuits
1
Straight leads
General Description
N channel vertical power FET with charge pump, current controlled input and diagnostic feedback with load

current sense, integrated in Smart SIPMOS chip on chip technology. Providing embedded protective functions.
3 & Tab
Voltage
source
Voltage
sensor
Overvoltage
Current
Gate
protection
limit
protection
Limit for
unclamped
ind. loads
Charge pump
Level shifter
Rectifier
2
IN
Output
Voltage
detection
Logic
ESD
I IN
+ V bb
R bb
OUT
1, 5
IL
Current
Sense
Load
Temperature
sensor
IS

PROFET
I IS
Load GND
4
VIN
V IS
R
IS
Logic GND
1)
2)
With additional external diode.
Additional external diode required for energized inductive loads (see page 9).
Infineon Technologies AG
1 of 15
2003-Oct-01
Data Sheet BTS550P
Pin
Symbol
Function
1
OUT
O
Output to the load. The pins 1 and 5 must be shorted with each other
especially in high current applications!3)
2
IN
I
Input, activates the power switch in case of short to ground
3
Vbb
+
Positive power supply voltage, the tab is electrically connected to this pin.
In high current applications the tab should be used for the Vbb connection
instead of this pin4).
4
IS
S
Diagnostic feedback providing a sense current proportional to the load
current; zero current on failure (see Truth Table on page 7)
5
OUT
O
Output to the load. The pins 1 and 5 must be shorted with each other
especially in high current applications!3)
Maximum Ratings at Tj = 25 °C unless otherwise specified
Parameter
Supply voltage (overvoltage protection see page 4)
Supply voltage for short circuit protection,
Tj,start =-40 ...+150°C: (EAS limitation see diagram on page 9)
Load current (short circuit current, see page 5)
Load dump protection VLoadDump = UA + Vs, UA = 13.5 V
RI5) = 2 Ω, RL = 0.54 Ω, td = 200 ms,
IN, IS = open or grounded
Operating temperature range
Storage temperature range
Power dissipation (DC), TC ≤ 25 °C
Inductive load switch-off energy dissipation, single pulse
Vbb = 12V, Tj,start = 150°C, TC = 150°C const.,
IL = 20 A, ZL = 15 mH, 0 Ω, see diagrams on page 10
Electrostatic discharge capability (ESD)
Symbol
Vbb
Vbb
Values
40
34
Unit
V
V
self-limited
A
80
V
Tj
Tstg
Ptot
-40 ...+150
-55 ...+150
360
°C
EAS
3
J
VESD
4
kV
+15 , -250
+15 , -250
mA
IL
VLoad dump6)
W
Human Body Model acc. MIL-STD883D, method 3015.7 and ESD
assn. std. S5.1-1993, C = 100 pF, R = 1.5 kΩ
Current through input pin (DC)
Current through current sense status pin (DC)
IIN
IIS
see internal circuit diagrams on page 8
3)
4)
5)
6)
Not shorting all outputs will considerably increase the on-state resistance, reduce the peak current capability
and decrease the current sense accuracy
Otherwise add up to 0.5 mΩ (depending on used length of the pin) to the RON if the pin is used instead of the
tab.
RI = internal resistance of the load dump test pulse generator.
VLoad dump is setup without the DUT connected to the generator per ISO 7637-1 and DIN 40839.
Infineon Technologies AG
2
2003-Oct-01
Data Sheet BTS550P
Thermal Characteristics
Parameter and Conditions
Thermal resistance
Symbol
chip - case: RthJC7)
Junction - ambient (free air): RthJA
min
---
Values
typ
max
-- 0.35
30
--
Unit
K/W
Electrical Characteristics
Parameter and Conditions
Symbol
at Tj = -40 ... +150 °C, Vbb = 12 V unless otherwise specified
Load Switching Capabilities and Characteristics
On-state resistance (Tab to pins 1,5, see measurement
circuit page 8)
IL = 20 A, Tj = 25 °C: RON
VIN = 0, IL = 20 A, Tj = 150 °C:
IL = 120 A, Tj = 150 °C:
Vbb
IL = 20 A, Tj = 150 °C: RON(Static)
9
)
Nominal load current (Tab to pins 1,5)
IL(ISO)
10
)
ISO 10483-1/6.7: VON = 0.5 V, Tc = 85 °C
Maximum load current in resistive range
(Tab to pins 1,5)
VON = 1.8 V, Tc = 25 °C: IL(Max)
see diagram on page 12
VON = 1.8 V, Tc = 150 °C:
11
)
Turn-on time
IIN
to 90% VOUT: ton
Turn-off time
IIN
to 10% VOUT: toff
RL = 1 Ω , Tj =-40...+150°C
Slew rate on 11) (10 to 30% VOUT )
dV/dton
RL = 1 Ω ,Tj =25°C
Slew rate off 11) (70 to 40% VOUT )
-dV/dtoff
RL = 1 Ω ,Tj =25°C
= 6V8),
Values
min
typ
max
--
Unit
-90
2.8
5.0
-7
115
3.6
6.5
6.5
10
--
390
215
120
40
--250
90
--600
150
0.2
0.5
0.8
V/µs
0.2
0.6
1
V/µs
mΩ
A
A
µs
7)
Thermal resistance RthCH case to heatsink (about 0.25 K/W with silicone paste) not included!
Decrease of Vbb below 10 V causes a slowly a dynamic increase of RON to a higher value of RON(Static). As
long as VbIN > VbIN(u) max, RON increase is less than 10 % per second for TJ < 85 °C.
9) not subject to production test, specified by design
10) T is about 105°C under these conditions.
J
11) See timing diagram on page 13.
8)
Infineon Technologies AG
3
2003-Oct-01
Data Sheet BTS550P
Parameter and Conditions
Symbol
at Tj = -40 ... +150 °C, Vbb = 12 V unless otherwise specified
Inverse Load Current Operation
On-state resistance (Pins 1,5 to pin 3)
VbIN = 12 V, IL = - 20 A
Tj = 25 °C: RON(inv)
see diagram on page 10
Tj = 150 °C:
Nominal inverse load current (Pins 1,5 to Tab)
IL(inv)
10
VON = -0.5 V, Tc = 85 °C
-VON
Drain-source diode voltage (Vout > Vbb)
IL = - 20 A, IIN = 0, Tj = +150°C
Values
min
typ
max
--
Unit
3.6
6.5
--
mΩ
90
2.8
5.0
115
--
0.6
0.7
V
Vbb(on)
VbIN(u)
5.0
1.5
-3.0
34
4.5
V
V
VbIN(ucp)
VbIN(Z)
3.0
60
62
---
4.5
-64
15
25
6.0
--25
50
V
V
A
Operating Parameters
Operating voltage (VIN = 0) 8, 12)
Undervoltage shutdown 13)
Undervoltage start of charge pump
see diagram page 14
Overvoltage protection14)
Tj =-40°C:
Ibb = 15 mA
Tj = 25...+150°C:
Standby current
Tj =-40...+25°C:
IIN = 0
Tj = 150°C:
Ibb(off)
µA
12)
If the device is turned on before a Vbb-decrease, the operating voltage range is extended down to VbIN(u).
For the voltage range 0..34 V the device is fully protected against overtemperature and short circuit.
13) V
bIN = Vbb - VIN see diagram on page 8. When VbIN increases from less than VbIN(u) up to VbIN(ucp) = 5 V
(typ.) the charge pump is not active and VOUT ≈Vbb - 3 V.
14) See also VON(CL) in circuit diagram on page 9.
Infineon Technologies AG
4
2003-Oct-01
Data Sheet BTS550P
Parameter and Conditions
Symbol
at Tj = -40 ... +150 °C, Vbb = 12 V unless otherwise specified
Protection Functions15)
Short circuit current limit (Tab to pins 1,5)16
VON = 12 V, time until shutdown max. 350 µs Tc =-40°C: IL(SCp)
Tc =25°C:
Tc =+150°C:
Short circuit shutdown delay after input current
positive slope, VON > VON(SC)
td(SC)
min. value valid only if input "off-signal" time exceeds 30 µs
Output clamp 17)
IL= 40 mA: -VOUT(CL)
(inductive load switch off)
Output clamp (inductive load switch off)
at VOUT = Vbb - VON(CL) (e.g. overvoltage)
VON(CL)
IL= 40 mA
Short circuit shutdown detection voltage
(pin 3 to pins 1,5)
VON(SC)
Thermal overload trip temperature
Tjt
Thermal hysteresis
∆Tjt
Reverse Battery
Reverse battery voltage 18)
-Vbb
On-state resistance (Pins 1,5 to pin 3)
Tj = 25 °C: RON(rev)
Vbb = -12V, VIN = 0, IL = - 20 A, RIS = 1 kΩ Tj = 150 °C:
Integrated resistor in Vbb line
Tj=25°C:
Tj=150°C:
Rbb
Values
min
typ
max
Unit
100
110
120
190
220
210
350
330
310
A
80
--
350
µs
14
17
20
V
40
44
47
V
-150
--
6
-10
----
V
°C
K
--
--
32
V
--
3.4
--
4.3
7.5
mΩ
90
110
135
Ω
105
125
150
15)
Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as “outside” normal operating range. Protection functions are not
designed for continuous repetitive operation.
16 ) Short circuit is a failure mode. The device is not designed to operate continuously into a short circuit by
permanent resetting the short circuit latch function. The lifetime will be reduced under such conditions.
17) This output clamp can be "switched off" by using an additional diode at the IS-Pin (see page 8). If the diode
is used, VOUT is clamped to Vbb- VON(CL) at inductive load switch off.
18) The reverse load current through the intrinsic drain-source diode has to be limited by the connected load (as
it is done with all polarity symmetric loads). Note that under off-conditions (IIN = IIS = 0) the power transistor
is not activated. This results in raised power dissipation due to the higher voltage drop across the intrinsic
drain-source diode. The temperature protection is not active during reverse current operation! Increasing
reverse battery voltage capability is simply possible as described on page 9.
Infineon Technologies AG
5
2003-Oct-01
Data Sheet BTS550P
Parameter and Conditions
Symbol
at Tj = -40 ... +150 °C, Vbb = 12 V unless otherwise specified
Diagnostic Characteristics
Current sense ratio,
IL = 120 A,Tj =-40°C: kILIS
static on-condition,
Tj =25°C:
kILIS = IL : IIS,
Tj =150°C:
VON < 1.5 V19),
IL = 20 A,Tj =-40°C:
VIS <VOUT - 5 v,
Tj =25°C:
VbIN > 4.0 V
Tj =150°C:
see diagram on page 11
IL = 12 A,Tj =-40°C:
Tj =25°C:
Tj =150°C:
IL = 6 A,Tj =-40°C:
Tj =25°C:
Tj =150°C:
IIS=0 by IIN =0 (e.g. during deenergizing of inductive loads):
Values
min
typ
max
Unit
19 000
19 000
18 000
18 500
18 500
18 000
16 000
17 000
17 500
12 000
14 000
16 000
20 600
20 500
19 000
22 300
21 400
19 500
23 500
22 000
19 900
28 000
24 000
20 500
23 000
22 500
21 500
26 000
25 000
23 000
30 000
26 500
24 500
46 000
34 000
30 000
IIS,lim
6.5
--
--
mA
IIN = 0: IIS(LL)
--
--
0.5
µA
--
2
--
-60
62
--64
500
---
µs
V
--
0.8
1.5
mA
--
--
80
µA
Sense current saturation
Current sense leakage current
Current sense settling time20)
Overvoltage protection
Ibb = 15 mA
VIN = 0, IL ≤ 0: IIS(LH)
ts(IS)
Tj =-40°C: VbIS(Z)
Tj = 25...+150°C:
Input
Input and operating current (see diagram page 12) IIN(on)
IN grounded (VIN = 0)
Input current for turn-off21)
IIN(off)
19)
If VON is higher, the sense current is no longer proportional to the load current due to sense current
saturation, see IIS,lim .
20) not subject to production test, specified by design
21) We recommend the resistance between IN and GND to be less than 0.5 kΩ for turn-on and more than
500kΩ for turn-off. Consider that when the device is switched off (IIN = 0) the voltage between IN and GND
reaches almost Vbb.
Infineon Technologies AG
6
2003-Oct-01
Data Sheet BTS550P
Truth Table
Remark
Input
current
Output
Current
Sense
level
level
L
H
L
H
IIS
0
nominal
H
H
IIS, lim
H
H
0
L
H
L
H
L
H
L
H
L
L
L
L
L
H
H
Z23)
H
L
0
0
0
0
0
<nominal 22)
0
0
0
L
H
H
H
0
0
Normal
operation
Very high
load current
Currentlimitation
Short circuit to
GND
Overtemperature
Short circuit to
Vbb
Open load
Negative output
voltage clamp
Inverse load
current
=IL / kilis, up to IIS=IIS,lim
up to VON=VON(Fold back)
IIS no longer proportional to IL
VON > VON(Fold back)
if VON>VON(SC), shutdown will occure
L = "Low" Level
H = "High" Level
Options Overview
Type
BTS
6510P 550P
555
650P
Overtemperature protection with hysteresis
Tj >150 °C, latch function24)
Tj >150 °C, with auto-restart on cooling
Short circuit to GND protection
X
with overtemperature shutdown
X
X
X
X
X
switches off when VON>6 V typ.
(when first turned on after approx. 180 µs)
Overvoltage shutdown
-
X
X
X
-
-
Output negative voltage transient limit
to Vbb - VON(CL)
X
X
X
to VOUT = -19 V typ
X25)
X25)
X25)
Overtemperature reset by cooling: Tj < Tjt (see diagram on page 14)
Short circuit to GND: Shutdown remains latched until next reset via input (see diagram on page 13)
22)
Low ohmic short to Vbb may reduce the output current IL and can thus be detected via the sense current IIS.
Power Transistor "OFF", potential defined by external impedance.
24) Latch except when V -V
bb
OUT < VON(SC) after shutdown. In most cases VOUT = 0 V after shutdown (VOUT ≠
0 V only if forced externally). So the device remains latched unless Vbb < VON(SC) (see page 5). No latch
between turn on and td(SC).
25) Can be "switched off" by using a diode D (see page 8) or leaving open the current sense output.
S
23)
Infineon Technologies AG
7
2003-Oct-01
Data Sheet BTS550P
Terms
Current sense status output
I bb
Vbb
3
VbIN
VON
Vbb
R bb
V
IL
V
2
bb
IN
RIN
V
IN
I IN
OUT
PROFET
Z,IS
ZD
IS
1,5
IIS
IS
VbIS
R
4
I IS
DS
VIS
V OUT
R IS
Two or more devices can easily be connected in
parallel to increase load current capability.
RON measurement layout
≤ 5.5 mm
VIS
IS
VZ,IS = 64 V (typ.), RIS = 1 kΩ nominal (or 1 kΩ /n, if
n devices are connected in parallel). IS = IL/kilis can
be driven only by the internal circuit as long as Vout VIS > 5 V. If you want to measure load currents up
Vbb - 5 V
.
to IL(M), RIS should be less than
IL(M) / Kilis
Note: For large values of RIS the voltage VIS can
reach almost Vbb. See also overvoltage protection.
If you don't use the current sense output in your
application, you can leave it open.
Short circuit detection
Fault Condition: VON > VON(SC) (6 V typ.) and t> td(SC)
(80 ...350 µs).
+ Vbb
Vbb force contacts
Out Force Sense
contacts
contacts
(both out
pins parallel)
VON
OUT
Input circuit (ESD protection)
Logic
unit
V bb
ZD
V
Short circuit
detection
Inductive and overvoltage output clamp
R bb
+ Vbb
Z,IN
V bIN
VZ1
IN
I
VON
IN
VZG
OUT
PROFET
V IN
DS
When the device is switched off (IIN = 0) the
voltage between IN and GND reaches almost Vbb.
Use a mechanical switch, a bipolar or MOS
transistor with appropriate breakdown voltage as
driver. VZ,IN = 64 V (typ).
Infineon Technologies AG
IS
VOUT
VON is clamped to VON(Cl) = 42 V typ. At inductive
load switch-off without DS, VOUT is clamped to
8
2003-Oct-01
Data Sheet BTS550P
VOUT(CL) = -19 V typ. via VZG. With DS, VOUT is
clamped to Vbb - VON(CL) via VZ1. Using DS gives
faster deenergizing of the inductive load, but higher
peak power dissipation in the PROFET. In case of a
floating ground with a potential higher than 19V
referring to the OUT – potential the device will
switch on, if diode DS is not used.
Vbb disconnect with energized
inductive load
Provide a current path with load current capability
by using a diode, a Z-diode, or a varistor. (VZL < 72
V or VZb < 30 V if RIN=0). For higher clamp voltages
currents at IN and IS have to be limited to 250 mA.
Version a:
Overvoltage protection of logic part
V
+ Vbb
V
R IN
R bb
Z,IN V Z,IS
IN
bb
V
IN
bb
OUT
PROFET
IS
Logic
V OUT
PROFET
IS
R IS
V ZL
V Z,VIS
RV
Version b:
Signal GND
Rbb = 120 Ω typ., VZ,IN = VZ,IS = 64 V typ., RIS = 1 kΩ
nominal. Note that when overvoltage exceeds 69 V
typ. a voltage above 5V can occur between IS and
GND, if RV, VZ,VIS are not used.
V
Vbb
bb
IN
OUT
PROFET
Reverse battery protection
IS
- Vbb
R bb
V Zb
IN
OUT
R IN
Note that there is no reverse battery protection
when using a diode without additional Z-diode VZL,
VZb.
Power
Transistor
Logic
Version c: Sometimes a neccessary voltage clamp
is given by non inductive loads RL connected to the
same switch and eliminates the need of clamping
circuit:
IS
DS
D
R IS
RL
RV
Signal GND
Power GND
RV ≥ 1 kΩ, RIS = 1 kΩ nominal. Add RIN for reverse
battery protection in applications with Vbb above
1
1
1
+
+
=
16 V18); recommended value:
RIN RIS RV
0.1A
1
0.1A
if DS is not used (or
=
if
|Vbb| - 12V
RIN |Vbb| - 12V
DS is used).
To minimize power dissipation at reverse battery
operation, the summarized current into the IN and
IS pin should be about 120mA. The current can be
provided by using a small signal diode D in parallel
to the input switch, by using a MOSFET input switch
or by proper adjusting the current through RIS and
RV .
Infineon Technologies AG
V
Vbb
bb
IN
PROFET
RL
OUT
IS
9
2003-Oct-01
Data Sheet BTS550P
Inverse load current operation
Maximum allowable load inductance for
a single switch off
L = f (IL ); Tj,start = 150°C, Vbb = 12 V, RL = 0 Ω
Vbb
V bb
L [µH]
- IL
IN
+
OUT
PROFET
100000
V OUT +
IS
-
IIS
V IN
V IS
10000
-
R IS
1000
The device is specified for inverse load current
operation (VOUT > Vbb > 0V). The current sense
feature is not available during this kind of operation
(IIS = 0). With IIN = 0 (e.g. input open) only the intrinsic drain source diode is conducting resulting in
considerably increased power dissipation. If the
device is switched on (VIN = 0), this power
dissipation is decreased to the much lower value
RON(INV) * I2 (specifications see page 4).
Note: Temperature protection during inverse load
current operation is not possible!
100
10
1
1
10
100
1000
IL [A]
Externally adjustable current limit
Inductive load switch-off energy
dissipation
E bb
E AS
V
ELoad
bb
i L(t)
V bb
IN
OUT
PROFET
IS
I
IN
ZL
RIS
{
L
RL
EL
If the device is conducting, the sense current can be
used to reduce the short circuit current and allow
higher lead inductance (see diagram above). The
device will be turned off, if the threshold voltage of
T2 is reached by IS*RIS . After a delay time defined
by RV*CV T1 will be reset. The device is turned on
again, the short circuit current is defined by IL(SC)
and the device is shut down after td(SC) with latch
function.
Vbb
ER
V bb
Energy stored in load inductance:
EL =
IN
Rload
IN
Signal
EAS= Ebb + EL - ER= VON(CL)·iL(t) dt,
Infineon Technologies AG
ln (1+ |V
IL·RL
OUT(CL)|
T1
Signal
GND
with an approximate solution for RL > 0 Ω:
IL· L
(V + |VOUT(CL)|)
2·RL bb
OUT
IS
RV
While demagnetizing load inductance, the energy
dissipated in PROFET is
EAS=
PROFET
1/ ·L·I 2
2
L
CV
T2
R IS
Power
GND
)
10
2003-Oct-01
Data Sheet BTS550P
Characteristics
Current sense ratio:
KILIS = f(IL), TJ = 25 °C
kilis
Current sense versus load current:
IIS = f(IL)
IIS [mA]
34000
7
32000
6
30000
5
28000
max
4
26000
3
24000
max
22000
min
typ
2
20000
1
18000
min
0
16000
0
20
40
60
80
100
120
0
20
40
60
80
100
IL [A]
Current sense ratio:
KILIS = f(IL), TJ = -40 °C
Kilis
120
IL [A]
Current sense ratio:
KILIS = f(IL), TJ = 150 °C
Kilis
30000
46000
44000
42000
28000
40000
38000
26000
36000
34000
32000
24000
30000
max
28000
22000
max
26000
24000
22000
typ
20000
18000
min
16000
typ
20000
18000
14000
12000
min
16000
0
20
40
60
80
100
120
0
IL [A]
Infineon Technologies AG
11
20
40
60
80
100
120
IL [A]
2003-Oct-01
Data Sheet BTS550P
Typ. current limitation characteristic
IL = f (VON, Tj )
Typ. input current
IIN = f (VbIN), VbIN = Vbb - VIN
IL [A]
1.6
1.4
800
1.2
700
1.0
600
VON > V ON(SC) only for t < t d(SC)
(otherwise immediate shutdown)
500
0.8
400
0.6
300
TJ = 25°C
0.4
200
TJ = -40°C
100
0.2
TJ = 150°C
0
0
0
VON(FB)
5
10
15
0
20
20
40
60
80
VON [V]
In case of VON > VON(SC) (typ. 6 V) the device will be
switched off by internal short circuit detection.
IIN [mA]
VbIN [V]
Typ. on-state resistance
RON = f (Vbb, Tj ); IL = 20 A; VIN = 0
RON [mOhm]
10
9
8
static
dynamic
7
6
Tj = 150°C
5
85°C
4
3
25°C
2
-40°C
1
0
0
5
10
15
20
40
Vbb [V]
Infineon Technologies AG
12
2003-Oct-01
Data Sheet BTS550P
Timing diagrams
Figure 1a: Switching a resistive load,
change of load current in on-condition:
Figure 2b: Switching an inductive load:
IIN
IIN
VOUT
90%
dV/dtoff
VOUT
t on
dV/dton
t off
10%
IL
tslc(IS)
Load 1
IIS
t slc(IS)
IL
Load 2
IIS
tson(IS)
t
t
t soff(IS)
The sense signal is not valid during a settling time
after turn-on/off and after change of load current.
Figure 3a: Short circuit:
shut down by short circuit detection, reset by IIN = 0.
Figure 2a: Switching motors and lamps:
IIN
IIN
IL
IL(SCp)
VOUT
td(SC)
IIL
IIS
VOUT>>0
VOUT=0
IIS
t
t
Shut down remains latched until next reset via input.
Sense current saturation can occur at very high
inrush currents (see IIS,lim on page 6).
Infineon Technologies AG
13
2003-Oct-01
Data Sheet BTS550P
Figure 4a: Overtemperature
Reset if Tj<Tjt
IIN
IIS
Auto Restart
VOUT
Tj
t
Figure 6a: Undervoltage restart of charge pump,
overvoltage clamp
VOUT
V ON(CL)
VIN = 0
dynamic, short
Undervoltage
not below
VbIN(u)
6
4
IIN = 0
2
VON(CL)
0
0
V bIN(u)
4
V bIN(ucp)
Infineon Technologies AG
V bb
14
2003-Oct-01
Data Sheet BTS550P
Published by
Infineon Technologies AG,
St.-Martin-Strasse 53,
D-81669 München
© Infineon Technologies AG 2001
All Rights Reserved.
Package and Ordering Code
All dimensions in mm
TO-218AB/5 Option E3146 Ordering code
E3146
Q67060-S6952A3
Attention please!
The information herein is given to describe certain
components and shall not be considered as a guarantee of
characteristics.
Terms of delivery and rights to technical change reserved.
We hereby disclaim any and all warranties, including but not
limited to warranties of non-infringement, regarding circuits,
descriptions and charts stated herein.
Infineon Technologies is an approved CECC manufacturer.
Information
For further information on technology, delivery terms and
conditions and prices please contact your nearest Infineon
Technologies Office in Germany or our Infineon
Technologies Representatives worldwide (see address list).
Warnings
Due to technical requirements components may contain
dangerous substances. For information on the types in
question please contact your nearest Infineon Technologies
Office.
Infineon Technologies Components may only be used in lifesupport devices or systems with the express written
approval of Infineon Technologies, if a failure of such
components can reasonably be expected to cause the
failure of that life-support device or system, or to affect the
safety or effectiveness of that device or system. Life support
devices or systems are intended to be implanted in the
human body, or to support and/or maintain and sustain
and/or protect human life. If they fail, it is reasonable to
assume that the health of the user or other persons may be
endangered.
Infineon Technologies AG
15
2003-Oct-01