BAR67... Silicon PIN Diode • For low loss RF switches and attenuators • Very low capacitance at zero volt reverse bias at frequencies above 1 GHz (typ. 0.25 pF) • Low forward resistance (typ. 1.5 Ω @ 5mA) • Low harmonics • Pb-free (RoHS compliant) package 1) • Qualified according AEC Q101 BAR67-02V BAR67-04 ! , , Type BAR67-02V BAR67-04 Package SC79 SOT23 Configuration single series LS(nH) 0.6 1.8 Marking T PMs Maximum Ratings at TA = 25°C, unless otherwise specified Parameter Symbol Value Unit Diode reverse voltage VR 150 V Forward current IF 200 mA Total power dissipation Ptot mW TS ≤ 118°C, BAR67-02V 250 TS ≤ 25°C, BAR67-04 250 150 Junction temperature Tj Operating temperature range T op -55 ... 125 Storage temperature T stg -55 ... 150 °C Thermal Resistance Parameter Symbol Junction - soldering point 2) RthJS Value Unit K/W BAR67-02V ≤ 115 BAR67-04 ≤ 290 1Pb-containing 2For package may be available upon special request calculation of RthJA please refer to Application Note Thermal Resistance 1 2007-04-19 BAR67... Electrical Characteristics at TA = 25°C, unless otherwise specified Symbol Values Parameter Unit min. typ. max. 150 - - V IR - - 20 nA VF - 0.95 1.2 V DC Characteristics Breakdown voltage V(BR) I(BR) = 5 µA Reverse current VR = 100 V Forward voltage IF = 50 mA AC Characteristics Diode capacitance pF CT VR = 5 V, f = 1 MHz - 0.35 0.55 VR = 0 V, f = 100 MHz - 0.35 0.9 VR = 0 V, f = 1 GHz - 0.25 - VR = 0 V, f = 1.8 GHz - 0.23 - Reverse parallel resistance RP kΩ VR = 0 V, f = 100 MHz - 25 - VR = 0 V, f = 1 GHz - 4 - VR = 0 V, f = 1.8 GHz - 2.5 - Forward resistance Ω rf I F = 5 mA, f = 100 MHz - 1.5 1.8 I F = 10 mA, f = 100 MHz - 1 - τ rr - 700 - ns WI - 13 - µm Charge carrier life time I F = 10 mA, IR = 6 mA, measured at IR = 3 mA, RL = 100 Ω I-region width 2 2007-04-19 BAR67... Diode capacitance CT = ƒ (VR) f = Parameter Reverse parallel resistance RP = ƒ(V R) f = Parameter 10 4 0.5 KOhm F 10 3 1 MHz 100 MHz 1 GHz 1.8 GHz 0.35 Rp CT 0.4 10 2 100 MHz 0.3 1 GHz 10 1 0.25 1.8 GHz 0.2 10 0 0.15 0.1 0 5 10 15 20 25 V 30 10 -1 0 40 5 10 15 20 25 V 30 VR 40 VR Forward resistance rf = ƒ (IF ) f = 100MHz Forward current IF = ƒ (VF) TA = Parameter 10 3 10 0 A Ohm 10 -1 10 2 rf IF 10 -2 10 1 10 -3 -40 °C 25 °C 85 °C 125 °C 10 -4 10 0 10 -5 10 -1 -2 10 10 -1 10 0 10 1 mA 10 10 -6 0 2 IF 0.2 0.4 0.6 0.8 V 1.2 VF 3 2007-04-19 BAR67... Forward current IF = ƒ (T S) Forward current IF = ƒ (T S) BAR67-02V BAR67-04 250 220 mA mA 180 200 160 IF IF 175 150 140 120 125 100 100 80 75 60 50 40 25 0 0 20 15 30 45 60 90 105 120 °C 75 0 0 150 20 40 60 80 120 °C 100 TS 150 TS Permissible Puls Load RthJS = ƒ (tp) Permissible Pulse Load BAR67-02V IFmax / I FDC = ƒ (t p) BAR67-02V 10 3 10 2 IFmax/IFDC K/W RthJS 10 2 10 D=0.5 0.2 0.1 0.05 0.02 0.01 0.005 0 1 10 0 10 -1 -6 10 10 -5 10 -4 10 -3 D=0 0.005 0.01 0.02 0.05 0.1 0.2 0.5 10 1 10 -2 s 10 10 0 -6 10 0 tP 10 -5 10 -4 10 -3 10 -2 s 10 0 tP 4 2007-04-19 BAR67... Permissible Puls Load RthJS = ƒ (tp) BAR67-04 10 3 K/W R thJS 10 2 10 1 0.5 0.2 0.1 0.05 0.02 0.01 0.005 D=0 10 0 10 -1 -6 10 10 -5 10 -4 10 -3 10 -2 s 10 0 tP 5 2007-04-19 Package SC79 BAR67... Package Outline 0.2 M A +0.05 0.13 -0.03 0.8 ±0.1 0.2 ±0.05 10˚MAX. 1.6 ±0.1 1 0.3 ±0.05 Cathode marking 10˚MAX. 1.2 ±0.1 A 2 0.55 ±0.04 0.35 1.35 Foot Print 0.35 Marking Layout (Example) 2005, June Date code BAR63-02V Type code Cathode marking Laser marking Standard Packing Reel ø180 mm = 3.000 Pieces/Reel Reel ø180 mm = 8.000 Pieces/Reel (2 mm Pitch) Reel ø330 mm = 10.000 Pieces/Reel Cathode marking 0.4 0.93 0.2 8 1.96 Reel with 2 mm Pitch 2 1.33 Standard 4 Cathode marking 6 0.66 2007-04-19 BAR67... Date Code marking for discrete packages with one digit (SCD80, SC79, SC75 1) ) CES-Code Month 2 0 03 2 0 04 2005 2006 2 0 07 2008 2009 2010 2011 2012 2 0 13 2014 01 a p A P a p A P a p A P 02 b q B Q b q B Q b q B Q 03 c r C R c r C R c r C R 04 d s D S d s D S d s D S 05 e t E T e t E T e t E T 06 f u F U f u F U f u F U 07 g v G V g v G V g v G V 08 h x H X h x H X h x H X 09 j y J Y j y J Y j y J Y 10 k z K Z k z K Z k z K Z 11 l 2 L 4 l 2 L 4 l 2 L 4 12 n 3 N 5 n 3 N 5 n 3 N 5 1) New Marking Layout for SC75, implemented at October 2005. . 7 2007-04-19 Package SOT23 BAR67... 0.4 +0.1 -0.05 1) 2 0.08...0.1 C 0.95 1.3 ±0.1 1 2.4 ±0.15 3 0.1 MAX. 10˚ MAX. B 1 ±0.1 10˚ MAX. 2.9 ±0.1 0.15 MIN. Package Outline A 5 0...8˚ 1.9 0.2 0.25 M B C M A 1) Lead width can be 0.6 max. in dambar area Foot Print 0.8 0.9 1.3 0.9 0.8 1.2 Marking Layout (Example) Manufacturer EH s 2005, June Date code (YM) Pin 1 BCW66 Type code Standard Packing Reel ø180 mm = 3.000 Pieces/Reel Reel ø330 mm = 10.000 Pieces/Reel 4 0.2 8 2.13 2.65 0.9 Pin 1 1.15 3.15 8 2007-04-19 BAR67... Edition 2006-02-01 Published by Infineon Technologies AG 81726 München, Germany © Infineon Technologies AG 2007. All Rights Reserved. Attention please! The information given in this dokument shall in no event be regarded as a guarantee of conditions or characteristics (“Beschaffenheitsgarantie”). With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind, including without limitation warranties of non-infringement of intellectual property rights of any third party. Information For further information on technology, delivery terms and conditions and prices please contact your nearest Infineon Technologies Office ( www.infineon.com). Warnings Due to technical requirements components may contain dangerous substances. For information on the types in question please contact your nearest Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered. 9 2007-04-19