SPEC NO. 05-08-5016 REV 0 A B C D E F REV. P RH1021-5, PRECISION 5V REFERENCE REVISION RECORD DESCRIPTION INITIAL RELEASE • PAGE 2, ADDED PARAGRAPHS 3.2.1, 3.2.2, AND 3.2.3. PARAGRAPH 3.3b, ADDED “(SEE PARAGRAPH 3.2)”. • PAGE 4, PARAGRAPH 3.12, WAFER LOT ACCEPTANCE REDEFINED. PARAGRAPH 4.4.2, GROUP B INSPECTION, REDEFINED. PARAGRAPH 4.4.3, GROUP D INSPECTION, REDEFINED. • PAGE 5, PARAGRAPH 4.5, SOURCE INSPECTION, REDEFINED. • PAGE 6, FIGURE 1, TO5 CASE OUTLINE, ADDED θja AND θjc. • PAGE 4, AMENDED PARAGRAPHS 4.1 AND 4.1.1 TAKING EXCEPTION TO ANALYSIS OF CATASTROPHIC FAILURES. • PAGE 6, FIGURE 1, CHANGED θja FROM 180°C/W TO 150°C/W. • PAGE 2, PARAGRAPHS 3.2.1, 3.2.2, 3.2.3 HAD FIGURES 1, 2, AND 3 REMOVED. • PAGE 3, PARAGRAPH 3.7, CHANGED VERBIAGE FROM “SPECIFIED IN TABLE III TO “AND AS SPECIFIED IN TABLE III HEREIN”, LINE 2. PARAGRAPH 3.9, ADDED “HEREIN” AFTER “TABLE III”, LINE 2. • PAGE 4, PARAGRAPH 4.3, ADDED “HEREIN” AFTER “TABLE III”, LINE 2. PARAGRAPH 4.4.1, ADDED “HEREIN” AFTER “TABLE III”, LINE 2. PARAGRAPH 4.4.2.2, CHANGED VERBIAGE IN LINE 1 FROM “ALL FOOTNOTES OF TABLE IIA OF MIL-STD-883” TO “ALL FOOTNOTES PERTAINING TO TABLE IIA OF MIL-STD-883”. PARAGRAPH 4.4.3.2, CHANGED VERBIAGE IN LINE 1 FROM “ALL FOOTNOTES OF TABLE IV OF MIL-STD-883” TO “ALL FOOTNOTES PERTAINING TO TABLE IV IN MIL-STD-883.” • PAGE 3, PARAGRAPH 3.2.4, ADDED NEW DEVICE OPTION 4 (W10 FLATPACK). • PAGE 4, PARAGRAPH 3.8 CHANGED VERBIAGE ADDED FIGURES 5 AND 6. PARAGRAPH 3.10.1, ADDED FIGURE 2, PARAGRAPH 3.10.2, CHANGED VERBIAGE ADDED FIGURES 3 AND 4. PARAGRAPH 3.10.3, CHANGED VERBIAGE. PARAGRAPH 3.11.3, CHANGED FIGURE 4 TO 7. • PAGE 8, ADDED PAGE 7 DEVICE OPTION 4, PACKAGE OUTLINE. • PAGE 9, CHANGED FIGURE 2 TO 3. • PAGE 10, ADDED DEVICE OPTION 4, FIGURE 4 TERMINAL CONNECTIONS. • PAGE 11, CHANGED FIGURE 3 TO 5. • PAGE 12, ADDED DEVICE OPTION 4, FIGURE 6 BURN-IN CIRCUIT. • PAGE 13, CHANGED FIGURE 4 TO 7. • PAGE 15, CHANGED Vout OUTPUT VOLTAGE 10 krad (SI) MIN TO 9.992 AND MAX TO 10.008 AND ADDED VERBIAGE TO NOTE 3. • PAGE 8, CHANGED θja FROM +225°C/W TO +170°C/W AND θjc FROM +40°C/W TO 18°C/W PER PACKAGE ENGINEERING. DATE 06/12/96 11/25/97 04/8/98 09/28/99 11/18/99 06/23/00 9/06/00 REVISION RECORD AND DESCRIPTION CONTINUED ON NEXT PAGE. REVISION INDEX REVISION INDEX PAGE NO. REVISION PAGE NO. REVISION CAUTION: ELECTROSTATIC DISCHARGE SENSITIVE PART 1 2 3 4 5 6 7 8 9 10 11 12 P P P P P P P P P P P P ORIG DSGN ENGR MFG CM QA PROG 14 P LINEAR TECHNOLOGY CORPORATION MILPITAS, CALIFORNIA TITLE: MICROCIRCUIT, LINEAR, RH1021-5, PRECISION 5V REFERENCE SIZE FUNCT APPLICATION 13 P SIGNOFFS DATE CAGE CODE 94155 CONTRACT: DRAWING NUMBER 05-08-5016 REV P FOR OFFICIAL USE ONLY LINEAR TECHNOLOGY CORPORATIION PDF created with pdfFactory trial version www.pdffactory.com PAGE 1 OF 14 SPEC NO. 05-08-5016 REV G H REV. P RH1021-5, PRECISION 5V REFERENCE REVISION RECORD DESCRIPTION • CONVERSION FROM WORD PERFECT TO MICROSOFT WORD. REDUCED SPEC PAGES TO 14 TOTAL. • PAGE 2, AN ADDITIONAL REVISION RECORD PAGE WAS INSTALLED. • ACKNOWLEDGE THAT CHANGE IN REVISION E, PAGE 15, IS INCORRECT AND HAS BEEN REMOVED. • PAGE 3: PARAGRAPH 3.2.1 THROUGH 3.2.4, ADDED THE WORD “OPTION” PRECEDING THE NUMBER OF EACH LTC PART NUMBER FOR BETTER CUSTOMER ORDERING CONVENIENCE. • PAGE 4: PARAGRAPH 3.6, CHANGED “TABLE IA” TO “TABLE II” PARAGRAPH 3.7, CHANGED “TABLE III” TO “TABLE IV” PARAGRAPHS 3.8.1 AND 3.8.2, ADDED THE PACKAGE TYPES AND OPTIONS AFTER EACH FIGURE. PARAGRAPH 3.9, CHANGED “TABLE II” TO “TABLE III” PARAGRAPHS 3.10.1 AND 3.10.2, ADDED THE PACKAGE TYPES AFTER EACH FIGURE PARAGRAPH 3.11.1 WAS CHANGED FROM “…dosage rate of approximately 20 Rads per second” TO “…dosage rate of less than or equal to 10 Rads per second” • PAGE 5: PARAGRAPHS 4.1 THROUGH 4.4.2.1 CHANGES WERE DONE TO CLARIFY GROUP SAMPLING. • PAGE 6: PARAGRAPH 4.4.3 CHANGE WAS DONE TO CLARIFY GROUP SAMPLING. PARAGRAPHS 4.6.2 THROUGH 4.6.4 WERE RE-WRITTEN. THESE DATA PROVIDED, AND DATA AVAILABLE. PARAGRAPH 4.6.10 NOTE, ADDED FURTHER EXPLANATION OF MINIMUM DELIVERED DATA. • PAGES 7 THROUGH 12, ALL FIGURE TITLES CHANGED TO HAVE DEVICE OPTIONS AND PACKAGE TYPES AT TOP OF PAGE, AND HAVE ALL FIGURES AT BOTTOM OF PAGE. • PAGE 9, MOVED FIGURE 4 TO PAGE 9 FROM PAGE 10 AS SHOWN IN PREVIOUS SPECIFICATION REVISION. • PAGE 12, FIGURE 7, TOTAL DOSE BIAS CURRENT REVISED BY ENGINEERING. • PAGE 13, TABLES I, II AND CORRESPONDING NOTES ALL ON ONE PAGE. • PAGE 8, CHANGED OUTLINE DRAWING PIN 1 NOTCH MOVED TO INSIDE LEAD LOCATION. J K • • L • M • N P DATE 03/26/02 05/19/03 Page 4, Changed initial rate of rads to 240. Page 4, Added: Out to ground voltage (shunt mode current limit…..10v and Note: Absolute maximum ratings are those values beyond which the life of a device may be impaired. Page 4, changed (shunt mode current voltage) to (sink mode current limit) per datasheet rev. D. 03/16/05 08/17/05 12/17/07 • PAGE 5, CHANGED IN BOTH PARAGRAPHS 4.2, 4.3 IN CONJUNCTION TO 3.3 CHANGED TO 3.4 AND PARAGRAPH 4.3 CHANGED 3.1.1 TO 3.1 AND 3.2.1 TO 3.1.1 PAGE 4 PARAGRAPH 3.11.1 CHANGED VERBIAGE. • • PAGE 5, PARAGRAPH 4.4.2 CHANGED VERBIAGE. PAGE 8, FIGURE 2 NOTE 2 ADDED TO LEAD THICKNESS. 06/27/08 LINEAR TECHNOLOGY CORPORATIION PDF created with pdfFactory trial version www.pdffactory.com 01/24/06 04/30/08 PAGE 2 OF 14 SPEC NO. 05-08-5016 1.0 RH1021-5, PRECISION 5V REFERENCE SCOPE: 1.1 2.0 REV. P This specification defines the performance and test requirements for a microcircuit processed to a space level manufacturing flow. APPLICABLE DOCUMENTS: 2.1 Government Specifications and Standards: the following documents listed in the Department of Defense Index of Specifications and Standards, of the issue in effect on the date of solicitation, form a part of this specification to the extent specified herein. SPECIFICATIONS: 2.2 3.0 MIL-PRF-38535 Integrated Circuits (Microcircuits) Manufacturing, General Specification for MIL-STD-883 Test Method and Procedures for Microcircuits MIL-STD-1835 Microcircuits Case Outlines Order of Precedence: In the event of a conflict between the documents referenced herein and the contents of this specification, the order of precedence shall be this specification, MIL-PRF-38535 and other referenced specifications. REQUIREMENTS: 3.1 General Description: This specification details the requirements for the RH1021-5, Precision 5V Reference, processed to space level manufacturing flow. 3.2 Part Number: 3.3 3.2.1 Option 1 – RH1021BMH-5 (TO5 Metal Can, 8 Leads) 3.2.2 Option 2 – RH1021CMH-5 (TO5 Metal Can, 8 Leads) 3.2.3 Option 3 – RH1021DMH-5 (TO5 Metal Can, 8 Leads) 3.2.4 Option 4 – RH1021CMW-5 (Glass Sealed Flatpack, 10 Leads) Part Marking Includes: 3.3.1 LTC Logo 3.3.2 LTC Part Number (See Paragraph 3.2) 3.3.3 Date Code 3.3.4 Serial Number 3.3.5 ESD Identifier per MIL-PRF-38535, Appendix A LINEAR TECHNOLOGY CORPORATIION PDF created with pdfFactory trial version www.pdffactory.com PAGE 3 OF 14 SPEC NO. 05-08-5016 3.4 REV. P RH1021-5, PRECISION 5V REFERENCE The Absolute Maximum Ratings: Input Voltage . . . . . . . . . . . . . . . . 40V Input / Output Voltage Differential . . . . . . . . . . 35V Output to Ground Voltage (Sink Mode Current Limit) . . . . . . . . . 10V Trim Pin – to – Ground Voltage Positive . . . . . . . . . . . . . . . Equal to VOUT . . . . . . . . . . . . . . . -20V Negative Output Short – Circuit Duration VIN = 35V . . . . . . . . . . . . . . . 10 sec VIN = < 20V . . . . . . . . . . . . . . Indefinite Operating Temperature Range . . . . . . . . . . . -55°C to 125°C . . . . . . . . . . . . -65°C to 150°C Storage Temperature Range Lead Temperature (Soldering, 10 sec.) . . . . . . . . . 300°C NOTE: Absolute maximum ratings are those values beyond which the life of a device may be impaired. 3.5 Electrostatic discharge sensitivity, ESDS, shall be Class 1. 3.6 Electrical Performance Characteristics: The electrical performance characteristics shall be as specified in Table I and Table II. 3.7 Electrical Test Requirements: Screening requirements shall be in accordance with 4.1 herein, MIL-STD-883, Method 5004, and as specified in Table IV herein. 3.8 Burn-In Requirement: 3.8.1 Options 1, 2, 3 (TO5): Static Burn-In, Figure 5 3.8.2 Option 4 (Glass Sealed Flatpack) : Static Burn-In, Figure 6 3.9 Delta Limit Requirement: Delta limit parameters are specified in Table III herein, are calculated after each burn-in, and the delta rejects are included in the PDA calculation. 3.10 Design, Construction, and Physical Dimensions: Detail design, construction, physical dimensions, and electrical requirements shall be as specified herein. 3.11 3.10.1.1 Mechanical / Packaging Requirements: Case outlines and dimensions are in accordance with Figure 1 (TO5/8 Leads) and Figure 2 (Glass Sealed Flatpack/10 Leads). 3.10.2 Terminal Connections: The terminal connections shall be as specified in Figure 3 (TO5/8 Leads) and Figure 4 (Glass Sealed Flatpack/10 Leads). 3.10.3 Lead Material and Finish: The lead material shall be Kovar for TO5 and alloy 42 for flatpack. The lead finish shall be hot solder dip (Finish letter A) in accordance with MIL-PRF-38535. Radiation Hardness Assurance (RHA): LINEAR TECHNOLOGY CORPORATIION PDF created with pdfFactory trial version www.pdffactory.com PAGE 4 OF 14 SPEC NO. 05-08-5016 4.0 REV. P RH1021-5, PRECISION 5V REFERENCE 3.11.1 The manufacturer shall perform a lot sample test as an internal process monitor for total dose radiation tolerance. The sample test is performed with MIL-STD-883 TM1019 Condition A as a guideline. 3.11.2 For guaranteed radiation performance to MIL-STD-883, Method 1019, total dose irradiation, the manufacturer will provide certified RAD testing and report through an independent test laboratory when required as a customer purchase order line item. 3.11.3 Total dose bias circuit is specified in Figure 7. 3.12 Wafer Lot Acceptance: Wafer lot acceptance shall be in accordance with MIL-PRF-38535, Appendix A, except for the following: Topside glassivation thickness shall be a minimum of 4KÅ. 3.13 Wafer Lot Acceptance Report: SEM is performed per MIL-STD-883, Method 2018 and copies of SEM photographs shall be supplied with the Wafer Lot Acceptance Report as part of a Space Data Pack when specified as a customer purchase order line item. VERIFICATION (QUALITY ASSURANCE PROVISIONS) 4.1 Quality Assurance Provisions: Quality Assurance provisions shall be in accordance with MIL-PRF-38535. Linear Technology is a QML certified company and all Rad Hard candidates are assembled on qualified Class S manufacturing lines. 4.2 Sampling and Inspection: Sampling and Inspection shall be in accordance with MIL-STD-883, Method 5005 with QML allowed and TRB approved deviations in conjunction with paragraphs 3.1.1, 3.2.1, and 3.4 of the test method. 4.3 Screening: Screening requirements shall be in accordance with MIL-STD-883, Method 5004 with QML allowed and TRB approved deviations in conjunction with paragraphs 3.1, 3.1.1, and 3.4 of the test method. Electrical testing shall be as specified in Table IV herein. 4.3.1 4.4 Analysis of catastrophic (open/short) failures from burn-in will be conducted only when a lot fails the burn-in or re-burn-in PDA requirements. Quality Conformance Inspection: Quality conformance inspection shall be in accordance with 4.2 and 4.3 herein and as follows: 4.4.1 Group A Inspection: Group A inspection shall be performed in accordance with 4.1 herein, per MIL-STD-883, Method 5005, and specified in Table IV herein. 4.4.2 Group B Inspection: When purchased, a full Group B is performed on an inspection lot. As a minimum, Subgroups 1-4 plus 6 are performed on every assembly lot, and Subgroup B2 (Resistance to Solvents / Mark Permanency) and Subgroup B3 (Solderability) are performed prior to the first shipment from any inspection lot and Attributes provided when a Full Space Data Pack is ordered. Subgroup B5 (Operating Life) is performed on each wafer lot. This subgroup may or may not be from devices built in the same package style as the current inspection lot. Attributes and variables data for this subgroup will be provided upon request at no charge. 4.4.2.1 Group B, Subgroup 2c = 10% Group B, Subgroup 3 = 10% Group B, Subgroup 5 = *5% (*per wafer or inspection lot whichever is the larger quantity) Group B, Subgroup 4 = 5% Group B, Subgroup 6 = 15% LINEAR TECHNOLOGY CORPORATIION PDF created with pdfFactory trial version www.pdffactory.com PAGE 5 OF 14 SPEC NO. 05-08-5016 REV. P RH1021-5, PRECISION 5V REFERENCE 4.4.2.2 All footnotes pertaining to Table IIa in MIL-STD-883, Method 5005 apply. The quantity (accept number) of all other subgroups are per MIL-STD-883, Method 5005, Table IIa. 4.4.3 4.5 4.6 Group D Inspection: When purchased, a full Group D is performed on an inspection lot. As a minimum, periodic full Group D sampling is performed on each package family for each assembly location every 26 weeks. A generic Group D Summary is provided when a full Space Data Pack is ordered. 4.4.3.1 Group D, Subgroups 3, 4 and 5 = 15% each (Sample Size Series). 4.4.3.2 All footnotes pertaining to Table IV in MIL-STD-883, Method 5005 apply. The quantity (accept number) or sample number and accept number of all other subgroups are per MIL-STD-883, Method 5005, Table IV. Source Inspection: 4.5.1 The manufacturer will coordinate Source Inspection at wafer lot acceptance and pre-seal internal visual. 4.5.2 The procuring activity has the right to perform source inspection at the supplier’s facility prior to shipment for each lot of deliverables when specified as a customer purchase order line item. This may include wafer lot acceptance and final data review. Deliverable Data: Deliverable data that will ship with devices when a Space Data Pack is ordered: 4.6.1 Lot Serial Number Sheets identifying all devices accepted through final inspection by serial number 4.6.2 100% attributes (completed lot specific traveler; includes Group A Summary) 4.6.3 Burn-In Variables Data and Deltas (if applicable) 4.6.4 Group B2, B3, and B5 Attributes (Variables data, if performed on lot shipping) 4.6.5 Generic Group D data (4.4.3 herein) 4.6.6 SEM photographs (3.13 herein) 4.6.7 Wafer Lot Acceptance Report (3.13 herein) 4.6.8 X-Ray Negatives and Radiographic Report 4.6.9 A copy of outside test laboratory radiation report if ordered 4.6.10 Certificate of Conformance certifying that the devices meet all the requirements of this specification and have successfully completed the mandatory tests and inspections herein Note: Items 4.6.1 and 4.6.10 will be delivered as a minimum, with each shipment. This is noted on the Purchase Order Review Form as “No Charge Data”. LINEAR TECHNOLOGY CORPORATIION PDF created with pdfFactory trial version www.pdffactory.com PAGE 6 OF 14 SPEC NO. 05-08-5016 5.0 REV. P RH1021-5, PRECISION 5V REFERENCE Packaging Requirements: Packaging shall be in accordance with Appendix A of MIL-PRF-38535. All devices shall be packaged in conductive material or packaged in anti-static material with an external conductive field shielding barrier. DEVICE OPTIONS 1, 2, 3 TO5 METAL CAN / 8 LEADS CASE OUTLINE θja = +150°C/W θjc = +40°C/W FIGURE 1 LINEAR TECHNOLOGY CORPORATIION PDF created with pdfFactory trial version www.pdffactory.com PAGE 7 OF 14 SPEC NO. 05-08-5016 REV. P RH1021-5, PRECISION 5V REFERENCE DEVICE OPTION 4 W10, GLASS SEALED FLATPACK / 10 LEADS CASE OUTLINE NOTE: 1. THIS DIMENSION ALLOWS FOR OFFCENTER LID, MENISCUS AND GLASS OVER RUN. NOTE: 2. INCREASE DIMENSION BY 0.003 INCH WHEN LEAD FINISH IS APPLIED (SOLDER DIPPED). θja = +170°C/W θjc = +40°C/W LINEAR TECHNOLOGY CORPORATIION PDF created with pdfFactory trial version www.pdffactory.com PAGE 8 OF 14 SPEC NO. 05-08-5016 REV. P RH1021-5, PRECISION 5V REFERENCE FIGURE 2 TERMINAL CONNECTIONS DEVICE OPTIONS 1, 2, 3, TO5 METAL CAN / 8 LEADS FIGURE 3 OPTION 4, GLASS SEALED FLATPACK / 10 LEADS FIGURE 4 LINEAR TECHNOLOGY CORPORATIION PDF created with pdfFactory trial version www.pdffactory.com PAGE 9 OF 14 SPEC NO. 05-08-5016 REV. P RH1021-5, PRECISION 5V REFERENCE BURN-IN CIRCUIT OPTIONS 1, 2, 3, TO5 METAL CAN / 8 LEADS FIGURE 5 LINEAR TECHNOLOGY CORPORATIION PDF created with pdfFactory trial version www.pdffactory.com PAGE 10 OF 14 SPEC NO. 05-08-5016 REV. P RH1021-5, PRECISION 5V REFERENCE BURN-IN CIRCUIT OPTION 4, GLASS SEALED FLATPACK / 10 LEADS FIGURE 6 LINEAR TECHNOLOGY CORPORATIION PDF created with pdfFactory trial version www.pdffactory.com PAGE 11 OF 14 SPEC NO. 05-08-5016 REV. P RH1021-5, PRECISION 5V REFERENCE TOTAL DOSE BIAS CIRCUIT FIGURE 7 LINEAR TECHNOLOGY CORPORATIION PDF created with pdfFactory trial version www.pdffactory.com PAGE 12 OF 14 SPEC NO. 05-08-5016 REV. P RH1021-5, PRECISION 5V REFERENCE TABLE I: ELECTRICAL CHARACTERISTICS (PRE-IRRADIATION) NOTE 8 TABLE II: ELECTRICAL CHARACTERISTICS (POST-IRRADIATION) NOTE 6 LINEAR TECHNOLOGY CORPORATIION PDF created with pdfFactory trial version www.pdffactory.com PAGE 13 OF 14 SPEC NO. 05-08-5016 REV. P RH1021-5, PRECISION 5V REFERENCE TABLE III: POST BURN-IN ENDPOINTS AND DELTA LIMIT REQUIREMENTS TA = 25°C APPLIES TO RH1021BM-5 AND RH1021DM-5 PARAMETER VOUT ENDPOINT LIMIT MIN MAX 4.95 5.05 DELTA MIN -0.003 MAX 0.003 UNITS V MAX 0.003 UNITS V APPLIES TO RH1021CM-5 PARAMETER VOUT ENDPOINT LIMIT MIN MAX 4.9975 5.0025 DELTA MIN -0.003 TABLE IV: ELECTRICAL TEST REQUIREMENTS LINEAR TECHNOLOGY CORPORATIION PDF created with pdfFactory trial version www.pdffactory.com PAGE 14 OF 14