INFINEON BAR67-04

BAR67...
Silicon PIN Diode
• For low loss RF switches and attenuators
• Very low capacitance at zero volt reverse
bias at frequencies above 1 GHz (typ. 0.25 pF)
• Low forward resistance (typ. 1.5 Ω @ 5mA)
• Low harmonics
• Pb-free (RoHS compliant) package 1)
• Qualified according AEC Q101
BAR67-02V
BAR67-04
!
, ,
Type
BAR67-02V
BAR67-04
Package
SC79
SOT23
Configuration
single
series
LS(nH)
0.6
1.8
Marking
T
PMs
Maximum Ratings at TA = 25°C, unless otherwise specified
Parameter
Symbol
Value
Unit
Diode reverse voltage
VR
150
V
Forward current
IF
200
mA
Total power dissipation
Ptot
mW
TS ≤ 118°C, BAR67-02V
250
TS ≤ 25°C, BAR67-04
250
150
Junction temperature
Tj
Operating temperature range
T op
-55 ... 125
Storage temperature
T stg
-55 ... 150
°C
Thermal Resistance
Parameter
Symbol
Junction - soldering point 2)
RthJS
Value
Unit
K/W
BAR67-02V
≤ 115
BAR67-04
≤ 290
1Pb-containing
2For
package may be available upon special request
calculation of RthJA please refer to Application Note Thermal Resistance
1
2007-04-19
BAR67...
Electrical Characteristics at TA = 25°C, unless otherwise specified
Symbol
Values
Parameter
Unit
min.
typ.
max.
150
-
-
V
IR
-
-
20
nA
VF
-
0.95
1.2
V
DC Characteristics
Breakdown voltage
V(BR)
I(BR) = 5 µA
Reverse current
VR = 100 V
Forward voltage
IF = 50 mA
AC Characteristics
Diode capacitance
pF
CT
VR = 5 V, f = 1 MHz
-
0.35
0.55
VR = 0 V, f = 100 MHz
-
0.35
0.9
VR = 0 V, f = 1 GHz
-
0.25
-
VR = 0 V, f = 1.8 GHz
-
0.23
-
Reverse parallel resistance
RP
kΩ
VR = 0 V, f = 100 MHz
-
25
-
VR = 0 V, f = 1 GHz
-
4
-
VR = 0 V, f = 1.8 GHz
-
2.5
-
Forward resistance
Ω
rf
I F = 5 mA, f = 100 MHz
-
1.5
1.8
I F = 10 mA, f = 100 MHz
-
1
-
τ rr
-
700
-
ns
WI
-
13
-
µm
Charge carrier life time
I F = 10 mA, IR = 6 mA, measured at IR = 3 mA,
RL = 100 Ω
I-region width
2
2007-04-19
BAR67...
Diode capacitance CT = ƒ (VR)
f = Parameter
Reverse parallel resistance RP = ƒ(V R)
f = Parameter
10 4
0.5
KOhm
F
10 3
1 MHz
100 MHz
1 GHz
1.8 GHz
0.35
Rp
CT
0.4
10 2
100 MHz
0.3
1 GHz
10 1
0.25
1.8 GHz
0.2
10 0
0.15
0.1
0
5
10
15
20
25
V
30
10 -1
0
40
5
10
15
20
25
V
30
VR
40
VR
Forward resistance rf = ƒ (IF )
f = 100MHz
Forward current IF = ƒ (VF)
TA = Parameter
10 3
10 0
A
Ohm
10 -1
10 2
rf
IF
10 -2
10 1
10 -3
-40 °C
25 °C
85 °C
125 °C
10 -4
10 0
10 -5
10 -1 -2
10
10
-1
10
0
10
1
mA 10
10 -6
0
2
IF
0.2
0.4
0.6
0.8
V
1.2
VF
3
2007-04-19
BAR67...
Forward current IF = ƒ (T S)
Forward current IF = ƒ (T S)
BAR67-02V
BAR67-04
250
220
mA
mA
180
200
160
IF
IF
175
150
140
120
125
100
100
80
75
60
50
40
25
0
0
20
15
30
45
60
90 105 120 °C
75
0
0
150
20
40
60
80
120 °C
100
TS
150
TS
Permissible Puls Load RthJS = ƒ (tp)
Permissible Pulse Load
BAR67-02V
IFmax / I FDC = ƒ (t p)
BAR67-02V
10 3
10 2
IFmax/IFDC
K/W
RthJS
10 2
10
D=0.5
0.2
0.1
0.05
0.02
0.01
0.005
0
1
10 0
10 -1 -6
10
10
-5
10
-4
10
-3
D=0
0.005
0.01
0.02
0.05
0.1
0.2
0.5
10 1
10
-2
s
10
10 0 -6
10
0
tP
10
-5
10
-4
10
-3
10
-2
s
10
0
tP
4
2007-04-19
BAR67...
Permissible Puls Load RthJS = ƒ (tp)
BAR67-04
10 3
K/W
R thJS
10 2
10 1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
D=0
10 0
10 -1 -6
10
10
-5
10
-4
10
-3
10
-2
s
10
0
tP
5
2007-04-19
Package SC79
BAR67...
Package Outline
0.2
M
A
+0.05
0.13 -0.03
0.8 ±0.1
0.2 ±0.05
10˚MAX.
1.6 ±0.1
1
0.3 ±0.05
Cathode
marking
10˚MAX.
1.2 ±0.1
A
2
0.55 ±0.04
0.35
1.35
Foot Print
0.35
Marking Layout (Example)
2005, June
Date code
BAR63-02V
Type code
Cathode marking
Laser marking
Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel
Reel ø180 mm = 8.000 Pieces/Reel (2 mm Pitch)
Reel ø330 mm = 10.000 Pieces/Reel
Cathode
marking
0.4
0.93
0.2
8
1.96
Reel with 2 mm Pitch
2
1.33
Standard
4
Cathode
marking
6
0.66
2007-04-19
BAR67...
Date Code marking for discrete packages with
one digit (SCD80, SC79, SC75 1) ) CES-Code
Month 2 0 03
2 0 04
2005
2006
2 0 07
2008
2009
2010
2011
2012
2 0 13
2014
01
a
p
A
P
a
p
A
P
a
p
A
P
02
b
q
B
Q
b
q
B
Q
b
q
B
Q
03
c
r
C
R
c
r
C
R
c
r
C
R
04
d
s
D
S
d
s
D
S
d
s
D
S
05
e
t
E
T
e
t
E
T
e
t
E
T
06
f
u
F
U
f
u
F
U
f
u
F
U
07
g
v
G
V
g
v
G
V
g
v
G
V
08
h
x
H
X
h
x
H
X
h
x
H
X
09
j
y
J
Y
j
y
J
Y
j
y
J
Y
10
k
z
K
Z
k
z
K
Z
k
z
K
Z
11
l
2
L
4
l
2
L
4
l
2
L
4
12
n
3
N
5
n
3
N
5
n
3
N
5
1) New Marking Layout for SC75, implemented at October 2005.
.
7
2007-04-19
Package SOT23
BAR67...
0.4 +0.1
-0.05
1)
2
0.08...0.1
C
0.95
1.3 ±0.1
1
2.4 ±0.15
3
0.1 MAX.
10˚ MAX.
B
1 ±0.1
10˚ MAX.
2.9 ±0.1
0.15 MIN.
Package Outline
A
5
0...8˚
1.9
0.2
0.25 M B C
M
A
1) Lead width can be 0.6 max. in dambar area
Foot Print
0.8
0.9
1.3
0.9
0.8
1.2
Marking Layout (Example)
Manufacturer
EH s
2005, June
Date code (YM)
Pin 1
BCW66
Type code
Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel
Reel ø330 mm = 10.000 Pieces/Reel
4
0.2
8
2.13
2.65
0.9
Pin 1
1.15
3.15
8
2007-04-19
BAR67...
Edition 2006-02-01
Published by
Infineon Technologies AG
81726 München, Germany
© Infineon Technologies AG 2007.
All Rights Reserved.
Attention please!
The information given in this dokument shall in no event be regarded as a guarantee
of conditions or characteristics (“Beschaffenheitsgarantie”). With respect to any
examples or hints given herein, any typical values stated herein and/or any information
regarding the application of the device, Infineon Technologies hereby disclaims any
and all warranties and liabilities of any kind, including without limitation warranties of
non-infringement of intellectual property rights of any third party.
Information
For further information on technology, delivery terms and conditions and prices
please contact your nearest Infineon Technologies Office ( www.infineon.com).
Warnings
Due to technical requirements components may contain dangerous substances.
For information on the types in question please contact your nearest
Infineon Technologies Office.
Infineon Technologies Components may only be used in life-support devices or
systems with the express written approval of Infineon Technologies, if a failure of
such components can reasonably be expected to cause the failure of that
life-support device or system, or to affect the safety or effectiveness of that
device or system.
Life support devices or systems are intended to be implanted in the human body,
or to support and/or maintain and sustain and/or protect human life. If they fail,
it is reasonable to assume that the health of the user or other persons
may be endangered.
9