INFINEON BGX50A_07

BGX50A...
Silicon Switching Diode Array
• Bridge configuration
• High-speed switching diode chip
• Pb-free (RoHS compliant) package 1)
• Qualified according AEC Q101
BGX50A
"
!
, !
, "
,
, Type
BGX50A
Package
SOT143
Configuration
bridge
Marking
U1s
Maximum Ratings at TA = 25°C, unless otherwise specified
Parameter
Symbol
Diode reverse voltage
VR
50
Peak reverse voltage
VRM
70
Forward current
IF
140
Non-repetitive peak surge forward current
IFSM
-
Total power dissipation
Ptot
210
mW
Junction temperature
Tj
150
°C
Storage temperature
Tstg
Thermal Resistance
Parameter
Symbol
Junction - soldering point 2)
RthJS
Value
Unit
V
mA
TS ≤ 74°C
-65 ... 150
Value
Unit
360
K/W
BGX50A
1Pb-containing
2For
package may be available upon special request
calculation of RthJA please refer to Application Note Thermal Resistance
1
2007-03-27
BGX50A...
Electrical Characteristics at TA = 25°C, unless otherwise specified
Parameter
Symbol
Values
min.
typ. max.
DC Characteristics
Breakdown voltage
V(BR)
Reverse current
IR
Unit
µA
VR = 50 V
-
-
0.2
VR = 50 V, TA = 150 °C
-
-
100
VF
-
-
1.3
V
CT
-
-
1.5
pF
trr
-
-
6
ns
Forward voltage
IF = 100 mA
AC Characteristics
Diode capacitance
VR = 0 V, f = 1 MHz
Reverse recovery time
IF = 10 mA, IR = 10 mA, measured at IR = 1mA ,
RL = 100 Ω
Test circuit for reverse recovery time
D.U.T.
ΙF
Pulse generator: tp = 100ns, D = 0.05, tr = 0.6ns,
Ri = 50Ω
Oscillograph
Oscillograph: R = 50Ω, tr = 0.35ns, C ≤ 1pF
EHN00019
2
2007-03-27
BGX50A...
Reverse current IR = ƒ (TA)
Forward Voltage VF = ƒ (TA)
IF = Parameter
VR = Parameter
ΙR
10 5
nA
BGX 50A
EHB00146
BGX 50A
1.0
V
Ι F = 100 mA
VF
V R = 70 V
10 4
EHB00149
max.
5
10 mA
25V
70V
10 3
1 mA
0.5
5
0.1 mA
typ.
10 2
5
10 1
0
50
100
˚C
0
150
0
50
100
˚C
TA
TA
Forward current IF = ƒ (VF)
Peak forward current IFM = ƒ (tp)
TA = 25°C
TA = 25°C
150
ΙF
BGX 50A
EHB00147
10 2
Ι FM
mA
BGX 50A
EHB00148
A
D=
tp
T
10 1
100
tp
T
D=
0.005
0.01
0.02
0.05
0.1
0.2
5
typ
150
max
10 0
50
5
0
0
0.5
1.0
V
10 -1 -6
10
1.5
VF
10 -5
10 -4
10 -3
10 -2
s
10 0
t
3
2007-03-27
BGX50A...
Forward current IF = ƒ (T S)
BGX50A
160
mA
IF
120
100
80
60
40
20
0
0
15
30
45
60
75
90 105 120 °C
150
TS
4
2007-03-27
Package SOT143
BGX50A...
2
0.1 MAX.
10˚ MAX.
1
1 ±0.1
0.2
0.8 +0.1
-0.05
0.4 +0.1
-0.05
A
5
0...8˚
0.2 M A
0.25 M B
1.7
0.08...0.1
1.3 ±0.1
3
2.4 ±0.15
4
B
10˚ MAX.
2.9 ±0.1
1.9
0.15 MIN.
Package Outline
Foot Print
1.2
0.8
0.9
1.1
0.9
0.8 1.2 0.8
0.8
Marking Layout (Example)
RF s
56
Manufacturer
Pin 1
2005, June
Date code (YM)
BFP181
Type code
Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel
Reel ø330 mm = 10.000 Pieces/Reel
0.2
2.6
8
4
Pin 1
3.15
1.15
5
2007-03-27
BGX50A...
Edition 2006-02-01
Published by
Infineon Technologies AG
81726 München, Germany
© Infineon Technologies AG 2007.
All Rights Reserved.
Attention please!
The information given in this dokument shall in no event be regarded as a guarantee
of conditions or characteristics (“Beschaffenheitsgarantie”). With respect to any
examples or hints given herein, any typical values stated herein and/or any information
regarding the application of the device, Infineon Technologies hereby disclaims any
and all warranties and liabilities of any kind, including without limitation warranties of
non-infringement of intellectual property rights of any third party.
Information
For further information on technology, delivery terms and conditions and prices
please contact your nearest Infineon Technologies Office (www.infineon.com).
Warnings
Due to technical requirements components may contain dangerous substances.
For information on the types in question please contact your nearest
Infineon Technologies Office.
Infineon Technologies Components may only be used in life-support devices or
systems with the express written approval of Infineon Technologies, if a failure of
such components can reasonably be expected to cause the failure of that
life-support device or system, or to affect the safety or effectiveness of that
device or system.
Life support devices or systems are intended to be implanted in the human body,
or to support and/or maintain and sustain and/or protect human life. If they fail,
it is reasonable to assume that the health of the user or other persons
may be endangered.
6