PHILIPS CAX100

Philips Competence Centre Plastics B.V.
5722 650 3418
page 1/1
1997-12-10 1999-07-13
author: G Verkade
specification sheet
190 -1
All rights are reserved. Reproduction in whole or in part is prohibited
without the written consent of the copyright owner.
Optical Components
Datasheet Plastic Collimator Lens CAX100
These data concern a full plastic aspherical plano-convex lens. It is specified for use as a collimator in
combination with a diode laser. It can be mounted by use of glue or spring-loaded. Mechanical lockmounting is not advisable because of possible distortions.
Wavelength
Parameters
Unit
670 nm
Design conditions
N.A.
Clear Aperture CA
Designed with laser cover glass (BK7) on source side:
Distance from source
Glass thickness
0.20
4.1
-mm
0.55
0.25
mm
mm
10.0
9.21
8.48
mm
mm
mm
35
80
mλ
mλ
0.1
0.2
mm
mm
∅ 6.28
mm
-25 to 100
-10 to 75
°C
°C
5722 600 20173
N.V. PHILIPS' ELECTRONICS
Optical parameters
Focal Length
Back Focal Length BFL (incl BK7-glass)
Free Working Distance FWD
RMS mean
RMS max. (±3σ)
on axis
on axis
Optical Tolerance
Field Radius
Mechanical parameters
Alle rechten voorbehouden. Verveelvoudiging, geheel of gedeeltelijk
is niet toegestaan dan met schriftelijke toestemming van de
auteursrechthebbende.
Mounting hole diameter Dmh
Other parameters: see drawing
Environmental stability
Storage Temperature
Operating Temperature
General Data:
Transmission [%]: 90
Lens Material: Polycarbonate
Specifications subject to change without notice.
Zemax catalogue file available.