Liebert NX UPS; Site Planning Data; 60Hz (R02/08) (SL-25220)

LIEBERT® NX™ 3-PHASE UPS: 10-30KVA, 60HZ, 208VAC - SITE PLANNING DATA
The Liebert NX is a true on-line, double conversion, General
three-phase UPS system that delivers complete,
INPUT
centralized power protection for mission-critical
systems.
Voltage
Specifications
OUTPUT
120/208VAC, 60Hz
3-phase, 4-wire plus ground
Voltage
120/208VAC, 60Hz
3-phase, 3- or 4-wire plus ground
±5%
Frequency Range 57-63Hz
Voltage
Adjustment
Range
Current
Distortion
4% maximum reflected THD
at full load
Voltage
Regulation
1% for balanced load
2% for 100% unbalanced load
Current Limit
125% of full load input current
Current
Walk-In
Dynamic
Regulation
±5% deviation for 100% load step
±1% for loss or return of AC input
20 seconds to full load
Power Factor
0.99 lagging minimum
at full load
Transient
Recover to ±5% of output voltage
Response Time within 1/2 cycle
Voltage Range
without derating
+10%, -20%
Sustains input surges without
damage, per criteria listed in
IEC 1000-4-5
Surge
Protection
ENVIRONMENTAL
Operating
Temperature
UPS: 32° to 104°F (0-40°C)
Battery: 68° to 86°F (20-30°C)
-4° to 158°F
Designed to meet the high availability power needs Non-Operating
(-20° to 70°C)
of a wide variety of IT applications, the UPS com- Temperature
bines compact size, advanced operating features
Relative Humidity 0-95% non-condensing
and low cost of ownership.
• Increases growth flexibility by handling larger
loads, plus the ability to parallel 20 and 30 kVA
modules for increased capacity and redundancy.
• Achieves higher availability by reducing the
number of UPS units required to power your
room.
• Reduces total cost of ownership through the use
of longer life batteries and simplified preventive
maintenance.
Voltage
Distortion
For linear loads, 1% THD
Less than 4% THD for 100%
nonlinear loads without kVA/kW
derating
Phasing
Balance
120° ±0.5° for balanced load
120° ±1° for 100% unbalanced load
Frequency
Regulation
±0.05% single module
±0.25% paralleled modules
Load Power
Factor Range
0.70 lagging to 0.95 leading without
derating
Overload
125% of full load for 10 minutes
150% for one minute, with true
sinusoidal waveform
Operating
Altitude
Up to 3,300 ft. (1,000m)
without derating
STANDARDS
Acoustical
Noise
Less than 54 dBA typical,
measured 3.3 ft. (1m) from the
unit
Listed to UL 1778 UPS standards, and CSA certified.
Meets current requirements for safe high performance
UPS operation.
Internal Battery
Battery Time (Minutes)
Model
10kVA
15kVA
20kVA
30kVA
Added Battery Weight
lb. (kg)
FR
26
14
9
—
550 (250)
HR
45
26
17
9
648 (294)
1
Liebert® NX™ 3-Phase UPS: 10-30kVA, 60Hz, 208VAC - Site Planning Data
Site Planning Data - 10-30kVA, 60Hz, 208VAC
UPS Rating
Voltage
AC Input
Current (A)
kVA
kW
Input
Output
Nom.
Max.
Battery
Rec. Nom.
OCPD VDC
Max.
Discharge
AC Output
Mechanical Data
Current
Nom.
Dimensions - WxDxH
in. (mm)
OCPD
Weight
lb. (kg)
Heat Dis.
BTU/hr (kWH)
Cooling Air
CFM (m3/hr)
10
8
208
208
28
35
45
288
37A
28
40
24x32.5x63 (610x826x1600)
450 (205)
2,800 (0.82)
384 (652)
15
12
208
208
42
53
70
288
55A
42
60
24x32.5x63 (610x826x1600)
450 (205)
4,200 (1.23)
558 (948)
20
16
208
208
56
70
90
288
73A
56
70
24x32.5x63 (610x826x1600)
550 (250)
5,500 (1.61)
522 (886)
30
24
208
208
83
104
125
288
110A
84
125
24x32.5x63 (610x826x1600)
550 (250)
8,300 (2.43)
834 (1417)
1
2,3,5,8,12
6
4
1,3,8,12
1,3,8,12
6
13
14
—
—
See Notes for Table (below):
Notes for Table
Notes for Table (continued)
1.
11. Top or bottom cable entry through removable access plates. Punch plate to
suit conduit size, then replace.
12. Control wiring and power wiring must be run in separate conduit.
13. Dimensions shown include an internal battery.
14. Weights shown do not include an internal battery nor optional cabinets or
features.
Nominal (Nom) current is based on full rated output load at nominal input
voltage.
2. Maximum (Max) current (125% of nominal) is short duration for battery
recharge conditions.
3. UPS input and bypass cables must be run in separate conduit from output
cables.
4. Nominal battery voltage is shown at 2.0 volts/cell per NEC 480-2.
5. For Single Input units only.
For Dual Input units, see “Electrical Data Specification Sheet, 10-30kVA
UPS Module, Single or Dual Input Liebert NX - U3813041.”
6. OCPD = Overcurrent Protection Device. Recommended AC input and AC
output overcurrent protection represents 125% of nominal full load current
(continuous) plus 100% of recharge current (non-continuous) per NEC 215.
7. Minimum-sized grounding conductors to be per NEC 250-122. Parity-sized
ground conductors are recommended. Neutral conductors to be sized for full
capacity per NEC 310-15 (b)(4). References are per NEC 1999.
8. Wiring requirements:
AC Input:
3-phase, 4-wire, plus ground
AC Output: 3-phase, 3- or 4-wire, plus ground
9. All wiring is to be in accordance with national and local electric codes.
10. Minimum access clearance is 3 ft. (0.9m) front and 18 in. (457mm) above
the UPS.
Additional Notes
• If site configuration includes a backup emergency generator, it is recommended that the engine generator set be properly sized and equipped for a
UPS application. Generator options would typically include an isochronous
governor (generator frequency regulation) and a UPS-compatible regulator
(generator voltage regulation). Consult generator manufacturer for required
generator options and sizing.
• If site configuration includes an automatic transfer switch, refer to Liebert
Power Line titled “Criteria for Application of Automatic Transfer Switches
(ATS) With Uninterruptible Power Supply (UPS) Systems,” publication
91K-PLT-48-02. It is also recommended that the transfer switch be equipped
with auxiliary contacts for UPS “on generator” current limit. Consult transfer
switch manufacturer for required transfer switch options and sizing.
• If site configuration requires an external isolated maintenance bypass circuit,
it should be noted that utility AC input might not be in phase with the UPS AC
output. Consult a Liebert sales representative or applications engineer.
© 2008 Liebert Corporation
All rights reserved throughout the world. Specifications subject to change without notice.
® Liebert is a registered trademark of Liebert Corporation.
All names referred to are trademarks or registered trademarks of their respective owners.
SL-25220_REV01_02-08
2
Technical Support / Service
United States
800-222-5877 (Outside U.S. 614-841-6755)
[email protected]
Web site: www.liebert.com
1050 Dearborn Drive
P.O. Box 29186
Columbus, OH 43229