MPI Intelligent PDU Data Sheet

MPI
Intelligent PDU
The MPI Intelligent PDU delivers the most accurate, real-time monitoring of connected equipment.
With metering and monitoring features, together with the capability for users to set custom
thresholds, the MPI allows users to optimize their electrical infrastructure without the risk of downtime
caused by overloaded circuits.
Features:
„„
Single-phase input that supports strip/
branch -level metering or strip/branch -level
metering and outlet switching
„„
Measures and monitors voltage, current
(branch), frequency, power (kW), energy
consumption (kWh) and power factor.
„„
Threshold/alert capabilities provide
preemptive notification of any impending
overload issues before they occur
„„
Supports external environmental sensors
such as temperature, humidity, cabinet door
status, water leakage and infrared motion
sensors for notification of any impending
environmental issues
„„
LED display and a built-in browser interface
for local and remote access with real-time
data
„„
1U Metered & Switched PDU
Management Panel
Outlet
0U Metered & Switched PDU (16 and 24 ways)
Remote switching capability to power on/off
outlets (only for Switched PDU)
„„
Power sequential startup and reboot on
outlets groups defined by user (only for
Switched PDU) – Protects plugged-in devices
from sudden power surge
„„
Onboard data log for individual PDU with up
to 10,000 empirical data and alarm logs
„„
Highly compatible with multiple
management software platform including
RDU-A G2 and RDU-M
„„
IP and Serial Interface Options – Options
to install by connecting directly to the
network or save IP connections by using
the serial interface to connect directly to
RDU appliances already connected to the
network
„„
Supports horizontal and vertical models for
a variety of rack configurations in branch
and remote offices
Management Panel
Breaker
Outlet
MPI PDU Management Panel
Management Panel provides the network communication,
system software upgrading, external sensor integration and
onboard LED display.
Supports external environmental sensors such as temperature,
humidity, rack door status, water leakage and infrared motion
detective in chain.
Management Software
ETH
Ethernet
Port
Communication to the management
software
Up to 8 sensors per PDU sensor port:
„„Temperature sensor or
„„Temperature & Humidity sensor x 4
Sensor
Sensor
Port
„„Rack Door Status x 2
„„Water Leakage Detection x 1
„„Infrared Motion Detection x 1
„„4DIF x 1 as mandatory for connection to
Door Status / Water Leakage Detective /
Infrared Motion Detective
Link
Link Port
Direct connection to the COM port
of RDU-A
Console
Console
Port
System Maintenance
Current
Indicator
Green light lasting: Data displayed on
the LED and no real-time alarm
Environmental Sensor Chain
Red light lasting: Data displayed on the
LED and with real-time alarm
Voltage
Indicator
Red light spackle: Data not displayed on
the LED but with real-time alarm
Link
Indicator
Green light lasting: Data displayed on
the LED
IP
IP address
Indicator
Green light lasting: Data displayed on
the LED
A/V
Current /
Voltage
Value of the data (Current/Voltage)
displayed
q
Cycling
Display
Switch the data display of Current/
Voltage/IP/ID and operation on ID
address setting
É
Confirm
Start / End operation on ID address
setting
Reset
Reset
Push with duration > 5s, Restore the
password of admin as default setting
Door Status
4DIF Sensor
Door Status
Temperature Sensor
Temperature &
Humidity Sensor
Infrared Motion
Detector
Water Leakage
Detector
4DI with Phoenix
Contact Sensor
4DIF with RJ45
Contact Sensor
Specifications
Plug
No.
Type
1
C20
3
Fixed
16A
L - Line(Red)
N - Line (Blue)
PE - (Yellow-Green)
Outlet
1
Type
Appearance
IEC C13
Frequency:
45-65Hz
Voltage:
±1%(200~240Vac); ±2% (other range)
Current:
±0.2A
Up to 8 sensors per PDU sensor port:
Note: The dimensions of IEC60309 2P + PE 16A / IEC60309 2P + PE 32A plugs are different
No.
100 ~ 240Vac/ Single Phase
External Environmental Sensors:
32A
16A or
32A
Input Voltage:
Metering Accuracy:
16A
IEC60309 2P
+ PE16A
IEC60309 2P
+ PE32A
2
Rate
Power Supply
Appearance Current
Interface for PDU
Rate Current
10A
Temperature sensor or Temperature & Humidity sensor x 4
4DIFx 1 (required for DI sensors)
Rack Door Status x 2
Water Leakage Detection x 1
Infrared Motion Detection x 1
External Power
Required:
No
Port Type:
RJ45
Cable Type:
Standard CAT-5 Patch Cable
Maximal cable distance
from end to end:
100m (Between the PDU to the last
sensor in chain)
Physical Dimensions:
2
IEC C19
Note: The dimensions of GB10A / 16A outlets are different.
MPI PDU Management Integration
with RDU-M
Management
Software
Integration
(RDU-M)
Remote On/
Off Control
On Outlets
Alarms and
Monitoring
Energy
Consumption
Analysis
16A
Type
Dimension (W x H x D, mm)
Weight
1U 8 ways PDU
440 x 43.5 x 260
<=5KG
0U 16 ways PDU
56 x 1422 x 50
<=5.5KG
0U 24 ways PDU
56 x 1780 x 50
<=6.0KG
Working Environmental:
Operating Temperature: -20°C to 55°C
Storage Temperature:
-40°C ~ 70°C
Networking Connection:
Number:
1
Type:
1 - 10/100 Ethernet
Accessories Included:
Rack-mount kit, tool less-mounting
hardware with vertical models
Communications
options supported:
Browser(HTTP/HTTPS),
Serial(ModBus) or IP(SNMP/Private
protocol) (using RDU appliance)
Certification
CE
According to European Low Voltage
Directive 2006/95/EC, European Directive
for Electromagnetic Compatibility
2004/108/EC and European RoHS directive
2011/65/EU
Standards
Safety standard:
EN 60950-1:2006+A11:2009+A1:2010+A
12:2011+A2:2013
EMC standard:
EN 300 386 V1.6.1:2012
MPI
Intelligent PDU
Model Number
Rate
Current
Qty of
Outlet
Type of
Outlet
Type of Plug
Qty of
Breaker
Rate Current of
Breaker
MP-DHCNHA08N00X
16A
8
C13
C20
2
10A
MP-DHENCA04B04X
32A
4
C13
4
C19
4
C13
4
C19
2
17A
MP-DHANCA04B04X
1U Metered PDU
32A
8
C13
IEC60309
32A
8
C13
Fixed
MP-DHENCB08N00X
32A
8
C19
IEC60309
MP-DHANCB08N00X
32A
8
C19
Fixed
6
C13
2
C19
MP-EHCNHA08N00X
0U Metered PDU
MP-EHENCA04B04X
32A
MP-EHANCA04B04X
32A
8
C13
4
C13
4
C19
4
C13
4
C19
IEC60309
C20
32A
8
C13
IEC60309
32A
8
C13
Fixed
MP-EHENCB08N00X
32A
8
C19
IEC60309
MP-EHANCB08N00X
32A
8
C19
Fixed
MP-EHENCA06B02X
32A
6
C13
2
C19
MP-DVENCA16N00X
32A
16
C13
MP-DVENCA12B04X
32A
12
C13
4
C19
MP-DVCNHA16N00X
16A
32A
MP-DVANCA18B06X
32A
MP-EVENCA16N00X
32A
MP-EVENCA12B04X
32A
MP-EVCNHA16N00X
16A
MP-EVENCA18B06X
32A
MP-EVANCA18B06X
32A
C13
18
C13
6
C19
18
C13
6
C19
16
C13
12
C13
4
C19
16
C13
18
C13
6
C19
18
C13
6
C19
2
10A
2
17A
Fixed
MP-EHENCA08N00X
16
Horizontal
mounting
IEC60309
MP-EHANCA08N00X
MP-DVENCA18B06X
0U Switched PDU
16A
440.0 × 43.5 ×
260.0
Power Cord
Length
Fixed
MP-DHENCA08N00X
32A
Installation in
Racks
IEC60309
MP-DHANCA08N00X
MP-DHENCA06B02X
1U Switched PDU
32A
Dimension
(W x H x D, mm)
3 meters
IEC60309
IEC60309
IEC60309
C20
2
17A
2
10A
2
17A
2
17A
2
10A
2
17A
56.0 × 1422.0 ×
50.0
0U vertical
mounting
56.0 × 1780.0 ×
50.0
0U vertical
mounting
56.0 × 1422.0 ×
50.0
0U vertical
mounting
56.0 × 1780.0 ×
50.0
0U vertical
mounting
IEC60309
Fixed
IEC60309
IEC60309
C20
IEC60309
Fixed
[email protected]
www.EmersonNetworkPower.Asia
While every precaution has been taken to ensure accuracy and completeness herein, Emerson Network Power assumes no responsibility, and disclaims all liability, for damages
resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice.
Emerson Network Power and the Emerson Network Power logo are trademarks of Emerson Electric Co. or one of its affiliated companies. All other names and logos referred to
are trade names, trademarks, or registered trademarks of their respective owners. ©2015 Emerson Electric Co. AP15ENT-MPIIntelligentPDUv4-DS