Cabinet Cooler HIGH PERFORMANCE AIR CONDITIONING Cabinet Cooler is the indoor package air conditioner, direct expansion with built-in air cooled condenser especially designed for telecommunications sites like BTS, Fibre Optic Networks and other technological environments. Energy Saving And Cost Effective Cooling The most modern design and components such as scroll compressor, plug-type fans and the freecooling mode assure high energy saving and greatly reduce running and lifetime cost. High Power Density Rate Ease And Flexibility Of Installation More and more applications in modern telecommunications networks are based on small enclosures with an increasing need for reduced dimensions but with high data process intensity. Cabinet Cooler is the answer to the need of providing high refrigerating power in a small environment with up to 6 kW cooling capacity and a 600x300x1600 mm (WxDxH) frame. A full range of air delivery directions is available: downflow, frontal, combined frontal and lateral, which makes the unit suitable for several applications and positioning in containers and cabinets . It can be mounted on slides, in the rack, on the door and along the side wall. High Reliability Dedicated Accessories Evaporator fan, damper and control are powered by 48VDC emergency power sources in case of mains failure. Continued ventilation and the optional maximised freecooling assure constant operation of the telecommunications equipment and continued revenue from the site. The 48VDC supply increases the lifetime and reliability of the microprocessor and unit. Mount the especially designed grille to optimise condensing airflow in the direct expansion mode. This prevents short circuit in the free-cooling mode and any water intrusion. Model Cabinet Cooler CC Air supply Main power supply Emergency power supply (standard) Performances Total cooling capacity (1) Sensible cooling capacity (1) Compressor AC power input (1) Condenser fan AC power input (1) Evaporator fan DC power input (1) Evaporator airflow Condenser max.airflow Freecooling max.airflow Outdoor sound pressure level (2) Indoor sound pressure level (2) Max.ambient temperature (3) Refrigeration Circuit Compressor type / Quantity Refrigerant Expansion device Evaporator Fan Quantity / type / poles DC version Driven Condenser Fan Quantity / type / pole Driven / motor protection Control system Filter type / efficiency (CEN-EU) Electric heating (opt) Cabinet Frame Painting Insulation type / thickness Width Depth Height Weight kW kW kW kW kW m3/h m3/h m3/h dB(A) dB(A) °C 03 05 Frontal Downflow / Underflow / Side 230V/1Ph+N+PE/50HZ 48V DC 06 3,86 3,32 1,32 0,25 0,053 820 1.600 700 62 63,5 45 4,86 4,86 1,88 0,25 0,185 1.450 1.600 1.270 64 65,8 45 5,74 5,29 2,63 0,25 0,185 1.450 1.600 1.270 66 66,7 41 scroll / 1 R407C thermostatic valve 2/plug/direct kW 2/plug/4 direct / IP44 variable speed G3 1,5 -/mm mm mm mm kg galvanized steel polyester - RAL7035 polyurethane class A1 / 10 600 300 1.600 124 122 125 (1) Reference conditions are 27°C, &47% R.H indoor, 35°C outdoor; nominal power supply (2) Measured with outdoor temperature 35°C, 2 meters from the unit, free field conditions (3) Maximum outdoor temperature referred to indoor air temperature =24°C Freecooling damper Condenser fans Damper motor Room air filter Evaporator coil Evaporator fans Condenser coil Compressor Electric panel/Control Direct expansion mode Liebert HIROSS Headquarters Via Leonardo da Vinci, 8 35028 - Piove di Sacco (PD) tel. +39.0499719311 fax +39.0499719053 [email protected] High Performance Air Conditioning Via Leonardo da Vinci, 8 35028 - Piove di Sacco (PD) tel. +39.0499719311 fax +39.0499719053 [email protected] Uninterruptible Power Supply Via Gioacchino Rossini, 6 20098 - San Giuliano Milanese (MI) tel. +39.02982501 fax +39.0298250337 [email protected] www.liebert-hiross.com Freecooling mode Services Via Gioacchino Rossini, 6 20098 - San Giuliano Milanese (MI) tel. +39.02982501 fax +39.0298250338 [email protected] CABINET COOLER/E/103227/02-03/Conte+Oggioni+Partners/Printed in Italy General Features