typ T11-811

T11-811
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Circuit Breaker for Equipment thermal, Drop-in type, Reset type, Quick connect terminals
Description
-Drop-in type
-Thermal circuit breaker
-1‑pole
-Reset type
-Quick connect terminals 6.3 x 0.8 mm
Unique Selling Proposition
Applications
-Power tools
-Household Equipment
-Power supplies and chargers
-Industrial appliances
Weblinks
pdf-datasheet, html-datasheet, General Product Information,
Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, REACH,
SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for
product, Product News
-Compact design
-Positively trip-free release
-Available with cover
-Different mounting possibilities
Standards
- IEC 60934
- UL 1077
- CSA C22.2 No. 235
- GB 17701
Technical Data
Rated Voltage AC
Rated Voltage DC
Rated current range AC
Conditional short circuit capacity
Short circuit capacity Icn
␣
Degree of Protection
Dielectric Strength
Insulation resistance
Endurance typical
Endurance minimum
240 V; 50/60 Hz
48 V
0.05 - 16 A
IEC: Inc, PC1, AC 240 V: 2 kA at In < 6.5 A/240 VAC : 8 x In at In ≥ 6.5 A/240 VAC : 96 A from front side IP 40 acc. to IEC 60529
50 Hz: > 1.5 kV
Impulse 1.2/50 μs: > 2.5 kV
500 VDC > 100 MΩ
2 x Ir: 500 switching cycles
Reset type AC : 2 x Ir , cos φ 0.6 : DC : 2 x Ir , L/R = 2 - 3 ms : 50 switching cycles
Overload
␣
Ambient temperature
Vibration Resistance
Shock Resistance
Tripping Type
Actuation type
Weight
IEC: min. 40 trips
@ 6 x Ir, cos φ 0.6
UL / CSA: min. 50 trips
@ 1.5 x Ir, cos φ 0.75
-5 °C to 60 °C
± 1.5 mm @ 10 - 60 Hz
acc. to IEC 60068-2-6, test Fc
5 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Fc
100 G / 6 ms
acc. to IEC 60068-2-27, test Ea
Thermal Reset type ca. 10 g
Circuit Breakers
1
T11-811
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Dimension
T11-811 <7,5A
1
Ø4
10
T11-811N
3
11
9.2
44
48.2
19
34.5
4
9.0
11.5
9
T11-811 >7,5 A
15.2
6.3
Diagrams
Rated current ≤7,5 A
2
Shunt terminal T11-...N ≤6,5 A
Rated current >7,5 A
1
1
1
2
3
2
Circuit Breakers
3
2
T11-811
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Typical internal resistance
Rated Current [A]
Internal Resistance [Ω]
0.05
380.000
0.50
5.200
1.00
1.350
2.00
0.300
3.00
0.130
4.00
0.080
5.00
0.040
6.00
0.040
7.00
0.020
8.00
0.012
9.00
0.012
10.00
0.011
11.00
0.0095
12.00
0.0095
13.00
0.0085
14.00
0.0085
15.00
0.0075
16.00
0.0075
Time-Current-Curves
[ min ] [ sec]
10`000
< 6,5 A
> 6,5 A
60
30
20
10
2`000
1`000
500
5
Time in Seconds
200
100
1
50
20
10
5
2
1
0,5
0,3
0,2
0,1
1,05 1,35
2
3
4
5
8
10
Multiple of Rated Current In
Reference Temperature +23°
Circuit Breakers
3
T11-811
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Effect of ambient temperature
The units are calibrated for an ambient temperature of +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from
the table below:
Ambient temperature [°C]
Correction factor
-5
0.87
0
0.90
+10
0.95
+23
1.00
+30
1.04
+40
1.10
+50
1.15
+60
1.20
Example: Rated current = 5 A; Environmental temperature = 40 °C; --> Correction factor =
1.1; Resulting current = 5.5 A --> Fount to next higher rated current: 6 A
Config. Code
T11|-|1|2|3|A|B|-|1.23|
The characters are placeholders for the correspondingly keys of selections from the key tables.
T11|-| 1 |2|3|A|B|-|1.23| = Mounting
Mounting
Rated current
Configuration
key
Drop-in type
8
T11|-|1| 2 |3|A|B|-|1.23| = Actuation type
Actuation type
Configuration
key
Reset type
1
Quick connect terminal 6.3x0.8mm
Shunt terminal
0.6
0.7 A
0.7
0.8 A
0.8
0.9 A
0.9
1.0
1
1.2
1.3
Configuration
key
1.4 A
1.4
1.5 A
1.5
1
1.6 A
1.6
1.7 A
1.7
1.8 A
1.8
1.9 A
1.9
Configuration
key
2.0 A
2
2.1 A
2.1
N
2.3 A
2.3
2.5 A
2.5
2.8 A
2.8
R
T11|-|1|2|3|A|B|-| 1.23 | = Rated current
Rated current
0.5
0.6 A
1.3 A
Configuration
key
Setting indication
0.4
0.5 A
1.2 A
T11|-|1|2|3|A| B |-|1.23| = Setting indication
Setting indication
0.3
0.4 A
1.1
T11|-|1|2|3| A |B|-|1.23| = Shunt terminal
Shunt terminal
0.3 A
1.1 A
T11|-|1|2| 3 |A|B|-|1.23| = Terminal
Terminal
Configuration
key
Configuration
key
3.0 A
3
3.3 A
3.3
3.5 A
3.5
4.0 A
4
4.5 A
4.5
5.0 A
5
5.5 A
5.5
6.0
6
0.05 A
0.05
6.5 A
0.1 A
0.1
7.0 A
7
0.15 A
0.15
7.5 A
7.5
0.2 A
0.2
8.0 A
8
8.5 A
8.5
Other rated currents on request
Other rated currents on request
4
Circuit Breakers
6.5
T11-811
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Rated current
Configuration
key
Rated current
Configuration
key
9.0 A
9
13.0 A
13
9.5 A
9.5
14.0 A
14
10.0 A
10
15.0 A
15
11.0 A
11
16.0 A
16
12.0 A
12
Other rated currents on request
Other rated currents on request
Variants
Rated current
Construction variants
Config. Code
Order Number
3.0 A
T11-811-3
4400.0112
5.0 A
T11-811-5
4400.0114
5.5 A
T11-811-5.5
4400.0120
2.5 A
T11-811-2.5
4400.0178
T11-811-6
4400.0179
Shunt terminal
6.0
Setting indication
Availability for all products can be searched real-time:http://www.schurter.com/Stock-Check/StockCheck-SCHURTER
Packaging Unit 100 Pcs Accessories
Description
T-Linie Zubehör
Accessories to T-Line
06.06.2016
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
Circuit Breakers