MI-200 Data Sheet

Data Sheet
MI-200
Features
• Inputs:
•
•
•
•
•
•
•
•
•
•
•
28 Vdc per MIL-STD-704D/E/F
155 Vdc per MIL-STD-1399A
270 Vdc per MIL-STD-704D/E/F
Single output: 2 – 48 Vdc
Up to 23 W/in3
MIL-STD-810 environments
Up to 90% efficiency
Remote sense
Current limit
OVP and thermal shutdown
Power boosters for higher power outputs
ZCS power architecture
Low noise FM control
Size: 4.6" x 2.4" x 0.5"
(116,8 x 61,0 x 12,7 mm)
DC-DC Converters
50 to 100 Watts
Converter Selection Chart
MI-2
Semi-custom driver and booster modules available, consult factory.
Input Voltage
Nominal
Product Highlights
2 = 28 V
The MI-200 family of DC-DC converters is
designed for applications utilizing distributed
power architectures. Based on Vicor’s VI-200 /
VI-J00 family of zero-current switching,
component level DC-DC converters, the MI-200
family offers exceptional performance in terms of
power density, efficiency, noise, ease of use, and
reliability.
Fully encapsulated in Vicor’s industry standard
package, the MI-Series meets MIL-STD-810
environmental requirements for humidity, fungus,
salt-fog, explosive atmosphere, acceleration,
vibration, and shock.
Standard features such as wide output trimming/programming, current limiting, remote
sense, output inhibit, and latching OVP and OTP
combine to offer the highest degree of protection,
versatility, and reliability for power systems.
[a]
[b]
[c]
18 – 50
V [b]
Notes
60 V
28 Vdc input per MIL-STD 704D/E/F
5 = 155 V
100 – 210 V
230 V
155 Vdc input per MIL-STD-1399A
6 = 270 V
125 – 400 V [c]
475 V
270 Vdc input per MIL-STD-704D/E/F
7 = 165 V
100 – 310 V
n/a
Transient voltage for 1 second
16 V operation at 75% load
MI-26Z-xV, MI-26Y-xV rated at 75% load from 125 – 150 VIN
Output Voltage
1 = 12 V
Z = 2.0 V
Y = 3.3 V
P = 13.8 V
0 = 5.0 V
2 = 15 V
X = 5.2 V
N = 18.5 V
W = 5.5 V
3 = 24 V
T = 6.5 V
[d]
J = 36 V
R = 7.5 V
[d]
K = 40 V
4 = 48 V
[d] 75 W max power for 28 V input
Standard: Slotted baseplate
SlimMod: Flangeless baseplate, option suffix: - S
Example: MI - 2XX - XX - S
Product Grade Temperature (°C)
Operating
Storage
I = –40 to + 85
M = –55 to + 85
I = –55 to +100
M = –65 to +100
Overtemperature shutdown 95°C typical
(recycle power to restart)
L = 28 V
V = 5.8 V
M = 10 V
Packaging Options
Transient [a]
Range
Output Power/Current VOUT
≥ 5V
Y = 50 W
X = 75 W
W= 100 W
V= —
<5 V
Y = 10 A
X = 15 A
W= 20 A
V = 30 A
For additional output power,
100 W and 75 W booster modules available
Change (MI-2xx-xx) to (MI-Bxx-xx)
FinMod: Finned heat sink, option suffix:
- F1, - F2, -F3 or -F4
Examples:
MI - 2XX - XX -F1, 0.25" fins, longitudinal
MI - 2XX - XX -F2, 0.50" fins, longitudinal
MI - 2XX - XX -F3, 0.25" fins, transverse
MI - 2XX - XX -F4, 0.50" fins, transverse
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MI-200 DC-DC Converters 50 to 100 Watts
Set your site on VICOR at vicorpower.com
Rev. 1.4
Page 1 of 6
CONVERTER SPECIFICATIONS
(typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified)
INPUT SPECIFICATIONS
Parameter
Min
Inrush charge
Typ
Max
120 x 10
Input reflected
ripple current – pp
-6
200 x 10
Nominal line
Nominal line, full load
30+ 20 Log VIN
dB
120 Hz, nominal line
IN
dB
2400 Hz, nominal line
( )
20+ 20 Log ( V )
VOUT
VOUT
No load power dissipation
Coulombs
Test Conditions
IIN
10%
Input ripple rejection
Units
-6
1.35
2
Watts
Typ
Max
Units
0.5%
1%
VNOM
0.05%
0.2%
VNOM
LL to HL, 10% to Full Load
0.2%
0.5%
VNOM
LL to HL, No Load to 10%
Output temperature drift
0.01
0.02
% / °C
Long term drift
0.02
OUTPUT CHARACTERISTICS
Parameter
Min
Setpoint accuracy
Load/line regulation
50%
Total remote
sense compensation
0.5
OVP set point [b]
115%
Current limit
Short circuit current [c]
Over rated temperature
%/1K hours
100
150
mV
1.0%
1.5%
VNOM
110%
VNOM
Output ripple – pp
Trim range [a]
Test Conditions
Whichever is greater
20 MHz bandwidth
Volts
125%
135%
VNOM
latching
105%
125%
INOM
Automatic restart
20%
130%
INOM
[a] 10 V, 12 V and 15 V outputs, standard trim range ±10%. Consult factory for wider trim range.
3.3 V output trim range 2.20 to 3.63 V
[b] No over temperature or voltage protection in booster modules
[c] Output voltages of 5 V or less incorporate foldback current limiting; outputs of 10 V and above provide constant current limiting.
CONTROL PIN SPECIFICATIONS
Parameter
Min
Typ
Max
Units
Gate out impedance
50
Ohms
Gate in impedance
1000
Ohms
6
Volts
Gate in open circuit voltage
Gate in low threshold
0.65
Gate in low current
Power sharing accuracy
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Use open collector
Volts
6
0.95
Test Conditions
mA
1.05
MI-200 DC-DC Converters 50 to 100 Watts
Set your site on VICOR at vicorpower.com
Rev. 1.4
Page 2 of 6
CONVERTER SPECIFICATIONS (cont.)
DIELECTRIC WITHSTAND CHARACTERISTICS
Parameter
Input to output
Output to baseplate
Input to baseplate
Min
Typ
Units
Test Conditions
3,000
VRMS
Baseplate earthed
500
VRMS
1,500
VRMS
Input to output capacitance
Max
50
75
pF
Typ
Max
Units
Test Conditions
°C/Watt
With thermal pads
THERMAL CHARACTERISTICS
Parameter
Min
Efficiency
80 – 90%
Baseplate to sink
thermal impedance
Thermal shutdown [d]
(Drivers only)
[d]
0.07
90
95
105
°C
Typ
Max
Units
Cool and recycle power
to restart
No over temperature or voltage protection in booster modules
ENVIRONMENTAL – MIL-STD-810D
Parameter
Min
Test Conditions
Altitude - method 500.2
70,000
feet
Procedure II
Humidity - method 507.2
86/240
%/hours
Acceleration - method 513.3
9
g
Procedure II
Vibration - method 514.3
20
g
Procedure I, category 6
Shock - method 516.3
40
g
Procedure I
Procedure I, cycle 1
RELIABILITY - MIL-HDBK-217F (MI-22L-MW)
Parameter
Min
Typ
Max
Units
25°C Ground Benign: G.B.
3,552
1,000 hours
50°C Naval Sheltered: N.S.
639
1,000 hours
65°C Airborne Inhabited
Cargo: A.I.C.
501
1,000 hours
Test Conditions
MECHANICAL SPECIFICATIONS
Parameter
Min
Typ
Max
Units
Weight
7.2
205
7.3
208
7.4
210
Ounces
Grams
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Test Conditions
MI-200 DC-DC Converters 50 to 100 Watts
Set your site on VICOR at vicorpower.com
Rev. 1.4
Page 3 of 6
CONVERTER SPECIFICATIONS (cont.)
PRODUCT GRADE SPECIFICATIONS
Parameter
I-Grade
M-Grade
Storage temperature
-55°C to +100°C
-65°C to +100°C
Operating temperature (baseplate)
-40°C to +85°C
-55°C to +85°C
12 hours, 29 cycles
96 hours, 213 cycles
12 cycles
-65°C to +100°C
12 cycles
-65°C to +100°C
-40°C, +80°C
-55°C, +80°C
2 years
2 years
MIL-STD-810
MIL-STD-810
NAVMAT P-4855-1A
NAVMAT P-4855-1A
Power cycling burn-in
Temperature cycled with power off
17°C per minute rate of change
Test data supplied at these temperatures [e]
Warranty
Environmental compliance
Derating
[e]
Test data available for review or download from vicorpower.com
ENVIRONMENTAL QUALIFICATIONS
Parameter
Qualification
MIL-STD-810D, Method 500.2, Procedure III, explosive decompression (40 K ft.).
Altitude
MIL-STD-810D, Method 500.2, Procedure II, 40,000 ft., 1000 – 1500 ft./ min. to 70,000 ft., unit functioning
Explosive Atmosphere
MIL-STD-810C, Method 511.1, Procedure I
MIL-STD-810D, Method 514.3, Procedure I, category 6, helicopter, 20 g
Vibration
MIL-STD-810D, Method 514.3 random: 10 – 300 Hz @ 0.02 g 2 /Hz, 2000 Hz @ 0.002 g 2 / Hz, 3.9 total G rms
3 hrs /axis. Sine: 30 Hz @ 20 g, 60 Hz @ 10 g, 90 Hz @ 6.6 g, 120 Hz @ 5.0 g, 16.0 total G rms, 3 axes
MIL-STD-810E, Method 514.4, Table 514.4-VII, ±6 db/octave, 7.7 G rms, 1hr/axis
MIL-STD-810D, Method 516.3, Procedure I, functional shock, 40 g
MIL-STD-202F, Method 213B, 18 pulses, 60 g, 9 msec
Shock
MIL-STD-202F, Method 213B, 75 g, 11 ms saw tooth shock
MIL-STD-202F, Method 207A, 3 impacts / axis, 1, 3, 5 feet
Acceleration
MIL-STD-810D, Method 513.3, Procedure II Operational test, 9 g for 1 minute along 3 mutually perpendicular axes
Humidity
MIL-STD-810D, Method 507.2, Procedure I, cycle I, 240 hrs, 88% relative humidity
Solder Test
MIL-STD-202, Method 208, 8 hr. aging
Fungus
MIL-STD-810C, Method 508.1
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MI-200 DC-DC Converters 50 to 100 Watts
Set your site on VICOR at vicorpower.com
Rev. 1.4
Page 4 of 6
MECHANICAL DRAWING
.50
(12,7)
.30±.015
(7,6)±(0,38)
1.80
(45,7)
4.60
(116,8)
3.60
(91,4)
Standard
0.080 (2,0) Dia (2) places
Solder plate over copper alloy
4
2.10
(53,3)
.15
(3,8)
9
3
2
8
7
6
1
5
VI-200
MI-200
1.40
1.00 (35,6)
.70 (25,4)
.40 (17,8)
(10,2)
.35±.015
(8,9)±(0,38)
FULL R
.15
(3,8)
Product ID
this surface
RoHS
0.080 (2,0) Dia (2) places
Matte tin over copper alloy
Pin # Function
1
+In
2
Gate In
3
Gate Out
4
-In
5
+Out
6*
+Sense
7*
Trim
8*
-Sense
9
-Out
* Do not connect on booster modules
Standard
.040 (1,0) Dia (7) places
Solder plate over copper alloy
RoHS
.040 (1,0) Dia (7) places
Matte tin over copper alloy
2.40
(61,0)
4.20
(106,7)
.22
(5,6) MIN
.50
(12,7)
.30
(7,6) Min
1.75 Max.
(44,5)
+.030 (0,76)
-.000 (0)
.01
.12
(3,0)
Aluminum Base
Note: For alternate packaging options refer to the mechanical drawing page of vicorpower.com
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MI-200 DC-DC Converters 50 to 100 Watts
Set your site on VICOR at vicorpower.com
Rev. 1.4
Page 5 of 6
Warranty
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal
use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance.
Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original purchaser only.
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warranty, the
buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned
without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the
factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty.
Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is assumed
for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve reliability, function,
or design. Vicor does not assume any liability arising out of the application or use of any product or circuit; neither does it convey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor Terms and
Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and indemnifies Vicor
against all damages.
Vicor’s comprehensive line of power solutions includes high density AC-DC
and DC-DC modules and accessory components, fully configurable AC-DC
and DC-DC power supplies, and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its
use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available upon
request.
Specifications are subject to change without notice.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent
applications) relating to the products described in this data sheet. Interested parties should contact Vicor's Intellectual
Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: [email protected]
Technical Support: [email protected]
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MI-200 DC-DC Converters 50 to 100 Watts
Set your site on VICOR at vicorpower.com
Rev. 1.4
04/11