MURATA CPCI500D-1C

cPCI500 Series
500W 6Ux4HP DC/DC CompactPCI™ Power Supply
SELECTION GUIDE
S
Model Number
Power
Output Current
5V
3.3V
12V
-12V
IPMI
Ish1
CPCI500D-1
C
500W
55A
Y
11A
1.7A
N
P
No
CPCI500D-2
C
500W
30A
N
11A
1.7A
N
P
No
C
CPCI500D-3
500W
30A
N
11A
1.7A
Y
A
No
C
CPCI500D-4
500W
55A
Y
11A
1.7A
Y
A
No
No
CPCI500D-5
C
500W
55A
N
11A
1.7A
N
A
FEATURES
C
CPCI500D-6
500W
30A
N
11A
1.7A
N
A
No
6Ux4HP package
CPCI500D-1C
C
500W
55A
Y
11A
1.7A
N
P
Yes
500W power at 0-50ºC
C
CPCI500D-2C
C
500W
30A
N
11A
1.7A
N
P
Yes
PICMG 2.11 compliant
CPCI500D-3C
C
500W
30A
N
11A
1.7A
Y
A
Yes
RoHS compliant
CPCI500D-4C
C
500W
55A
Y
11A
1.7A
Y
A
Yes
CPCI500D-5C
C
500W
55A
N
11A
1.7A
N
A
Yes
CPCI500D-6C
C
500W
30A
N
11A
1.7A
N
A
Yes
Widerange 36-72Vdc input
nput range
IPMI option
Active or passive current
ent sharing
47-pin I/O Connector
INPUT CHARACTERISTICS
Parameter
Conditions
Min
Typ
Max
Units
80% efficiency
Input Operating Voltage
36
72
Vdc
No minimum load
Input Voltage Withstand
34
75
Vdc
Hot-swap capable
Inrush Current
36Vdc input
25
Apk
72Vdc input
50
Apk
DESCRIPTION
The cPCI500 is a high-reliability, 500W, 6ux4HP
CompactPCI™ power supply operating from widerange DC-input. The use of our patented V-Series
topology yields high efficiency which consequently
permits packaging of this product in a compact, single
card slot format (4HP).
ORing diodes and current sharing allow the cPCI500 to
be operated in N+n parallel-redundant configurations.
Available with an IPMI interface option, the cPCI500
was designed for hot-swap, redundant configurations
to support high-availability (HA) telecom applications.
OUTPUT CHARACTERISTICS
Output
Nominal Voltage
V1
Output Current
Max A
Max B
+5.0Vdc
0A
55A
30A
±1%
V2
+3.3Vdc
0A
30A
60A
±1%
V3
+12Vdc
0A
11A
11A
±1%
V4
-12Vdc
0A
1.7A
1.7A
±3%
Parameter
Conditions
Min
Typ
Max
Units
0.02
%/ºC
Temperature Coefficient
With a widerange input of 36-72Vdc, safety agency
approvals to UL60950 and EN60950, EMI compliance
to ETSI and Telcordia standards, the cPCI500 was
designed with globally-deployed systems in mind.
Additional features include remote sense compensation,
unit enable control (EN#), output inhibit control (INH#),
output fault signal (FAL#), and thermal warning signal
(DEG#). LEDs are provided for visual indication of input
power presence and output fault condition.
PARD (V1 & V2)
20MHz bandwidth
PARD (V3 & V4)
20MHz bandwidth
Output Power
50ºC, 400lfm airflow
Output Power
70ºC, 400lfm airflow
The 4HP package and complement of global
safety agency approvals provide for an advanced,
high-density, high-efficiency power solution for your
CompactPCI requirements.
Minimum Load
Transient Response
Over-Voltage Protection
mVp-p
180
mVp-p
0
500
W
0
250
W
±8
%Vnom
ΔV, 50% load step
Settling time
All outputs
125
12
Remote Sense Compensation
V1, V2 & V3
300
Current Share Tolerance
V1-V3; full load
Isolation
200
μsec
135
%Vnom
16
msec
0
Full load, low line
Notes:
www.murata-ps.com
50
120
Output Holdup Tim
For full details go to
www.murata-ps.com/rohs
Total Regulation1
Min
A
mV
±10
%
Pri-Sec
4
kVac
Pri-Chassis
1.5
kVac
Sec-Chassis
500
Vac
1 Total regulation includes line, load, and cross regulation.
Technical enquiries email: [email protected], tel: +1 508 339 3000
TDC_cPCI500 Series.B01 Page 1 of 4
cPCI500 Series
500W 6Ux4HP DC/DC CompactPCI™ Power Supply
GENERAL CHARACTERISTICS
Parameter
Conditions
Efficiency
48Vdc input, 500W load (dependent upon load profile)
Min
Typ
Switching Frequency
MTBF
Calculated per MIL-HDBK-217F, 25ºC, ground benign
Weight
Unpackaged
Max
Units
65
%
72
kHz
84
khrs
3.6
kg
PROTECTION
Parameter
Inception
Conditions/Response
Min
Typ
Thermal Shutdown
Automatic recovery upon restoration to operational temperatures
90
Output Power Limit
Automatic recovery
530
Input Protection
Internal line fuse, Littlefuse BLN 25P ROHS or equivalent
Over-voltage Protection
Output V1, latching
6.0
Output V2, latching
3.9
Max
Units
ºC
W
25
A
6.5
7.0
Vdc
4.3
4.7
Vdc
Parameter
Conditions/Response
Output Overload Protection
Outputs are individually protected against overloads and indefinite short circuit with automatic recovery upon removal of the fault condition.
Hot-Swap Capability
Design Verification Testing (DVT) confirms that voltage excursions on the output buses resulting from insertion/extraction events do not exceed the
specified maximum of 5%. However, routing of power and signal lines in the mating backplane is critical to minimization of such excursions. In
addition, performance can be critically affected by load characteristics including resistance, negative resistance, and reactive components. While
the control loop responses have been designed for optimum hot-swap performance over a wide range of characteristics, there may be instances
where the voltage excursions exceed published specifications. In such cases, the control loop responses can be modified to perform optimally.
Output Fault Isolation
Output isolation devices are present in all outputs to isolate faults within a failed power supply.
STATUS & CONTROL SIGNALS & INDICATORS
Name
Description
Hot-Swap Enable
Short pin on connector will enable the outputs when the mating pin is tied to DC GRD. Supply will not power up until this pin is engaged to its
mate in the backplane. Unit output will be inhibited as pin is disengaged from the mating connector.
Output Inhibit
Secondary referenced; active low, TTL compatible. Logic “0” or short circuit to Logic RTN (pin 40 or 43) inhibits all outputs.
DC Good
Secondary referenced. Open collector signal with an internal 2.2k pull-up resistor is connected to the +5V output. TTL signal will transition high
when all outputs are between 90% and 110% of their nominal voltage.
Remote Sense
Connection of the sense leads across the load at the desired point of regulation will compensate for voltage distribution drops up to 700mV
between the output terminals of the power supply and the point of connection. The unit reverts to local sensing if the sense lines are opened for
any reason. The output is protected against shorted or open leads. Applies to all outputs.
Fan Alarm
Secondary referenced; TTL compatible; active low. Signal transitions to a Logic 0 denotes a thermal warning.
Power Present Indicator LED
A green LED will be illuminated when the input voltage is present and above the minimum requirement.
DC Good Indicator LED
A green LED will be illuminated when the output voltages are within 90-110% of specification, coincident with assertion of the DC Good signal.
This LED will be extinguished if any of the output voltages is outside of this range.
Fan Good Indicator LED
A green LED will be illuminated when the fan is operational, coincident with de-assertion of the Fan Alarm signal. This LED will be extinguished in
the event of a fan failure.
Sync Start
A power supply generated signal used to simultaneously start power supplies connected in parallel when the load on any output exceeds a single
power supply’s capacity for that output. These pins must be bused together at the backplane in parallel/redundant applications (N+n) when N>1.
In simple redundant (1+1) or non-parallel applications (1+0), the pin can be ignored.
Power Supply Present
This pin presents a DC ground signal to the mating pin in the backplane. It is intended to be used by the system to detect the presence of a
power supply when the supply is mated into an available position.
ENVIRONMENTAL CHARACTERISTICS
Parameter
Conditions
AmbientOperatingTemperature
De-rate output power linearly above 40ºC to 250W at 60ºC.
Min
Ambient Storage Temperature
Humidity
Altitude
Cooling
www.murata-ps.com
Max
Units
0
Typ
60
ºC
ºC
-25
+125
Operating; non-condensing
10
95
%
Storage; non-condensing
5
95
%
Operating. De-rate ambient temperature by 2Cº per 1000ft above 5000ft.
-200
10000
ft
Storage
-200
40000
ft
Self-cooled by internal fan
Technical enquiries email: [email protected], tel: +1 508 339 3000
TDC_cPCI500 Series.B01 Page 2 of 4
cPCI500 Series
500W 6Ux4HP DC/DC CompactPCI™ Power Supply
CERTIFICATIONS
Agency/Characteristic
Standard
UL
UL1950
CSA
CSA950 (per cUL)
VDE
EN60950
CE
LVD Directive; self-certified
RoHS
EN Directive 2002/95/EC; self-certified; see Selection Guide table for specific model compliance
SELV
Self-certified
Vibration
MIL-STD-810F, Method 514.5, Procedure I; self-certified
Shock
MIL-STD-810F, Method 516.5, Procedure I; self-certified
ELECTROMAGNETIC COMPATABILITY (EMC)
Conducted Emissions
EN 300 386, NEBS GR-1089
Electrostatic Discharge (ESD)
EN61000-4-2, Level 3, Criteria B
Radiated Immunity
EN61000-4-3, Level 3, Criteria A
Conducted Immunity
EN61000-4-4, Level 3, Criteria A
Line Voltage Surge
EN61000-4-5, Class 3, Criteria B
MECHANICAL DIMENSIONS
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
TDC_cPCI500 Series.B01 Page 3 of 4
cPCI500 Series
500W 6Ux4HP DC/DC CompactPCI™ Power Supply
PACKAGE SPECIFICATIONS
IPMI/IPMB POWER SUPPLY SATELLITE CONTROLLER FEATURES
CONNECTOR
Complies with IPMI V1.5 Rev 1.1 and IPMB V1.0
Complies to PICMG2.9 (CompactPCI Systems Management
Specification)
8 Analog inputs configured for monitoring voltages and currents on
power supply outputs V1 - V4
Monitors the state of the thermal sensor
Output inhibit control can be overwritten by IPMI commands
Self Test with LED indicator (can be read and overwritten by IPMI
commands)
6 programmable thresholds on each analog sensor
Each threshold on each sensor can be enabled to generate event
messages if that threshold is crossed
Thermal sensor can be enabled to generate event messages
Responds to all mandatory IPMI commands and numerous optional
commands as indicated in the functional specification
Firmware can be upgraded via the IPMB bus
Includes Device SDR’s (Sensor Data Records) - These specify the type
of sensor for each input (voltage, current, temperature, etc.) as well as
the conversion formulas from raw ADC data to voltages, currents, etc.
Includes FRU type information such as Model Number, serial number
and firmware creation date
Pin #1
Staging2
Signal Name
Description
1-4
M
V1
V1 Output
5-12
M
RTN
V1 and V2 Return
13-18
M
V2
V2 Output
19
M
RTN
V3 Return
20
M
V3
V3 Output
21
M
V4
V4 Output
22
M
RTN
Signal Return
23
M
RESERVED
Reserved
24
M
RTN
V4 Return
25
M
GA0
Geographic Address Bit 0
26
M
RESERVED
Reserved
27
S
EN#
Enable
28
M
GA1
Geographic Address Bit 1
29
M
V1ADJ
V1 Adjust
30
M
V1 SENSE
V1 Remote Sense
31
M
GA2
Geographic Address Bit 2
MECHANICAL
32
M
V2ADJ
V2 Adjust
Shock: MIL-STD-810d, Method 516.3, Procedure 1.
33
M
V2 SENSE
V2 Remote Sense
Vibration: MIL-STD-810d, Method 514.3, Procedure 1.
34
M
S RTN
Sense Return
Dimensions: 6U x 4HP x 160mm (see Mechanical above)
35
M
V1 SHARE
V1 Current Share
EMC & SAFETY
36
M
V3 SENSE
V3 Remote Sense
EMI: NEBS Compliant, ETSI Compliant
37
M
IPMB SCL
IPMB Serial Clock Line
Safety Agency Ratings
38
M
DEG#
Degrade Signal
Input Voltage: 48 VDC
39
M
INH#
Inhibit
Input Current: 15A
40
M
IPMB SDA
IPMB Serial Data Line
Input Power: 620W
41
M
V2 SHARE
V2 Current Share
Agency Approvals
42
M
FAL#
Fail Signal
UL1950/CSA950, EN60950, CE Mark.
43
M
IPMB PWR
IPMB Power Input
(Low Voltage Directive)
NOTES:
44
M
V3 SHARE
V3 Current Share
45
L
CGND
Chassis Grnd (Safety Grnd)
46
M
ACN/+DC IN
AC Input Neutral/+DC Input
47
M
ACL/-DC IN
AC Input Line/-DC Input
(1) Pin numbers correspond to the female backplane connector.
(2) L = Long Length Pin (First Make, Last Break); M = Medium
Length Pins; S = Short Length Pins (Last Make, First Break)
SAFETY AGENCY RATINGS
USA:
Input Voltage
36-72Vdc
Input Current
25-12.5Adc
Input Power
620W
Mansfield (MA), Tel: (508) 339-3000, email: [email protected]
Canada: Toronto, Tel: (866) 740-1232, email: [email protected]
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
UK:
Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected]
France:
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected]
Germany: München, Tel: +49 (0)89-544334-0, email: [email protected]
www.murata-ps.com email: [email protected] ISO 9001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2008 Murata Power Solutions, Inc.
Japan:
Tokyo, Tel: 3-3779-1031, email: [email protected]
Osaka, Tel: 6-6354-2025, email: [email protected]
Website: www.murata-ps.jp
China:
Shanghai, Tel: +86 215 027 3678, email: [email protected]
Guangzhou, Tel: +86 208 221 8066, email: [email protected]
05/14/08
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
TDC_cPCI500 Series.B01 Page 4 of 4