cPCI200A-1C Series 200W 3Ux4HP AC/DC CompactPCI™ SELECTION GUIDE Output Current Model Number CPCI200A-1C Power 200W 5V 3.3V 12V -12V 25A 30A 5A 1A For full details go to www.murata-ps.com/rohs Yes Yes INPUT CHARACTERISTICS Parameter Conditions Min Typ Max Units Input Operating Voltage 90 264 Vac Input Frequency 47 63 Hz 3.5 Arms Input Current FEATURES 3Ux4HP package 200W power at 0-50ºC Power Factor 0.95 Inrush Current 240Vac Leakage Current 240VAC, 63Hz PICMG 2.11 Compliant OUTPUT CHARACTERISTICS Widerange 90-264VAC Input Output Nominal Voltage V12 Active power factor correction to EN61000-3-2 Class A conducted EMI performance 2 Output Current +5.0Vdc 1A3 25A +4/-2% 3 30A +4/-2% 5A ±4% 1A +12Vdc 0A 80% efficiency V4 -12Vdc 0A 1A Full power with just 250lfm airflow Parameter Conditions Min Typ Hot-swap capable Temperature Coefficient PARD (V1 & V2) 20MHz bandwidth 50 DESCRIPTION PARD (V3 & V4) 20MHz bandwidth 120 The cPCI200A-1C is a high-reliability, 200W, 3Ux4HP CompactPCI™ power supply developed for chassis’ with airflows as low as 250lfm. The use of resonant conversion and ORing FETs yields high efficiency which consequently permits packaging of this product in a compact, single card slot format (4HP). Output Power 50ºC, 250lfm airflow Output Power 70ºC, 250lfm airflow ±4% Max 0.02 Units %/ºC mVp-p 180 mVp-p 0 200 W 0 100 W ΔV, 50% load step ±5 %Vnom Settling time 500 μsec 135 %Vnom 16 msec Over-Voltage Protection V1, V2, & V3 Minimum Load4 V1 or V2 1 Output Holdup Time Full load, low line 12 Remote Sense Compensation5 V1, V2, & V3 250 Current Share Tolerance V1-V3; Io>25% Pri-Sec Notes: Total Regulation1 Max +3.3Vdc Isolation mA Min V3 With a widerange input of 90-264VAC, safety agency approvals to UL60950 and EN60950, EMI compliance to Class A FCC and EN55022 standards, the cPCI200A-1C was designed with globally-deployed systems in mind. Additional features include remote sense compensation, unit enable control (EN#), output inhibit control (INH#), output fault signal (FAL#), and thermal warning signal (DEG#). LEDs are provided for visual indication of input power presence and output fault condition. Apk 1 V2 The ORing FETs, current sharing, and synchronous start control allow the cPCI200A-1C to be operated in N+n parallel-redundant configurations. The low leakage current permits redundant configurations to comply with safety standards. The unit is capable of hot-swap performance to support high-availability enterprise applications. 0.99 35 47-pin I/O Connector Transient Response 0.98 125 A mV 10 % 3 kVac Pri-Chassis 1.5 kVac Sec-Chassis 500 Vac 1. Total regulation includes line, load, and cross regulation. 2. Maximum combined power from V1 & V2 not to exceed 125W. 3. Minimum load requirement of 1A may be fulfilled on either V1 or V2, but need not be applied to both. The unit will operate with less than the stated minimum, but full load on V3 & V4 is only achievable with the minimum load requirement met on V1 and/or V2. 4. Minimum load is for a single unit; units operated in parallel may require additional load to achieve full power on outputs V3 and V4. 5. Unit automatically reverts to local sensing if the sense lines are opened. Unit is protected against shorted or reversed sense lines. www.murata-ps.com cPCI200A-1C Series Rev D 02/2008 Page 1 of 4 cPCI200A-1C Series 200W 3Ux4HP AC/DC CompactPCI™ GENERAL CHARACTERISTICS Parameter Conditions Typ Max Units Efficiency Full load, 240Vac 79 81 % PFC Converter 100 kHz Main Converter 130 kHz Switching Frequency MTBF Calculated per Telcordia SR-332, Issue 1, 50ºC, 250lfm, ground benign Weight Unpackaged Min 200 khrs 620 g PROTECTION Parameter Conditions/Response Thermal Shutdown Automatic recovery upon restoration to operational temperatures Inception Min Typ Input Current Limit Input Protection Units Max 100 ºC 3 Arms Internal line fuse; Schurter 0034.6981 or equivalent 125 4 Arms 135 %Vnom Over-voltage Protection V1, V2, & V3 Parameter Conditions/Response Output Overload Protection Outputs are individually protected against overloads and indefinite short circuit with automatic recovery upon removal of the fault condition. Overload response for outputs V1-V3 is constant-current mode. Overload response for V4 is foldback; hiccup mode in response to a hard short. Hot-Swap Capability Design Verification Testing (DVT) confirms that voltage excursions on the output buses resulting from insertion/extraction events do not exceed the specified maximum of 5%. However, routing of power and signal lines in the mating backplane is critical to minimization of such excursions. In addition, performance can be critically affected by load characteristics including resistance, negative resistance, and reactive components. While the control loop responses have been designed for optimum hot-swap performance over a wide range of load characteristics, there may be instances where the voltage excursions exceed published specifications. In such cases, the control loop responses can be modified to perform optimally. Output Fault Isolation Output isolation devises are present in all outputs to isolate faults within a failed power supply. STATUS & CONTROL SIGNALS & INDICATORS Name Description Enable (EN#) Short pin on connector will enable the outputs when the mating pin is grounded. Supply will not power up until this pin is engaged to its mate in the backplane. Unit output will be inhibited as pin is disengaged from the mating connector. Output Inhibit (INH#) Secondary referenced; active low, TTL compatible. Logic “0” or short circuit to output return inhibits all outputs. Output Fault (FAL#) Secondary referenced; TTL compatible. Logic “0” denotes that one of the output voltages has fallen below the lower regulation limit. Remote Sense (RS+, RS-) Connection of the sense leads across the load at the desired point of regulation will compensate for voltage distribution drops up to 250mV between the output terminals of the power supply and the point of connection. The output is protected against shorted or open leads. Each of the Remote Sense lines must be terminated to the corresponding output and return lines in order guarantee all performance specifications. Thermal Warning (DEG#) Secondary referenced; TTL compatible. Logic “0” denotes a thermal warning; nominally, 10ºC prior to thermal shutdown. Sync Start (Sync) Interconnection of the sync start leads between cPCI200A-1 units connected in parallel permits synchronous starting to support loads that exceed the maximum for a single unit. Pin 35 (V1 Share) is used for the synchronous start function. Fault Indicator LED An LED will illuminate red if the output voltages are not within specification, coincident with assertion of the FAL# signal. This LED will also illuminate amber if the output is inhibited. Power Present Indicator LED A green LED will be illuminated when the input voltage is present and above the minimum requirement. ENVIRONMENTAL CHARACTERISTICS Parameter Conditions Min Ambient Operating Temperature Ambient Storage Temperature Operating Humidity Non-condensing Storage Humidity Non-condensing Altitude Max Units 0 Typ 50 ºC -40 125 ºC 10 90 % % 5 90 Operating. De-rate operating ambient temperature by 2Cº per 1000ft above 5000ft. -200 10000 ft Storage -200 50000 ft www.murata-ps.com cPCI200A-1C Series Rev D 02/2008 Page 2 of 4 cPCI200A-1C Series 200W 3Ux4HP AC/DC CompactPCI™ ELECTROMAGNETIC COMPATIBILITY (EMC) Characteristic Compliance Input Current Harmonics EN61000-3-2, Class A Conducted Emissions CFR Title 47, Part 15, Sub-part B, Class A EN55022, Class A Electrostatic Discharge (ESD) EN61000-4-2, Level 3, Criterion B Radiated Immunity EN61000-4-3, Level 3 Conducted Immunity EN61000-4-4, Level 3, Criterion A Line Voltage Surge EN61000-4-5, Level 2, Criterion B Line Voltage Interruptions EN61000-4-11 CERTIFICATIONS Agency/Characteristic Standard UL UL60950-1 CSA CSA60950-1 (per cUL) VDE EN60950-1 CE LVD Directive; self-certified RoHS EN Directive 2002/95/EC; self-certified (see Selection Guide for specific model compliances) SELV Certified Vibration MIL-STD-883F, Method 2007.3, Test Condition A, pending Shock MIL-STD-883F, Method 2002.4, Test Condition A, pending SAFETY AGENCY RATINGS Input Voltage 120/240Vac Input Current 3A Input Power 270W MECHANICAL DIMENSIONS www.murata-ps.com cPCI200A-1C Series Rev D 02/2008 Page 3 of 4 cPCI200A-1C Series 200W 3Ux4HP AC/DC CompactPCI™ CONNECTOR 1-4 5-12 13-18 19 20 21 22 23 24 25 26 27 28 293 30 31 323 33 34 35 36 373 38 39 403 413 42 433 443 45 46 47 Notes: RoHS COMPLIANT INFORMATION Staging Pin 1 M M M M M M M M M M M S M M M M M M M M M M M M M M M M M L M M 2 Signal Name Description V1 RTN V2 RTN V3 V4 RTN RESERVED RTN GA0 RESERVED EN# GA1 V1ADJ V1 SENSE GA2 V2ADJ V2 SENSE S RTN V1 SHARE V3 SENSE IPMB SCL DEG# INH# IPMB SDA V2 SHARE FAL# IPMB PWR V3 SHARE CGND ACN/+DC IN ACL/-DC IN V1 Output V1 and V2 Return V2 Output V3 Return V3 Output V4 Output Signal Return Reserved V4 Return Geographic Address Bit 0 Reserved Enable Geographic Address Bit 1 V1 Adjust V1 Remote Sense Geographic Address Bit 2 V2 Adjust V2 Remote Sense Sense Return Sync Start V3 Remote Sense IPMB Serial Clock Line Degrade Signal Inhibit IPMB Serial Data Line V2 Current Share Fail Signal IPMB Power Input V3 Current Share Chassis Grnd (Safety Grnd) AC Input Neutral/+DC Input AC Input Line/-DC Input This series is compatible with RoHS soldering systems with a peak wave solder temperature of 300ºC for 10 seconds. The pin termination finish on this product series is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The series is backward compatible with Sn/Pb soldering systems. For further information, please visit www.murata-ps.com/rohs 1. Pin numbers correspond to the female backpane connector. 2. “L” denotes long pin length (first mate, last break) “M” denotes medium pin length “S” denotes short pin length (last mate, first break) 3. This function not used in the CPCI200A-1C Series. ISO9001 CERTIFIED USA: Tucson (Az), Tel: (800) 547 2537, email: [email protected] Canada: Toronto, Tel: (866) 740 1232, email: [email protected] Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 www.murata-ps.com email: [email protected] ISO 9001 REGISTERED Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2008 Murata Power Solutions, Inc. UK: Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected] France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected] Germany: München, Tel: +49 (0)89-544334-0, email: [email protected] Japan: Tokyo, Tel: 3-3779-1031, email: [email protected] Osaka, Tel: 6-6354-2025, email: [email protected] Website: www.murata-ps.jp China: Shanghai, Tel: +86 215 027 3678, email: [email protected] Guangzhou, Tel: +86 208 221 8066, email: [email protected] www.murata-ps.com cPCI200A-1C Series Rev D 02/2008 Page 4 of 4