View PDF

FINAL PRODUCT/PROCESS CHANGE NOTIFICATION #20401
Generic Copy
Issue Date: 18-Mar-2014
TITLE: Qualification of ON Semiconductor Vietnam for Assembly/Test of SMA (Zener, Power
Schottky and Ultrafast Rectifiers).
PROPOSED FIRST SHIP DATE: 18-Jun-2014
AFFECTED CHANGE CATEGORY(S): ON Semiconductor Assembly Location
FOR ANY QUESTIONS CONCERNING THIS NOTIFICATION:
Contact your local ON Semiconductor sales office or Raja Roziah Raja Rahmat
<[email protected]> for Power Schottky and Ultrafast Rectifiers or Syahrul
Samsuddin @ A.Rahim <[email protected]> for Zener.
SAMPLES: Contact your local ON Semiconductor Sales Office
ADDITIONAL RELIABILITY DATA: Available
Contact
your
local
ON
Semiconductor
<[email protected]>
Sales
Office
or
Chean
Ching
Sim
NOTIFICATION TYPE:
Final Product/Process Change Notification (FPCN)
Final change notification sent to customers. FPCN are issued at least 90 days prior to
implementation of the change.
ON Semiconductor will consider this change approved unless specific conditions of acceptance are
provided in writing within 30days of receipt of this notice. To do so, contact <[email protected]>.
DESCRIPTION AND PURPOSE:
This FPCN announces the planned capacity expansion of ON Semiconductor’s assembly and test
operations of SMA discrete packaged products, currently built at ON Semiconductor Seremban
facility to ON Semiconductor Vietnam (OSV).
Upon the expiration of this FPCN, Zener, Power Schottky and Ultrafast Rectifiers devices may be
processed at either location. These products have been qualified to commodity/commercial
requirements. These products will continue being Pb-free, Halide free and RoHS compliant. As part
of this planned capacity expansion, ON Semiconductor has qualified a more automated
manufacturing process. As a result of this automated process, die polarity orientation for Zener
devices could occur cathode or anode to leadframe. Final product polarity will be determined at
100% final electrical test and cathode polarity band will be laser marked at that time on the package.
Issue Date: 18-Mar-2014
Rev. 06-Jan-2010
Page 1 of 4
FINAL PRODUCT/PROCESS CHANGE NOTIFICATION #20401
RELIABILITY DATA SUMMARY:
1SMA5945BT3G
Test
Autoclave
H3TRB
HTRB
HTSL
IOL
RSH
Solderability
TC
Conditions
Ta =121°C, RH=100%, Pressure=15Psig
Ta=85°C, 85% RH, 80% rated or 100V max
Ta=150°C, Tj Max=150°C, Tj=150°C
Ta=150°C
Ta=25°C, delta Tj=100°C On/off = 2 min
260°C Immersion
Steam Aging=8hrs
Ta=-65/150° C
Interval
96hrs
504hrs
504hrs
504hrs
7500cyc
8 hrs
1000cyc
Result
0/252
0/252
0/252
0/252
0/252
0/90
0/45
0/252
1SMA54AT3G
Test
Autoclave
H3TRB
HTRB
HTSL
IOL
RSH
Solderability
TC
Conditions
Ta =121°C, RH=100%, Pressure=15Psig
Ta=85°C, 85% RH, 80% rated or 100V max
Ta=150°C, Tj Max=150°C, Tj=150°C
Ta=150°C
Ta=25°C, delta Tj=100°C On/off = 2 min
260°C Immersion
Steam Aging=8hrs
Ta=-65/150° C
Interval
96hrs
504hrs
504hrs
504hrs
7500cyc
8 hrs
1000cyc
Result
0/252
0/252
0/252
0/252
0/252
0/90
0/45
0/252
1SMA60CAT3G
Test
Autoclave
H3TRB
HTRB
HTSL
IOL
RSH
Solderability
TC
Conditions
Ta =121°C, RH=100%, Pressure=15Psig
Ta=85°C, 85% RH, 80% rated or 100V max
Ta=150°C, Tj Max=150°C, Tj=150°C
Ta=150°C
Ta=25°C, delta Tj=100°C On/off = 2 min
260°C Immersion
Steam Aging=8hrs
Ta=-65/150° C
Interval
96hrs
504hrs
504hrs
504hrs
7500cyc
8 hrs
1000cyc
Result
0/252
0/252
0/252
0/252
0/252
0/90
0/45
0/252
MBRA2H100T3G
Test
Autoclave
H3TRB
HTRB
HTSL
IOL
RSH
Solderability
TC
Conditions
Ta =121°C, RH=100%, Pressure=15Psig
Ta=85°C, 85% RH, 80% rated or 100V max
Ta=150°C, Tj Max=150°C, Tj=150°C
Ta=150°C
Ta=25°C, delta Tj=100°C On/off = 2 min
260°C Immersion
Steam Aging=8hrs
Ta=-65/150° C
Issue Date: 18-Mar-2014
Rev. 06-Jan-2010
Interval
96hrs
504hrs
504hrs
504hrs
7500cyc
8 hrs
1000cyc
Result
0/252
0/252
0/252
0/252
0/252
0/90
0/45
0/252
Page 2 of 4
FINAL PRODUCT/PROCESS CHANGE NOTIFICATION #20401
MURA260T3G
Test
Autoclave
H3TRB
HTRB
HTSL
IOL
RSH
Solderability
TC
Conditions
Ta =121°C, RH=100%, Pressure=15Psig
Ta=85°C, 85% RH, 80% rated or 100V max
Ta=150°C, Tj Max=150°C, Tj=150°C
Ta=150°C
Ta=25°C, delta Tj=100°C On/off = 2 min
260°C Immersion
Steam Aging=8hrs
Ta=-65/150° C
Interval
96hrs
504hrs
504hrs
504hrs
7500cyc
8 hrs
1000cyc
Result
0/252
0/252
0/252
0/252
0/252
0/90
0/45
0/252
ELECTRICAL CHARACTERISTIC SUMMARY:
Product performance meets data sheet specification.
CHANGED PART IDENTIFICATION:
Devices sourced from OSV in Vietnam will carry the site code “VN” at the bottom of the package.
List of affected General Parts:
1SMA5913BT3G
1SMA5916BT3G
1SMA5919BT3G
1SMA5922BT3G
1SMA5925BT3G
1SMA5928BT3G
1SMA5931BT3G
1SMA5934BT3G
1SMA5937BT3G
1SMA5940BT3G
1SMA5943BT3G
1SMA5914BT3G
1SMA5917BT3G
1SMA5920BT3G
1SMA5923BT3G
1SMA5926BT3G
1SMA5929BT3G
1SMA5932BT3G
1SMA5935BT3G
1SMA5938BT3G
1SMA5941BT3G
1SMA5945BT3G
1SMA5915BT3G
1SMA5918BT3G
1SMA5921BT3G
1SMA5924BT3G
1SMA5927BT3G
1SMA5930BT3G
1SMA5933BT3G
1SMA5936BT3G
1SMA5939BT3G
1SMA5942BT3G
1SMA10AT3G
1SMA11AT3G
1SMA14AT3G
1SMA17AT3G
1SMA22AT3G
1SMA28AT3G
1SMA36AT3G
1SMA12AT3G
1SMA15AT3G
1SMA18AT3G
1SMA24AT3G
1SMA30AT3G
1SMA40AT3G
1SMA13AT3G
1SMA16AT3G
1SMA20AT3G
1SMA26AT3G
1SMA33AT3G
1SMA43AT3G
1SMA45AT3G
1SMA54AT3G
1SMA6.5AT3G
1SMA8.5AT3G
BZG03C15G
NS6A5.0AT3G
1SMA48AT3G
1SMA58AT3G
1SMA70AT3G
1SMA9.0AT3G
NS6A12AT3G
NSA5.0AT3G
1SMA5.0AT3G
1SMA6.0AT3G
1SMA8.0AT3G
BZG03C150G
NS6A13AT3G
1SMA10CAT3G
Issue Date: 18-Mar-2014
Rev. 06-Jan-2010
Page 3 of 4
FINAL PRODUCT/PROCESS CHANGE NOTIFICATION #20401
NS6A13AT3H
1SMA12CAT3G
1SMA16CAT3G
1SMA24CAT3G
1SMA30CAT3G
1SMA40CAT3G
1SMA60CAT3G
MBRA120ET3G
MBRA160T3G
MBRA210ET3H
MBRA2H100T3G
SS16T3G
MURA115T3G
MURA130T3G
MURA160T3H
MURA215T3G
MURA240T3G
NS6A5.0AT3H
1SMA13CAT3G
1SMA18CAT3G
1SMA26CAT3G
1SMA33CAT3G
1SMA48CAT3G
1SMA70CAT3G
MBRA130LT3G
MBRA1H100T3G
MBRA210LT3G
MBRA320T3G
MURA105T3G
MURA120T3G
MURA140T3G
MURA205T3G
MURA220T3G
MURA260T3G
Issue Date: 18-Mar-2014
1SMA15CAT3G
1SMA20CAT3G
1SMA28CAT3G
1SMA36CAT3G
1SMA58CAT3G
1SMA78CAT3G
MBRA140T3G
MBRA210ET3G
MBRA210LT3H
MBRA340T3G
MURA110T3G
MURA120T3H
MURA160T3G
MURA210T3G
MURA230T3G
Rev. 06-Jan-2010
Page 4 of 4