Indoor/Outdoor Process Chiller Designed for GE Signa or 1.5T Excite • • • • • • • • Dedicated, equipment-matched cooling supplies the proper temperature and water flow year round. Factory-tested, piped, wired, and charged for hassle-free start-up and operation. Clean, non-ferrous cooling loop, required for sensitive medical equipment. Local service and parts for quick and knowledgeable maintenance and service. Optional switch-over to alternate water source provides redundant continuous operation. Optional remote monitoring systems keep you informed of chiller operation. Standard product ETL/CSA certified. ISO 9000 certified company. Signa Horizon & CV Specifications Fluid Specified Water/Glycol Max Heat Dissipation - BTUH (kW) 28,320 (8.3) Fluid Temperature Range, °F (°C) 40-82 (4-28) Temperature Gradient N/A Fluid Flow Rate - GPM (l/m) 2.1 (8.0) Fluid Pressure Drop - PSI (kPa) 36.0 (248) Liebert Process Chiller Specifications Model Number PS036A PS036A PS036A Fluid Circulated Water Ethylene Glycol Propylene Glycol Net Cooling Capacity - BTUH (kW) 29,500 (8.6) 29,600 (8.7) 28,800 (8.4) Leaving Fluid Temperature ° F (° C) 50 (10) 53 (11.7) 56 (13.3) Fluid Flow Rate - GPM (l/m) 5.3 (20.1) 5.3 (20.1) 5.3 (20.1) Signa Horizon & CV Pressure Drop - PSI (kPa) 36.0 (248) 48 (331) 55.1 (380) Chiller Pressure Drop - PSI (kPa) 5.1 (35.2) 6.8 (46.9) 7.8 (53.8) Pump Total Head - PSI (kPa) 64.9 (448) 64.9 (448) 64.9 (448) 3 (2.2) 3 (2.2) 3 (2.2) Pump HP (kW) Indoor/Outdoor Process Chiller Designed for GE Signa or 1.5T Excite 1 Model No. A-Width Inches (mm) B-Height Inches (mm) C-Depth Inches (mm) Weight Lbs. (kg) Voltage (60 Hz) Voltage (50 Hz) PS036A 36 (914) 48 (1219) 32.5 (825) 515 (233) 460, 3-phase 208/230, 1- or 3-phase 400, 3-phase 200/230, 1- or 3-phase Standard Features Optional Ship-Loose Accessories • • • • • • • • • • • • • • • • • • • • Indoor/outdoor cabinet Hermetic compressor Refrigerant dehydrator Expansion valve Refrigerant receiver Stainless steel expansion tank Pressure relief valve Hot gas bypass capacity control valve Stainless steel pump Optional Features • Refrigerant gauges and expansion tank heater Emergency Water Switchover (EWS) module Enviro-source emergency bypass Fluid pressure gauge Check valve Dial thermometer Relief valve Circuit setter Ball valve High temperature thermostat Low flow switch Liebert RCM4 remote alarm monitor Required Options • 3 HP pump, SFA #E6569-06 • Bypass leg from supply to return with circuit setter on supply line and ball valve on bypass line, SFA #E6483-1 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229 Phone: 800.877.9222 Fax: 614.841.6022 Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco (PD) Italy Phone: +39 049 9719 111 Fax: +39 049 5841 257 Liebert Web Site—http://www.liebert.com 23F, Allied Kajima Bldg. 138 Gloucester Road Wanchai Hong Kong Phone: +852 2 572 2201 Fax: +852 2 831 0114 ©2004 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. ®Liebert and the Liebert logo are registered trademarks of Liebert Corporation. All names referred to are trademarks or regisered trademarks of their respective owners. SL-16558 (2/04) Indoor/Outdoor Process Chiller Designed for GE Signa or 1.5T Excite 2