GLENAIR 390AA004M14

39
390-004
Water-Tight EMI/RFI Cable Sealing Backshell
with Strain Relief
Type A - Direct Coupling - Low Profile
CONNECTOR
DESIGNATORS
*
390 F S 004 M 16 10 E 6
A-B -C-D-E-F
G-H-J-K-L-S
* Conn. Desig. B See Note 6
DIRECT COUPLING
TYPE A OVERALL
SHIELD TERMINATION
Length ± .060 (1.52)
Min. Order Length 2.0 Inch
(See Note 4)
Product Series
Length: S only
(1/2 inch increments:
e.g. 6 = 3 inches)
Connector
Designator
Strain Relief Style (C, E)
Angle and Profile
A = 90°
B = 45°
S = Straight
Cable Entry (Tables X, XI)
Shell Size (Table I)
Basic Part No.
Finish (Table II)
A Thread
(Table I)
Length ± .060 (1.52)
Min. Order
Length 1.5 Inch
(See Note 4)
O-Rings
B
(Table I)
STYLE 2
(STRAIGHT
See Note 1)
E
J
(Table III) (Table
IV)
J
(Table
III)
F (Table IV)
B
(Table I)
G
(Table
IV)
B
(Table I)
H (Table IV)
STYLE C
Medium Duty
(Table X)
Clamping
Bars
T
Cable
Range
© 2005 Glenair, Inc.
STYLE E
Medium Duty
(Table XI)
X (See
Note 5)
Y
Cable
Range
W
CAGE Code 06324
Z
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
E-Mail: [email protected]
Series 39 - Page 22
www.glenair.com
39
390-004
Water-Tight EMI/RFI Cable Sealing Backshell
with Strain Relief
Type A - Direct Coupling - Low Profile
See inside back cover fold-out or pages 13 and 14 for Tables I and II.
Shell
Size
08/09
10/11
12/13
14/15
16/17
18/19
20/21
22/23
24/25
28/29
32/33
36
40
TABLE III: FRONT ADAPTER
J Max - Conn. Designator
A-D-E-F
C
J-H-L-S
B-G-K
1.000(25.4) 1.250(31.8)
1.000(25.4) 1.250(31.8)
1.000(25.4) 1.250(31.8) 1.735(44.1)
1.000(25.4) 1.250(31.8) 1.915(48.6)
1.000(25.4) 1.416(36.0) 1.915(48.6)
1.000(25.4) 1.416(36.0) 1.915(48.6)
1.000(25.4) 1.416(36.0) 1.915(48.6)
1.000(25.4) 1.416(36.0) 1.915(48.6)
1.000(25.4) 1.416(36.0) 1.915(48.6)
1.000(25.4) 1.416(36.0) 1.915(48.6)
1.000(25.4) 1.416(36.0) 1.915(48.6)
1.000(25.4) 1.416(36.0) 1.915(48.6)
1.000(25.4) 1.687(42.9) 1.915(48.6)
Dash
No.
03
04
06
08
10
12
16
20
24
28
32
Dash
No.
03
04
06
08
10
12
16
20
24
28
32
T
Max
1.219 (31.0)
1.219 (31.0)
1.219 (31.0)
1.219 (31.0)
1.281 (32.5)
1.281 (32.5)
1.406 (35.7)
1.656 (42.1)
1.906 (48.4)
1.906 (48.4)
2.000 (50.8)
Y
Max
.739 (18.8)
.739 (18.8)
.739 (18.8)
.739 (18.8)
.791 (20.1)
.880 (22.4)
.901 (22.9)
1.031 (26.2)
1.250 (31.8)
1.250 (31.8)
1.312 (33.3)
© 2005 Glenair, Inc.
TABLE IV: ELBOW DIMENSIONS
E
G
Dash
F
Max
Max
No.
Max
04 .630 (16.0) 1.250 (31.8) .636 (16.2)
06 .630 (16.0) 1.250 (31.8) .710 (18.0)
08 .692 (17.6) 1.312 (33.3) .731 (18.6)
10 .755 (19.2) 1.655 (42.0) .825 (21.0)
12 .848 (21.5) 1.765 (44.8) .988 (25.1)
16 1.036 (26.3) 1.952 (49.6) 1.087 (27.6)
20 1.130 (28.7) 2.098 (53.3) 1.325 (33.7)
24 1.255 (31.9) 2.155 (54.7) 1.337 (34.0)
28 1.317 (33.5) 2.250 (57.2) 1.827 (46.4)
32 1.348 (34.2) 2.343 (59.5) 2.027 (51.5)
H
Max
1.200 (30.5)
1.320 (33.5)
1.340 (34.0)
1.660 (42.2)
1.750 (44.5)
1.925 (48.9)
2.033 (51.6)
2.250 (57.2)
2.450 (62.2)
2.450 (62.2)
TABLE X: CABLE ENTRY
Cable Range
X
W
Ref
Min
Max
Max
.156 (4.0)
.135 (3.4)
.812 (20.6)
.219 (5.6)
.203 (5.2)
.188 (4.8)
.937 (23.8)
.312 (7.9)
.281 (7.1)
.285 (7.2)
1.062 (27.0)
.438 (11.1)
.350 (8.9)
.312 (7.9)
1.188 (30.2)
.531 (13.5)
.375 (9.5)
.390 (9.9)
1.312 (33.3)
.625 (15.9)
.460 (11.7)
.500 (12.7)
1.562 (39.7)
.750 (19.1)
.510 (13.0)
.625 (15.9)
1.750 (44.5)
.938 (23.8)
.695 (17.7)
.938 (23.8)
2.250 (57.2)
1.250 (31.8)
1.000 (25.4)
.715 (18.2)
2.375 (60.3)
1.375 (34.9)
.915 (23.2)
1.250 (31.8)
2.625 (66.7)
1.625 (41.3)
1.500 (38.1)
1.070 (27.2)
2.812 (71.4)
1.875 (47.6)
TABLE XI: CABLE ENTRY
Cable Range
Z
Max
Min
Max
.812 (20.6)
.156 (4.0)
.219 (5.6)
.937 (23.8)
.188 (4.8)
.312 (7.9)
1.062 (27.0)
.281 (7.1)
.438 (11.1)
1.188 (30.2)
.312 (7.9)
.531 (13.5)
1.312 (33.3)
.375 (9.5)
.625 (15.9)
1.562 (39.7)
.500 (12.7)
.750 (19.1)
1.750 (44.5)
.625 (15.9)
.938 (23.8)
2.250 (57.2)
.938 (23.8)
1.250 (31.8)
2.375 (60.3)
1.000 (25.4)
1.375 (34.9)
2.625 (66.7)
1.250 (31.8)
1.625 (41.3)
2.812 (71.4)
1.500 (38.1)
1.875 (47.6)
CAGE Code 06324
1. When maximum cable entry
(page 22) is exceeded, Style 2
will be supplied. (Function S
only).
2. Metric dimensions (mm) are
indicated in parentheses.
3. Cable range is defined as the
accommodations range for the
wire bundle or cable. Dimensions shown are not intended for
inspection criteria.
4. Consult factory for shorter
lengths on straight backshells.
5. Saddles are bottomed on Clamp
Ears.
6. When using Connector Designator B refer to pages 18 and 19 for
part number development.
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
E-Mail: [email protected]
Series 39 - Page 23
www.glenair.com