BZG05C... Vishay Telefunken Silicon Z–Diodes Features D D D D D Glass passivated junction High reliability Voltage range 3.3V to 100V Fits onto 5 mm SMD footpads Wave and reflow solderable 15 811 Applications Voltage stabilization Absolute Maximum Ratings Tj = 25_C Parameter Power dissipation Non repetitive peak surge power dissipation Junction temperature Storage temperature range Test Conditions RthJA<30K/W, Tamb=60°C RthJA<100K/W, Tamb=25°C tp=100ms sq.pulse, Tj=25°C prior to surge Type Symbol PV PV PZSM Value 3 1.25 60 Unit W W W Tj Tstg 150 –65...+150 °C °C Maximum Thermal Resistance Tj = 25_C Parameter Test Conditions Junction lead Junction ambient mounted on epoxy–glass hard tissue, Fig. 1a mounted on epoxy–glass hard tissue, Fig. 1b mounted on Al–oxid–ceramic (Al2O3), Fig. 1b Symbol RthJL RthJA RthJA RthJA Value 30 150 125 100 Unit K/W K/W K/W K/W Electrical Characteristics Tj = 25_C Parameter Forward voltage Document Number 85595 Rev. 6, 01-Apr-99 Test Conditions IF=0.2A Type Symbol VF Min Typ Max 1.2 Unit V www.vishay.de • FaxBack +1-408-970-5600 1 (4) BZG05C... Vishay Telefunken Type BZG05C... 3V3 3V6 3V9 4V3 4V7 5V1 5V6 6V2 6V8 7V5 8V2 9V1 10 11 12 13 15 16 18 20 22 24 27 30 33 36 39 43 47 51 56 62 68 75 82 91 100 VZnom V 3.3 3.6 3.9 4.3 4.7 5.1 5.6 6.2 6.8 7.5 8.2 9.1 10 11 12 13 15 16 18 20 22 24 27 30 33 36 39 43 47 51 56 62 68 75 82 91 100 IZT mA 80 60 60 50 45 45 45 35 35 35 25 25 25 20 20 20 15 15 15 10 10 10 8 8 8 8 6 6 4 4 4 4 4 4 2.7 2.7 2.7 for VZT and V 3.1 to 3.5 3.4 to 3.8 3.7 to 4.1 4.0 to 4.6 4.4 to 5.0 4.8 to 5.4 5.2 to 6.0 5.8 to 6.6 6.4 to 7.2 7.0 to 7.9 7.7 to 8.7 8.5 to 9.6 9.4 to 10.6 10.4 to 11.6 11.4 to 12.7 12.4 to 14.1 13.8 to 15.6 15.3 to 17.1 16.8 to 19.1 18.8 to 21.2 20.8 to 23.3 22.8 to 25.6 25.1 to 28.9 28 to 32 31 to 35 34 to 38 37 to 41 40 to 46 44 to 50 48 to 54 52 to 60 58 to 66 64 to 72 70 to 79 77 to 87 85 to 96 95 to 105 www.vishay.de • FaxBack +1-408-970-5600 2 (4) rzjT W < 20 < 20 < 15 < 13 < 13 < 10 <7 <4 < 3.5 <3 <5 <5 <7 <8 <9 < 10 < 15 < 15 < 20 < 24 < 25 < 25 < 30 < 30 < 35 < 40 < 50 < 50 < 90 < 115 < 120 < 125 < 130 < 135 < 200 < 250 < 350 rzjk W at < 400 < 500 < 500 < 500 < 600 < 500 < 400 < 300 < 300 < 200 < 200 < 200 < 200 < 300 < 350 < 400 < 500 < 500 < 500 < 600 < 600 < 600 < 750 < 1000 < 1000 < 1000 < 1000 < 1000 < 1500 < 1500 < 2000 < 2000 < 2000 < 2000 < 3000 < 3000 < 3000 IZK mA 1 1 1 1 1 1 1 1 1 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 IR mA < 40 < 20 < 10 <3 <3 <1 <1 <1 <1 <1 <1 <1 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 0.5 0.5 0.5 at VR V 1 1 1 1 1 1.5 2 3 4 4.5 6.2 6.8 7 8.2 9.1 10 11 12 13 15 16 18 20 22 24 27 30 33 36 39 43 47 51 56 62 68 75 TKVZ %/K –0.08 to –0.05 –0.08 to –0.05 –0.07 to –0.02 –0.07 to –0.01 –0.03 to +0.04 –0.01 to +0.04 0 to +0.045 +0.01 to +0.055 +0.015 to +0.06 +0.02 to +0.065 0.03 to 0.07 0.035 to 0.075 0.04 to 0.08 0.045 to 0.08 0.045 to 0.085 0.05 to 0.085 0.055 to 0.09 0.055 to 0.09 0.06 to 0.09 0.06 to 0.09 0.06 to 0.095 0.06 to 0.095 0.06 to 0.095 0.06 to 0.095 0.06 to 0.095 0.06 to 0.095 0.06 to 0.095 0.06 to 0.095 0.06 to 0.095 0.06 to 0.095 0.06 to 0.095 0.06 to 0.095 0.06 to 0.095 0.06 to 0.095 0.06 to 0.095 0.06 to 0.095 0.06 to 0.095 Document Number 85595 Rev. 6, 01-Apr-99 BZG05C... Vishay Telefunken Characteristics (Tj = 25_C unless otherwise specified) a) b) 5.0 2.0 2.0 1.5 2.6 10.0 2.4 2.2 2.4 7.0 1.0 25.0 94 9314 25.0 94 9313 Figure 1. Boards for RthJA definition (copper overlay 35m) Figure 2. Recommended foot pads (in mm) Dimensions in mm 14275 Document Number 85595 Rev. 6, 01-Apr-99 www.vishay.de • FaxBack +1-408-970-5600 3 (4) BZG05C... Vishay Telefunken Ozone Depleting Substances Policy Statement It is the policy of Vishay Semiconductor GmbH to 1. Meet all present and future national and international statutory requirements. 2. Regularly and continuously improve the performance of our products, processes, distribution and operating systems with respect to their impact on the health and safety of our employees and the public, as well as their impact on the environment. It is particular concern to control or eliminate releases of those substances into the atmosphere which are known as ozone depleting substances ( ODSs ). The Montreal Protocol ( 1987 ) and its London Amendments ( 1990 ) intend to severely restrict the use of ODSs and forbid their use within the next ten years. Various national and international initiatives are pressing for an earlier ban on these substances. Vishay Semiconductor GmbH has been able to use its policy of continuous improvements to eliminate the use of ODSs listed in the following documents. 1. Annex A, B and list of transitional substances of the Montreal Protocol and the London Amendments respectively 2 . Class I and II ozone depleting substances in the Clean Air Act Amendments of 1990 by the Environmental Protection Agency ( EPA ) in the USA 3. Council Decision 88/540/EEC and 91/690/EEC Annex A, B and C ( transitional substances ) respectively. Vishay Semiconductor GmbH can certify that our semiconductors are not manufactured with ozone depleting substances and do not contain such substances. We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications. All operating parameters must be validated for each customer application by the customer. Should the buyer use Vishay-Telefunken products for any unintended or unauthorized application, the buyer shall indemnify Vishay-Telefunken against all claims, costs, damages, and expenses, arising out of, directly or indirectly, any claim of personal damage, injury or death associated with such unintended or unauthorized use. Vishay Semiconductor GmbH, P.O.B. 3535, D-74025 Heilbronn, Germany Telephone: 49 ( 0 ) 7131 67 2831, Fax number: 49 ( 0 ) 7131 67 2423 www.vishay.de • FaxBack +1-408-970-5600 4 (4) Document Number 85595 Rev. 6, 01-Apr-99