TI LF198H/883

LF198QML
LF198QML Monolithic Sample-and-Hold Circuits
Literature Number: SNOSAH9
LF198QML
Monolithic Sample-and-Hold Circuits
General Description
Features
The LF198 is a monolithic sample-and-hold circuit which
utilizes BI-FET technology to obtain ultra-high dc accuracy
with fast acquisition of signal and low droop rate. Operating
as a unity gain follower, dc gain accuracy is 0.002% typical
and acquisition time is as low as 6 µs to 0.01%. A bipolar
input stage is used to achieve low offset voltage and wide
bandwidth. Input offset adjust is accomplished with a single
pin, and does not degrade input offset drift. The wide bandwidth allows the LF198 to be included inside the feedback
loop of 1 MHz op amps without having stability problems.
Input impedance of 1010Ω allows high source impedances to
be used without degrading accuracy.
n Operates from ± 5V to ± 18V supplies
n Less than 10 µs acquisition time
n TTL, PMOS, CMOS compatible logic input
n 0.5 mV typical hold step at Ch = 0.01 µF
n Low input offset
n 0.002% gain accuracy
n Low output noise in hold mode
n Input characteristics do not change during hold mode
n High supply rejection ratio in sample or hold
n Wide bandwidth
Logic inputs on the LF198 are fully differential with low input
current, allowing direct connection to TTL, PMOS, and
CMOS. Differential threshold is 1.4V. The LF198 will operate
from ± 5V to ± 18V supplies.
P-channel junction FET’s are combined with bipolar devices
in the output amplifier to give droop rates as low as 5 mV/min
with a 1 µF hold capacitor. The JFET’s have much lower
noise than MOS devices used in previous designs and do
not exhibit high temperature instabilities. The overall design
guarantees no feed-through from input to output in the hold
mode, even for input signals equal to the supply voltages.
Ordering Information
NSC Part Number
JAN Part Number
NSC Package Number
Package Description
LF198H/883
5962–8760801GA
H08C
LF198WG-QMLV
5962–8760801VZA
WG14A
14LD Ceramic SOIC
8LD Metal Can
LF198WG/883
5962–8760801QZA
WG14A
14LD Ceramic SOIC
Connection Diagrams
Small-Outline Package
Metal Can Package
20122215
See NS Package Number WG14A
20122214
See NS Package Number H08C
© 2005 National Semiconductor Corporation
DS201222
www.national.com
LF198QMLMonolithic Sample-and-Hold Circuits
February 2005
LF198QML
Typical Connection and Performance Curve
Acquisition Time
20122232
20122216
Functional Diagram
20122201
www.national.com
2
LF198QML
Absolute Maximum Ratings (Note 1)
± 18V
Supply Voltage
Power Dissipation (Package Limitation) (Note 2)
500 mW
Operating Ambient Temperature Range
−55˚C to +125˚C
Maximum Junction Temperature (TJmax)
+150˚C
Input Voltage
Equal to Supply Voltage
Logic To Logic Reference Differential Voltage (Note 3)
+7V, −30V
Output Short Circuit Duration
Indefinite
Hold Capacitor Short Circuit Duration
10 sec
Lead Temperature (Soldering, 10 sec.)
260˚C
Thermal Resistance
θJA
Metal Can
(Still Air @ 0.5W)
Metal Can
(500 LF/Min Air Flow @ 0.5W)
160˚C/W
84˚C/W
Ceramic SOIC
(Still Air @ 0.5W)
140˚C/W
Ceramic SOIC
(500 LF/Min Air Flow @ 0.5W)
95˚C/W
θJC
Metal Can
48˚C/W
Ceramic SOIC
20˚C/W
Package Weight (typical)
Metal Can
TBD
Ceramic SOIC
415mg
ESD Tolerance (Note 7)
500V
Quality Conformance Inspection
Mil-Std-883, Method 5005 — Group A
Subgroup
Description
Temperature (˚C)
1
Static tests at
+25˚C
2
Static tests at
+125˚C
3
Static tests at
−55˚C
4
Dynamic tests at
+25˚C
5
Dynamic tests at
+125˚C
6
Dynamic tests at
−55˚C
7
Functional tests at
+25˚C
8A
Functional tests at
+125˚C
8B
Functional tests at
−55˚C
9
Switching tests at
+25˚C
10
Switching tests at
+125˚C
11
Switching tests at
−55˚C
3
www.national.com
LF198QML
Electrical Characteristics
The following specifications apply unless otherwise specified. VCC = ± 15V, RL = 10KΩ, VIN = 0V, CHOLD = 0.01 µF, Logic Reference Pin = 0V, Logic Pin = 4V
Symbol
ICC+
ICC-
VOS
Parameter
Positive Supply Current
Negative Supply Current
Input Offset Voltage
Max
Unit
Subgroups
5.5
mA
1, 2
6.5
mA
3
+VCC = 18V, -VCC = -18V,
Mode = "Sample"
5.5
mA
1, 2
6.5
mA
3
+VCC = 18V, -VCC = -18V,
Mode = "Hold"
5.5
mA
1, 2
6.5
mA
3
-5.5
mA
1, 2
-6.5
mA
3
+VCC = 18V, -VCC = -18V,
Mode = "Sample"
-5.5
mA
1, 2
-6.5
mA
3
+VCC = 18V, -VCC = -18V,
Mode = "Hold"
-5.5
mA
1, 2
-6.5
mA
3
Conditions
Notes
+VCC = 15V, -VCC = -15V
+VCC = 15V, -VCC = -15V
+VCC = 3V, -VCC = -7V
+VCC = 15V, -VCC = -15V
+VCC = 3.5V, -VCC = -26.5V
+VCC = 18V, -VCC = -18V
+VCC = 3.5V, -VCC = -32.5V
+VCC = 26.5V, -VCC = -3.5V
+VCC = 32.5V, -VCC = -3.5V,
Logic = 2.5V
+VCC = 7V, -VCC = -3V
IIB
Input Bias Current
+VCC = 3V, -VCC = -7V
+VCC = 15V, -VCC = -15V
+VCC = 3.5V, -VCC = -32.5V
+VCC = 32.5V, -VCC = -3.5V
+VCC = 7V, -VCC = -3V
ILeak(Cap)
Leakage Current into Hold
Capacitor
+VCC = 3V, -VCC = -7V
(Note 5)
+VCC = 3.5V, -VCC = -32.5V
+VCC = 32.5V, -VCC = -3.5V
+VCC = 7V, -VCC = -3V
www.national.com
Min
4
(Note 5)
-3.0
3.0
mV
1
-5.0
5.0
mV
2, 3
-3.0
3.0
mV
1
-5.0
5.0
mV
2, 3
-3.0
3.0
mV
1
2, 3
-5.0
5.0
mV
-3.0
3.0
mV
1
-5.0
5.0
mV
2, 3
-3.0
3.0
mV
1
-5.0
5.0
mV
2, 3
-3.0
3.0
mV
1
-5.0
5.0
mV
2, 3
-3.0
3.0
mV
1
-5.0
5.0
mV
2, 3
-3.0
3.0
mV
1
-5.0
5.0
mV
2, 3
-25
25
nA
1
-75
75
nA
2, 3
-25
25
nA
1
-75
75
nA
2, 3
-25
25
nA
1
-75
75
nA
2, 3
-25
25
nA
1
-75
75
nA
2, 3
-25
25
nA
1
-75
75
nA
2, 3
-100
100
pA
1
-100
100
pA
1
-100
100
pA
1
-100
100
pA
1
(Continued)
The following specifications apply unless otherwise specified. VCC = ± 15V, RL = 10KΩ, VIN = 0V, CHOLD = 0.01 µF, Logic Reference Pin = 0V, Logic Pin = 4V
Symbol
VHS
Parameter
Hold Step
Conditions
+VCC = 15V -VCC = -15V
+VCC = 3.5V, -VCC = -26.5V
+VCC = 26.5V, -VCC = -3.5V
AE
Gain Error
Notes
Min
Max
Unit
Subgroups
(Note 4)
-2.0
2.0
mV
1
-5.6
5.6
mV
2, 3
-2.5
2.5
mV
1
-5.6
5.6
mV
2, 3
(Note 4)
(Note 4)
-2.5
2.5
mV
1
-5.6
5.6
mV
2, 3
0.02
%
1
0.06
%
2, 3
0.005
%
1
0.02
%
2, 3
0.005
%
1
2, 3
+VCC = 7V, -VCC = -3V
+VCC = 3.5V, -VCC = -26.5V
+VCC = 32.5V, -VCC = -3.5V
+VCC = 26.5V, -VCC = -3.5V
ZI
Input Impedance
+VCC = 8V, -VCC = -28V
+VCC = 28V, -VCC = -8V
ZO
ICharge
Output Impedance
Capacitor Charging Current
+VCC = 28V, -VCC = -8V
Logic
Logic Pin Current
%
%
1
0.02
%
2, 3
10.0
GΩ
1
0.8
GΩ
2, 3
10.0
GΩ
1
0.8
GΩ
2, 3
2.0
Ω
1
4.0
Ω
2, 3
-25
-4.5
mA
1
-25
-3.0
mA
2, 3
4.5
25
mA
1
3.0
25
mA
2, 3
10
µA
1, 2, 3
1.0
µA
1
0.5
µA
2, 3
+VCC = 18V, -VCC = -18V
+VCC = 8V, -VCC = -28V
0.06
0.005
+VCC = 18V, -VCC = -18V,
Mode = "Sample", Logic = 7V
+VCC = 18V, -VCC = -18V,
Mode = "Hold", Logic = -30V
VOS
Input Offset Voltage
+VCC = 15V, -VCC = -15V,
IDrive = +1mA
-3.5
3.5
mV
1
-6.0
6.0
mV
2, 3
Delta VOS
Input Offset Voltage
+VCC = 15V, -VCC = -15V,
IDrive = +1mA to -1mA
-1.1
1.1
mV
1
-2.0
2.0
mV
2, 3
1
IOS+
Output Short Circuit Current
+VCC = 18V, -VCC = -18V
7.0
20
mA
IOS-
Output Short Circuit Current
+VCC = 18V, -VCC = -18V
-25
-7.0
mA
1
ILogicRef
Logic Reference Pin Current
+VCC = 18V, -VCC = -18V,
Mode = "Sample", Logic = 7V
-1.0
1.0
µA
1
-0.5
5.0
µA
2, 3
10
µA
1, 2, 3
+VCC = 18V, -VCC = -18V,
Mode = "Hold", Logic = -30V
PSRR
Power Supply Rejection Ratio
+VCC = 10V, -VCC = -15V
+VCC = 15V, -VCC = -10V
FTRR
Feed Through Rejection Ratio
+VCC = 3.5V, -VCC = -32.5V
+VCC = 32.5V, -VCC = -3.5V
VTH
Differential Logic Level
(Note 8)
5
80
dB
1
74
dB
2, 3
80
dB
1
74
dB
2, 3
86
dB
1
74
dB
2, 3
86
dB
1
74
dB
2, 3
V
1
0.8
2.4
www.national.com
LF198QML
Electrical Characteristics
LF198QML
Electrical Characteristics
(Continued)
The following specifications apply unless otherwise specified. VCC = ± 15V, RL = 10KΩ, VIN = 0V, CHOLD = 0.01 µF, Logic Reference Pin = 0V, Logic Pin = 4V
Symbol
VOS
(2nd Stg)
Parameter
2nd Stage VOS
Conditions
Notes
+VCC = 3.5V, -VCC = -32.5V
+VCC = 3V, -VCC = -7V
+VCC = 32.5V, -VCC = -3.5V
+VCC = 7V, -VCC = -3V
Min
Max
Unit
Subgroups
-35
+35
mV
1
2, 3
-50
+50
mV
-35
+35
mV
1
-50
+50
mV
2, 3
-35
+35
mV
1
-50
+50
mV
2, 3
-35
+35
mV
1
-50
+50
mV
2, 3
AC Parameters
The following specifcations apply unless otherwise specified. VCC = ± 15V, RL = 10KΩ, VIN = 0V, CHold = 0.01 µF, Logic Reference Pin = 0V, Logic Pin = 4V
Symbol
TAQ
Max
Unit
Subgroups
Delta VOUT = 10V,
CHold = 1000pF
6.0
µS
4
Delta VOUT = 10V,
CHold = 0.01µF
25
µS
4
Parameter
Acquisition Time
Conditions
Notes
Min
DC Parameters: Drift Values
The following conditions apply to all the following parameters, unless otherwise specified. VCC = ± 15V, RL = 10KΩ, VIN = 0V,
CHold = 0.01 µF, Logic Reference Pin = 0V, Logic Pin = 4V Deltas required for S-Level product ONLY.
Symbol
Parameters
Conditions
Notes
Min
Max
Unit
Subgroups
VOS
Input Offset Voltage
+VCC = 15V, -VCC = -15V
-0.5
0.5
mV
1
IIB
Input Bias Current
+VCC = 15V, -VCC = -15V
-2.5
2.5
nA
1
Note 1: “Absolute Maximum Ratings” indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is
functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed
specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test
conditions
Note 2: The maximum power dissipation must be derated at elevated temperatures and is dictated by TJMAX, θJA, and the ambient temperature, TA. The maximum
allowable power dissipation at any temperature is PD = (TJMAX − TA)/θJA, or the number given in the Absolute Maximum Ratings, whichever is lower. .
Note 3: Although the differential voltage may not exceed the limits given, the common-mode voltage on the logic pins may be equal to the supply voltages without
causing damage to the circuit. For proper logic operation, however, one of the logic pins must always be at least 2V below the positive supply and 3V above the
negative supply.
Note 4: Hold step is sensitive to stray capacitive coupling between input logic signals and the hold capacitor. 1 pF, for instance, will create an additional 0.5 mV step
with a 5V logic swing and a 0.01µF hold capacitor. Magnitude of the hold step is inversely proportional to hold capacitor value.
Note 5: Leakage current is measured at a junction temperature of 25˚C. The effects of junction temperature rise due to power dissipation or elevated ambient can
be calculated by doubling the 25˚C value for each 11˚C increase in chip temperature. Leakage is guaranteed over full input signal range.
Note 6: See Definition of Terms
Note 7: Human body model, 100pF discharged through 1.5KΩ
Note 8: Parameter tested go no go only for Vth test.
www.national.com
6
LF198QML
Typical Performance Characteristics
Aperture Time
(Note 6)
Dielectric Absorption
Error in Hold Capacitor
20122217
20122218
Dynamic Sampling Error
Output Droop Rate
20122219
20122220
“Hold” Settling Time
(Note 6)
Hold Step
20122221
20122222
7
www.national.com
LF198QML
Typical Performance Characteristics
(Continued)
Leakage Current into Hold
Capacitor
Phase and Gain (Input to
Output, Small Signal)
20122223
20122224
Gain Error
Power Supply Rejection
20122226
20122225
Output Short Circuit Current
Output Noise
20122227
20122228
Note 9: See Definition
www.national.com
8
LF198QML
Typical Performance Characteristics
(Continued)
Feedthrough Rejection Ratio
(Hold Mode)
Input Bias Current
20122230
20122229
Output Transient at Start
of Sample Mode
Hold Step vs Input Voltage
20122231
20122212
Output Transient at Start
of Hold Mode
20122213
9
www.national.com
LF198QML
Logic Input Configurations
TTL & CMOS
3V ≤ VLOGIC (Hi State) ≤ 7V
20122233
Threshold = 1.4V
20122234
Threshold = 1.4V*Select for 2.8V at pin 8
CMOS
7V ≤ VLOGIC (Hi State) ≤ 15V
20122235
Threshold = 0.6 (V+) + 1.4V
20122236
Threshold = 0.6 (V+) − 1.4V
Op Amp Drive
20122237
Threshold ≈ +4V
20122238
Threshold = −4V
www.national.com
10
HOLD CAPACITOR
Hold step, acquisition time, and droop rate are the major
trade-offs in the selection of a hold capacitor value. Size and
cost may also become important for larger values. Use of the
curves included with this data sheet should be helpful in
selecting a reasonable value of capacitance. Keep in mind
that for fast repetition rates or tracking fast signals, the
capacitor drive currents may cause a significant temperature
rise in the LF198.
A significant source of error in an accurate sample and hold
circuit is dielectric absorption in the hold capacitor. A mylar
cap, for instance, may “sag back” up to 0.2% after a quick
change in voltage. A long sample time is required before the
circuit can be put back into the hold mode with this type of
capacitor. Dielectrics with very low hysteresis are polystyrene, polypropylene, and Teflon. Other types such as mica
and polycarbonate are not nearly as good. The advantage of
polypropylene over polystyrene is that it extends the maximum ambient temperature from 85˚C to 100˚C. Most ceramic capacitors are unusable with > 1% hysteresis. Ceramic “NPO” or “COG” capacitors are now available for
125˚C operation and also have low dielectric absorption. For
more exact data, see the curve Dielectric Absorption Error.
The hysteresis numbers on the curve are final values, taken
after full relaxation. The hysteresis error can be significantly
reduced if the output of the LF198 is digitized quickly after
the hold mode is initiated. The hysteresis relaxation time
constant in polypropylene, for instance, is 10 — 50 ms. If
A-to-D conversion can be made within 1 ms, hysteresis error
will be reduced by a factor of ten.
A curve labeled Aperture Time has been included for sampling conditions where the input is steady during the sampling period, but may experience a sudden change nearly
coincident with the “hold” command. This curve is based on
a 1 mV error fed into the output.
A second curve, Hold Settling Time indicates the time required for the output to settle to 1 mV after the “hold”
command.
DIGITAL FEEDTHROUGH
Fast rise time logic signals can cause hold errors by feeding
externally into the analog input at the same time the amplifier
is put into the hold mode. To minimize this problem, board
layout should keep logic lines as far as possible from the
analog input and the Ch pin. Grounded guarding traces may
also be used around the input line, especially if it is driven
from a high impedance source. Reducing high amplitude
logic signals to 2.5V will also help.
DC AND AC ZEROING
DC zeroing is accomplished by connecting the offset adjust
pin to the wiper of a 1 kΩ potentiometer which has one end
tied to V+ and the other end tied through a resistor to ground.
The resistor should be selected to give ≈0.6 mA through the
1k potentiometer.
AC zeroing (hold step zeroing) can be obtained by adding an
inverter with the adjustment pot tied input to output. A 10 pF
capacitor from the wiper to the hold capacitor will give ± 4 mV
hold step adjustment with a 0.01 µF hold capacitor and 5V
logic supply. For larger logic swings, a smaller capacitor
( < 10 pF) may be used.
Guarding Technique
LOGIC RISE TIME
For proper operation, logic signals into the LF198 must have
a minimum dV/dt of 1.0 V/µs. Slower signals will cause
excessive hold step. If a R/C network is used in front of the
logic input for signal delay, calculate the slope of the waveform at the threshold point to ensure that it is at least
1.0 V/µs.
SAMPLING DYNAMIC SIGNALS
Sample error to moving input signals probably causes more
confusion among sample-and-hold users than any other parameter. The primary reason for this is that many users make
the assumption that the sample and hold amplifier is truly
locked on to the input signal while in the sample mode. In
actuality, there are finite phase delays through the circuit
creating an input-output differential for fast moving signals.
20122205
Use 10-pin layout. Guard around Chis tied to output.
11
www.national.com
LF198QML
In addition, although the output may have settled, the hold
capacitor has an additional lag due to the 300Ω series
resistor on the chip. This means that at the moment the
“hold” command arrives, the hold capacitor voltage may be
somewhat different than the actual analog input. The effect
of these delays is opposite to the effect created by delays in
the logic which switches the circuit from sample to hold. For
example, consider an analog input of 20 Vp-p at 10 kHz.
Maximum dV/dt is 0.6 V/µs. With no analog phase delay and
100 ns logic delay, one could expect up to (0.1 µs) (0.6V/µs)
= 60 mVerror if the “hold” signal arrived near maximum dV/dt
of the input. A positive-going input would give a +60 mV
error. Now assume a 1 MHz (3 dB) bandwidth for the overall
analog loop. This generates a phase delay of 160 ns. If the
hold capacitor sees this exact delay, then error due to analog
delay will be (0.16 µs) (0.6 V/µs) = −96 mV. Total output error
is +60 mV (digital) −96 mV (analog) for a total of −36 mV. To
add to the confusion, analog delay is proportioned to hold
capacitor value while digital delay remains constant. A family
of curves (dynamic sampling error) is included to help estimate errors.
Application Hints
LF198QML
Typical Applications
Sample and Difference Circuit
(Output Follows Input in Hold Mode)
X1000 Sample & Hold
20122240
VOUT = VB + ∆VIN(HOLD MODE)
20122239
*For lower gains, the LM108 must be frequency compensated
Ramp Generator with Variable Reset Level
Integrator with Programmable Reset Level
20122242
20122243
www.national.com
12
LF198QML
Typical Applications
(Continued)
Output Holds at Average of Sampled Input
Increased Slew Current
20122246
20122247
Reset Stabilized Amplifier (Gain of 1000)
Fast Acquisition, Low Droop Sample & Hold
20122249
20122250
13
www.national.com
LF198QML
Typical Applications
(Continued)
Synchronous Correlator for Recovering
Signals Below Noise Level
2–Channel Switch
20122253
20122252
A
B
Gain
1 ± 0.02%
1 ± 0.2%
ZIN
1010Ω
47 kΩ
BW
. 1 MHz
. 400 kHz
Crosstalk
−90 dB
−90 dB
≤ 6 mV
≤ 75 mV
@ 1 kHz
Offset
DC & AC Zeroing
Staircase Generator
20122255
*Select for step height
20122259
50k → ≅ 1V Step
www.national.com
14
LF198QML
Typical Applications
(Continued)
Differential Hold
Capacitor Hysteresis Compensation
20122256
20122257
**Adjust for amplitude
Hold Settling Time: The time required for the output to
settle within 1 mV of final value after the “hold” logic command.
Dynamic Sampling Error: The error introduced into the
held output due to a changing analog input at the time the
hold command is given. Error is expressed in mV with a
given hold capacitor value and input slew rate. Note that this
error term occurs even for long sample times.
Aperture Time: The delay required between “Hold” command and an input analog transition, so that the transition
does not affect the held output.
Definition of Terms
Hold Step: The voltage step at the output of the sample and
hold when switching from sample mode to hold mode with a
steady (dc) analog input voltage. Logic swing is 5V.
Acquisition Time: The time required to acquire a new analog input voltage with an output step of 10V. Note that
acquisition time is not just the time required for the output to
settle, but also includes the time required for all internal
nodes to settle so that the output assumes the proper value
when switched to the hold mode.
Gain Error: The ratio of output voltage swing to input voltage swing in the sample mode expressed as a per cent
difference.
15
www.national.com
LF198QML
Revision History Section
Date
Released
02/25/05
www.national.com
Revision
A
Section
Originator
New release, Corporate format
L. Lytle
16
Changes
1 MDS converted to corp. datasheet
format. MNLF198–X Rev 3B0 MDS to be
archived. Change has been made to
Electrical Section, Parameter IOS- . Max
limit was 7.0 now is −7.0 confirmed with
SG. Added note Parameter tested go no
go to VTH test.
LF198QML
Physical Dimensions
inches (millimeters) unless otherwise noted
Metal Can Package (H)
NS Package Number H08C
14 LD Ceramic SOIC (WG)
NS Package Number WG14A
17
www.national.com
LF198QMLMonolithic Sample-and-Hold Circuits
Notes
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves
the right at any time without notice to change said circuitry and specifications.
For the most current product information visit us at www.national.com.
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS
WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR
CORPORATION. As used herein:
1. Life support devices or systems are devices or systems
which, (a) are intended for surgical implant into the body, or
(b) support or sustain life, and whose failure to perform when
properly used in accordance with instructions for use
provided in the labeling, can be reasonably expected to result
in a significant injury to the user.
2. A critical component is any component of a life support
device or system whose failure to perform can be reasonably
expected to cause the failure of the life support device or
system, or to affect its safety or effectiveness.
BANNED SUBSTANCE COMPLIANCE
National Semiconductor manufactures products and uses packing materials that meet the provisions of the Customer Products
Stewardship Specification (CSP-9-111C2) and the Banned Substances and Materials of Interest Specification (CSP-9-111S2) and contain
no ‘‘Banned Substances’’ as defined in CSP-9-111S2.
National Semiconductor
Americas Customer
Support Center
Email: [email protected]
Tel: 1-800-272-9959
www.national.com
National Semiconductor
Europe Customer Support Center
Fax: +49 (0) 180-530 85 86
Email: [email protected]
Deutsch Tel: +49 (0) 69 9508 6208
English Tel: +44 (0) 870 24 0 2171
Français Tel: +33 (0) 1 41 91 8790
National Semiconductor
Asia Pacific Customer
Support Center
Email: [email protected]
National Semiconductor
Japan Customer Support Center
Fax: 81-3-5639-7507
Email: [email protected]
Tel: 81-3-5639-7560
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products
Applications
Audio
www.ti.com/audio
Communications and Telecom www.ti.com/communications
Amplifiers
amplifier.ti.com
Computers and Peripherals
www.ti.com/computers
Data Converters
dataconverter.ti.com
Consumer Electronics
www.ti.com/consumer-apps
DLP® Products
www.dlp.com
Energy and Lighting
www.ti.com/energy
DSP
dsp.ti.com
Industrial
www.ti.com/industrial
Clocks and Timers
www.ti.com/clocks
Medical
www.ti.com/medical
Interface
interface.ti.com
Security
www.ti.com/security
Logic
logic.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Power Mgmt
power.ti.com
Transportation and Automotive www.ti.com/automotive
Microcontrollers
microcontroller.ti.com
Video and Imaging
RFID
www.ti-rfid.com
OMAP Mobile Processors
www.ti.com/omap
Wireless Connectivity
www.ti.com/wirelessconnectivity
TI E2E Community Home Page
www.ti.com/video
e2e.ti.com
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2011, Texas Instruments Incorporated