R019 Reliability Data

RELIABILITY DATA
LF198 / LF398 LM198 / LM398
8/21/2006
• OPERATING LIFE TEST
PACKAGE
TYPE
SAMPLE
SIZE
OLDEST
DATE CODE
HERMETIC
PLASTIC DIP
NEWEST
DATE CODE
1,275
8342
75
8351
1,350
• HIGHLY ACCELERATED STRESS TEST AT +131°C/85%RH
PACKAGE
TYPE
SAMPLE
SIZE
OLDEST
DATE CODE
SOIC/SOT/MSOP
130
9433
130
• PRESSURE COOKER TEST AT 15 PSIG, +121°C
PACKAGE
TYPE
SAMPLE
SIZE
SAMPLE
SIZE
CERDIP
HERMETIC
PLASTIC DIP
SOIC/SOT/MSOP
CERDIP
HERMETIC
PLASTIC DIP
SOIC/SOT/MSOP
SAMPLE
SIZE
2,989.20
882.28
3,871.48
K DEVICE
(4)
HOURS
AT +85°C
9503
9310
9238
9842
9819
OLDEST
DATE CODE
NEWEST
DATE CODE
50
395
643
384
1,472
• THERMAL SHOCK FROM -65°C to +150°C
PACKAGE
TYPE
NEWEST
DATE CODE
NEWEST
DATE CODE
2,193
3,309
5,502
• TEMP CYCLE FROM -65°C to +150°C
PACKAGE
TYPE
9521
8733
OLDEST
DATE CODE
PLASTIC DIP
SOIC/SOT/MSOP
K DEVICE
HOURS (1)
AT +125°C
9412
8342
8344
9238
9412
9535
9842
9819
OLDEST
DATE CODE
NEWEST
DATE CODE
62.40
62.40
K DEVICE
HOURS
65.83
123.29
189.13
K DEVICE
CYCLES
5.00
17.00
193.73
38.40
254.13
K DEVICE
CYCLES
50
9412
9412
185
8613
9535
150
9415
9445
289
9427
9802
674
(1) Assumes Activation Energy = 1.0 Electron Volts
(2) Failure Rate Equivalent to +55°C, 60% Confidence Level = 1.61 FITS
(3) Mean Time Between Failures in Years = 70,855
(4) Assumes 20X Acceleration from 85°C to +131°C
Note: 1 FIT = 1 Failure in One Billion Hours.
Form: 00-03-6209B. R019
5.00
101.46
35.50
28.90
170.86
NUMBER
OF (2)
FAILURES
1
1
2
NUMBER
OF
FAILURES
0
0
NUMBER
OF
FAILURES
0
0
0
NUMBER
OF
FAILURES
0
0
0
0
0
NUMBER
OF
FAILURES
0
0
0
0
0
Rev 1