*LAST TIME BUY: 3/31/2015. CLICK HERE FOR OBSOLESCENCE NOTICE OF 10/31/2014. cPCI200A-1C Series www.murata-ps.com 200W 3Ux4HP AC/DC CompactPCI™ SELECTION GUIDE To Be Discontinued* Output Current Model Number CPCI200A-1C Power 200W 5V 3.3V 12V -12V 25A 30A 5A 1A For full details go to www.murata-ps.com/rohs Yes Yes INPUT CHARACTERISTICS Parameter Conditions Min Typ 90 264 Vac Input Frequency 47 63 Hz 3.5 Arms Power Factor n 3Ux4HP package n 200W power at 0-50ºC 0.95 Inrush Current 240Vac Leakage Current 240VAC, 63Hz n PICMG 2.11 Compliant OUTPUT CHARACTERISTICS n Widerange 90-264VAC Input Output Nominal Voltage V12 n Active power factor correction to EN61000-3-2 n Class A conducted EMI performance Units Input Operating Voltage Input Current FEATURES Max 0.98 0.99 35 Apk 1 Output Current mA Total Regulation1 Min Max +5.0Vdc 1A3 25A +4/-2% V2 +3.3Vdc 1A 30A +4/-2% n 47-pin I/O Connector V3 +12Vdc 0A 5A ±4% n 80% efficiency V4 -12Vdc 0A 1A n Full power with just 250lfm airflow Parameter Conditions Min Typ n Hot-swap capable Temperature Coefficient PARD (V1 & V2) 20MHz bandwidth 50 DESCRIPTION PARD (V3 & V4) 20MHz bandwidth 120 The cPCI200A-1C is a high-reliability, 200W, 3Ux4HP CompactPCI™ power supply developed for chassis’ with airflows as low as 250lfm. The use of resonant conversion and ORing FETs yields high efficiency which consequently permits packaging of this product in a compact, single card slot format (4HP). Output Power 50ºC, 250lfm airflow Output Power 70ºC, 250lfm airflow 2 Transient Response The ORing FETs, current sharing, and synchronous start control allow the cPCI200A-1C to be operated in N+n parallel-redundant configurations. The low leakage current permits redundant configurations to comply with safety standards. The unit is capable of hot-swap performance to support high-availability enterprise applications. With a widerange input of 90-264VAC, safety agency approvals to UL60950 and EN60950, EMI compliance to Class A FCC and EN55022 standards, the cPCI200A-1C was designed with globally-deployed systems in mind. Additional features include remote sense compensation, unit enable control (EN#), output inhibit control (INH#), output fault signal (FAL#), and thermal warning signal (DEG#). LEDs are provided for visual indication of input power presence and output fault condition. 3 0.02 Units %/ºC mVp-p 180 mVp-p 0 200 W 0 100 W ΔV, 50% load step ±5 %Vnom Settling time 500 μsec 135 %Vnom 16 msec Over-Voltage Protection V1, V2, & V3 Minimum Load4 V1 or V2 1 Output Holdup Time Full load, low line 12 Remote Sense Compensation5 V1, V2, & V3 250 Current Share Tolerance V1-V3; Io>25% Pri-Sec Isolation ±4% Max 125 A mV 10 % 3 kVac Pri-Chassis 1.5 kVac Sec-Chassis 500 Vac Notes: 1. Total regulation includes line, load, and cross regulation. 2. Maximum combined power from V1 & V2 not to exceed 125W. 3. Minimum load requirement of 1A may be fulfilled on either V1 or V2, but need not be applied to both. The unit will operate with less than the stated minimum, but full load on V3 & V4 is only achievable with the minimum load requirement met on V1 and/or V2. 4. Minimum load is for a single unit; units operated in parallel may require additional load to achieve full power on outputs V3 and V4. 5. Unit automatically reverts to local sensing if the sense lines are opened. Unit is protected against shorted or reversed sense lines. www.murata-ps.com/support cPCI200A-1C Series.E01 Page 1 of 4 cPCI200A-1C Series 200W 3Ux4HP AC/DC CompactPCI™ GENERAL CHARACTERISTICS Parameter Conditions Efficiency Full load, 240Vac Switching Frequency Min Typ Max Units 79 81 % PFC Converter 100 kHz Main Converter 130 kHz MTBF Calculated per Telcordia SR-332, Issue 1, 50ºC, 250lfm, ground benign Weight Unpackaged 200 khrs 620 g PROTECTION Parameter Conditions/Response Thermal Shutdown Automatic recovery upon restoration to operational temperatures Inception Min Input Current Limit Typ Max Units 100 ºC 3 Arms Input Protection Internal line fuse; Schurter 0034.6981 or equivalent Over-voltage Protection V1, V2, & V3 Parameter Conditions/Response Output Overload Protection Outputs are individually protected against overloads and indefinite short circuit with automatic recovery upon removal of the fault condition. Overload response for outputs V1-V3 is constant-current mode. Overload response for V4 is foldback; hiccup mode in response to a hard short. Hot-Swap Capability Design Verification Testing (DVT) confirms that voltage excursions on the output buses resulting from insertion/extraction events do not exceed the specified maximum of 5%. However, routing of power and signal lines in the mating backplane is critical to minimization of such excursions. In addition, performance can be critically affected by load characteristics including resistance, negative resistance, and reactive components. While the control loop responses have been designed for optimum hot-swap performance over a wide range of load characteristics, there may be instances where the voltage excursions exceed published specifications. In such cases, the control loop responses can be modified to perform optimally. Output Fault Isolation Output isolation devises are present in all outputs to isolate faults within a failed power supply. 125 4 Arms 135 %Vnom STATUS & CONTROL SIGNALS & INDICATORS Name Description Enable (EN#) Short pin on connector will enable the outputs when the mating pin is grounded. Supply will not power up until this pin is engaged to its mate in the backplane. Unit output will be inhibited as pin is disengaged from the mating connector. Output Inhibit (INH#) Secondary referenced; active low, TTL compatible. Logic “0” or short circuit to output return inhibits all outputs. Output Fault (FAL#) Secondary referenced; TTL compatible. Logic “0” denotes that one of the output voltages has fallen below the lower regulation limit. Remote Sense (RS+, RS-) Connection of the sense leads across the load at the desired point of regulation will compensate for voltage distribution drops up to 250mV between the output terminals of the power supply and the point of connection. The output is protected against shorted or open leads. Each of the Remote Sense lines must be terminated to the corresponding output and return lines in order guarantee all performance specifications. Thermal Warning (DEG#) Secondary referenced; TTL compatible. Logic “0” denotes a thermal warning; nominally, 10ºC prior to thermal shutdown. Sync Start (Sync) Interconnection of the sync start leads between cPCI200A-1 units connected in parallel permits synchronous starting to support loads that exceed the maximum for a single unit. Pin 35 (V1 Share) is used for the synchronous start function. Fault Indicator LED An LED will illuminate red if the output voltages are not within specification, coincident with assertion of the FAL# signal. This LED will also illuminate amber if the output is inhibited. Power Present Indicator LED A green LED will be illuminated when the input voltage is present and above the minimum requirement. ENVIRONMENTAL CHARACTERISTICS Parameter Conditions Ambient Operating Temperature Ambient Storage Temperature Operating Humidity Non-condensing Storage Humidity Non-condensing Altitude Min Max Units 0 Typ 50 ºC -40 125 ºC 10 90 % 5 90 % Operating. De-rate operating ambient temperature by 2Cº per 1000ft above 5000ft. -200 10000 ft Storage -200 50000 ft www.murata-ps.com/support cPCI200A-1C Series.E01 Page 2 of 4 cPCI200A-1C Series 200W 3Ux4HP AC/DC CompactPCI™ ELECTROMAGNETIC COMPATIBILITY (EMC) Characteristic Compliance Input Current Harmonics EN61000-3-2, Class A Conducted Emissions CFR Title 47, Part 15, Sub-part B, Class A EN55022, Class A Electrostatic Discharge (ESD) EN61000-4-2, Level 3, Criterion B Radiated Immunity EN61000-4-3, Level 3 Conducted Immunity EN61000-4-4, Level 3, Criterion A Line Voltage Surge EN61000-4-5, Level 2, Criterion B Line Voltage Interruptions EN61000-4-11 CERTIFICATIONS Agency/Characteristic Standard UL UL60950-1 CSA CSA60950-1 (per cUL) VDE EN60950-1 CE LVD Directive; self-certified RoHS EN Directive 2002/95/EC; self-certified (see Selection Guide for specific model compliances) SELV Certified Vibration MIL-STD-883F, Method 2007.3, Test Condition A, pending Shock MIL-STD-883F, Method 2002.4, Test Condition A, pending SAFETY AGENCY RATINGS Input Voltage 120/240Vac Input Current 3A Input Power 270W MECHANICAL DIMENSIONS www.murata-ps.com/support cPCI200A-1C Series.E01 Page 3 of 4 cPCI200A-1C Series 200W 3Ux4HP AC/DC CompactPCI™ CONNECTOR RoHS COMPLIANT INFORMATION Pin Staging Signal Name Description 1-4 5-12 13-18 19 20 21 22 23 24 25 26 27 28 293 30 31 323 33 34 35 36 373 38 39 403 413 42 433 443 45 46 47 V1V1 Output RTN V1 and V2 Return V2V2 Output RTNV3 Return V3V3 Output V4V4 Output RTNSignal Return RESERVEDReserved RTNV4 Return GA0 Geographic Address Bit 0 RESERVEDReserved EN#Enable GA1 Geographic Address Bit 1 V1ADJ V1 Adjust V1 SENSE V1 Remote Sense GA2 Geographic Address Bit 2 V2ADJ V2 Adjust V2 SENSE V2 Remote Sense S RTN Sense Return V1 SHARE Sync Start V3 SENSE V3 Remote Sense IPMB SCL IPMB Serial Clock Line DEG#Degrade Signal INH#Inhibit IPMB SDA IPMB Serial Data Line V2 SHARE V2 Current Share FAL#Fail Signal IPMB PWR IPMB Power Input V3 SHARE V3 Current Share CGND Chassis Grnd (Safety Grnd) ACN/+DC IN AC Input Neutral/+DC Input ACL/-DC IN AC Input Line/-DC Input 1 Notes: 2 M M M M M M M M M M M S M M M M M M M M M M M M M M M M M L M M This series is compatible with RoHS soldering systems with a peak wave solder temperature of 300ºC for 10 seconds. The pin termination finish on this product series is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The series is backward compatible with Sn/Pb soldering systems. For further information, please visit www.murata-ps.com/rohs 1. Pin numbers correspond to the female backpane connector. 2. “L” denotes long pin length (first mate, last break) “M” denotes medium pin length “S” denotes short pin length (last mate, first break) 3. This function not used in the CPCI200A-1C Series. ISO9001 CERTIFIED Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2014 Murata Power Solutions, Inc. www.murata-ps.com/support cPCI200A-1C Series.E01 Page 4 of 4