Keeping Business in Business • • • • • • • • Indoor/Outdoor Process Fluid Chiller Designed for Siemens Magnetom Impact Dedicated, equipment-matched cooling supplies the proper temperature and water flow year round. Factory-tested, piped, wired and charged for hassle-free startup and operation. Clean, non-ferrous cooling loop, required for sensitive medical equipment. Local service and parts for quick and knowledgeable maintenance and service. Optional switch-over to alternate water source provides redundant, continuous operation. Optional remote monitoring systems keep you informed of chiller operation. ETL/CSA certified. ISO 9001 certified company. Magnetom Impact Specifications Fluid Specified Water/Glycol Max Heat Dissipation—BTUH (kW) 27,325 (8) Fluid Temperature Range °F (°C) 45-65 (7-18) Temperature Gradient N/A Fluid Flow Rate—GPM (l/m) 1.3 (4.9) Fluid Pressure Drop—PSI (kPa) 7 (48.3) Process Fluid Chiller Specifications Model Number PS036A PS036A PS036A Fluid Circulated Water Ethylene Glycol Propylene Glycol Net Cooling Capacity—BTUH (kW) 27,800 (8.1) 27,900 (8.2) 27,400 (8.0) Leaving Fluid Temperature—°F (°C) 47 (8.3) 53 (11.7) 56 (13.3) Fluid Flow Rate—GPM (l/m) 1.3 (4.9) 1.5 (5.7) 1.6 (6.1) Magnetom Impact Pressure Drop—PSI (kPa) 7 (48.3) 13.5 (93.1) 16.7 (115.1) Chiller Pressure Drop—PSI (kPa) 1.5 (10.3) 2.2 (15.2) 2.6 (17.9) Pump Total Head—PSI (kPa) 41.0 (283) 41.0 (283) 41.0 (283) 3/4 (0.6) 3/4 (0.6) 3/4 (0.6) Pump—HP (kW) Indoor/Outdoor Process Fluid Chiller Designed for Siemens Magnetom Impact 1 A AIRFLOW IN B D AIRFLOW OUT C* SHADED AREAS INDICATE A RECOMMENDED CLEARANCE FOR COMPONENT REMOVAL, ACCESS, AND AIR FLOW. OPTIONAL REFRIGERANT PRESSURE GAUGES SHADED AREAS INDICATE A RECOMMENDED CLEARANCE FOR COMPONENT REMOVAL, ACCESS, AND AIR FLOW. 2" 18" (457mm) (51mm) 36" (914mm) 36" (914mm) I I 1" NPT FEMALE TYPICAL H UNIT DIMENSIONAL DATA 1" MAX. (25mm) H 36" (914mm) 1" MAX. (25mm) 3/4" NPT FEMALE UNIT DIMENSIONAL DATA G Model No. A-Depth in. (mm) B-Width in. (mm) C-Height in. (mm) Weight lbs. (kg) Voltage (60 Hz) Voltage (50 Hz) PS036A 36 (914) 48 (1219) 32.5 (825) 515 (233) 460, 3-phase 208/230, 1- or 3-phase 400, 3-phase 200/230, 1- or 3-phase Standard Features Accessories • • • • • • • • • • • • • • • • • • • Indoor/outdoor cabinet Hermetic compressor Refrigerant dehydrator Expansion valve Refrigerant receiver Stainless steel expansion tank Pressure relief valve Hot gas bypass valve capacity control Stainless steel pump Optional Features Enviro-source emergency bypass Fluid pressure gauge Check valve Dial thermometer Relief valve Circuit setter Ball valve High temperature thermostat Low flow switch Liebert RCM4 remote alarm monitor • Refrigerant gauges and expansion tank heater 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229 Phone: 800.877.9222 Fax: 614.841.6022 Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco Italy Phone: 39.049.9719.111 Fax: 39.049.5841257 Liebert Web Site—http:www.liebert.com 23/F Allied Kajima Bldg. 138 Gloucester Road Wanchai Hong Kong Phone: 852.2.572.2201 Fax: 852.2.572.1182 ©2000 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. ®Liebert and the Liebert logo are registered trademarks of Liebert Corporation. All names referred to are trademarks or regisered trademarks of their respective owners. SL-16562 (07/00) Indoor/Outdoor Process Fluid Chiller Designed for Siemens Magnetom Impact 2