cPCI200A-1C Series

*LAST TIME BUY: 3/31/2015. CLICK HERE FOR OBSOLESCENCE NOTICE OF 10/31/2014.
cPCI200A-1C Series
www.murata-ps.com
200W 3Ux4HP AC/DC CompactPCI™
SELECTION GUIDE
To Be Discontinued*
Output Current
Model Number
CPCI200A-1C
Power
200W
5V
3.3V
12V
-12V
25A
30A
5A
1A
For full details go to
www.murata-ps.com/rohs
Yes
Yes
INPUT CHARACTERISTICS
Parameter
Conditions
Min
Typ
90
264
Vac
Input Frequency
47
63
Hz
3.5
Arms
Power Factor
n 3Ux4HP package
n 200W power at 0-50ºC
0.95
Inrush Current
240Vac
Leakage Current
240VAC, 63Hz
n PICMG 2.11 Compliant
OUTPUT CHARACTERISTICS
n Widerange 90-264VAC Input
Output
Nominal Voltage
V12
n Active power factor correction to EN61000-3-2
n Class A conducted EMI performance
Units
Input Operating Voltage
Input Current
FEATURES
Max
0.98
0.99
35
Apk
1
Output Current
mA
Total Regulation1
Min
Max
+5.0Vdc
1A3
25A
+4/-2%
V2
+3.3Vdc
1A
30A
+4/-2%
n 47-pin I/O Connector
V3
+12Vdc
0A
5A
±4%
n 80% efficiency
V4
-12Vdc
0A
1A
n Full power with just 250lfm airflow
Parameter
Conditions
Min
Typ
n Hot-swap capable
Temperature Coefficient
PARD (V1 & V2)
20MHz bandwidth
50
DESCRIPTION
PARD (V3 & V4)
20MHz bandwidth
120
The cPCI200A-1C is a high-reliability, 200W, 3Ux4HP
CompactPCI™ power supply developed for chassis’
with airflows as low as 250lfm. The use of resonant
conversion and ORing FETs yields high efficiency which
consequently permits packaging of this product in a
compact, single card slot format (4HP).
Output Power
50ºC, 250lfm airflow
Output Power
70ºC, 250lfm airflow
2
Transient Response
The ORing FETs, current sharing, and synchronous start
control allow the cPCI200A-1C to be operated in N+n
parallel-redundant configurations. The low leakage
current permits redundant configurations to comply
with safety standards. The unit is capable of hot-swap
performance to support high-availability enterprise
applications.
With a widerange input of 90-264VAC, safety
agency approvals to UL60950 and EN60950, EMI
compliance to Class A FCC and EN55022 standards,
the cPCI200A-1C was designed with globally-deployed
systems in mind. Additional features include remote
sense compensation, unit enable control (EN#), output
inhibit control (INH#), output fault signal (FAL#), and
thermal warning signal (DEG#). LEDs are provided for
visual indication of input power presence and output
fault condition.
3
0.02
Units
%/ºC
mVp-p
180
mVp-p
0
200
W
0
100
W
ΔV, 50% load step
±5
%Vnom
Settling time
500
μsec
135
%Vnom
16
msec
Over-Voltage Protection
V1, V2, & V3
Minimum Load4
V1 or V2
1
Output Holdup Time
Full load, low line
12
Remote Sense Compensation5
V1, V2, & V3
250
Current Share Tolerance
V1-V3; Io>25%
Pri-Sec
Isolation
±4%
Max
125
A
mV
10
%
3
kVac
Pri-Chassis
1.5
kVac
Sec-Chassis
500
Vac
Notes:
1. Total regulation includes line, load, and cross regulation.
2. Maximum combined power from V1 & V2 not to exceed 125W.
3. Minimum load requirement of 1A may be fulfilled on either V1 or V2, but need not be applied to both.
The unit will operate with less than the stated minimum, but full load on V3 & V4 is only achievable with
the minimum load requirement met on V1 and/or V2.
4. Minimum load is for a single unit; units operated in parallel may require additional load to achieve full
power on outputs V3 and V4.
5. Unit automatically reverts to local sensing if the sense lines are opened. Unit is protected against shorted
or reversed sense lines.
www.murata-ps.com/support
cPCI200A-1C Series.E01 Page 1 of 4
cPCI200A-1C Series
200W 3Ux4HP AC/DC CompactPCI™
GENERAL CHARACTERISTICS
Parameter
Conditions
Efficiency
Full load, 240Vac
Switching Frequency
Min
Typ
Max
Units
79
81
%
PFC Converter
100
kHz
Main Converter
130
kHz
MTBF
Calculated per Telcordia SR-332, Issue 1, 50ºC, 250lfm, ground benign
Weight
Unpackaged
200
khrs
620
g
PROTECTION
Parameter
Conditions/Response
Thermal Shutdown
Automatic recovery upon restoration to operational temperatures
Inception
Min
Input Current Limit
Typ
Max
Units
100
ºC
3
Arms
Input Protection
Internal line fuse; Schurter 0034.6981 or equivalent
Over-voltage Protection
V1, V2, & V3
Parameter
Conditions/Response
Output Overload Protection
Outputs are individually protected against overloads and indefinite short circuit with automatic recovery upon removal of the fault condition.
Overload response for outputs V1-V3 is constant-current mode. Overload response for V4 is foldback; hiccup mode in response to a hard short.
Hot-Swap Capability
Design Verification Testing (DVT) confirms that voltage excursions on the output buses resulting from insertion/extraction events do not exceed
the specified maximum of 5%. However, routing of power and signal lines in the mating backplane is critical to minimization of such excursions.
In addition, performance can be critically affected by load characteristics including resistance, negative resistance, and reactive components.
While the control loop responses have been designed for optimum hot-swap performance over a wide range of load characteristics, there may be instances where the voltage excursions exceed published specifications. In such cases, the control loop responses can be modified to perform optimally.
Output Fault Isolation
Output isolation devises are present in all outputs to isolate faults within a failed power supply.
125
4
Arms
135
%Vnom
STATUS & CONTROL SIGNALS & INDICATORS
Name
Description
Enable (EN#)
Short pin on connector will enable the outputs when the mating pin is grounded. Supply will not power up until this pin is engaged
to its mate in the backplane. Unit output will be inhibited as pin is disengaged from the mating connector.
Output Inhibit (INH#)
Secondary referenced; active low, TTL compatible. Logic “0” or short circuit to output return inhibits all outputs.
Output Fault (FAL#)
Secondary referenced; TTL compatible. Logic “0” denotes that one of the output voltages has fallen below the lower regulation limit.
Remote Sense (RS+, RS-)
Connection of the sense leads across the load at the desired point of regulation will compensate for voltage distribution drops up to 250mV
between the output terminals of the power supply and the point of connection. The output is protected against shorted or open leads. Each
of the Remote Sense lines must be terminated to the corresponding output and return lines in order guarantee all performance specifications.
Thermal Warning (DEG#)
Secondary referenced; TTL compatible. Logic “0” denotes a thermal warning; nominally, 10ºC prior to thermal shutdown.
Sync Start (Sync)
Interconnection of the sync start leads between cPCI200A-1 units connected in parallel permits synchronous starting to support loads
that exceed the maximum for a single unit. Pin 35 (V1 Share) is used for the synchronous start function.
Fault Indicator LED
An LED will illuminate red if the output voltages are not within specification, coincident with assertion of the FAL# signal. This LED
will also illuminate amber if the output is inhibited.
Power Present Indicator LED
A green LED will be illuminated when the input voltage is present and above the minimum requirement.
ENVIRONMENTAL CHARACTERISTICS
Parameter
Conditions
Ambient Operating Temperature
Ambient Storage Temperature
Operating Humidity
Non-condensing
Storage Humidity
Non-condensing
Altitude
Min
Max
Units
0
Typ
50
ºC
-40
125
ºC
10
90
%
5
90
%
Operating. De-rate operating ambient temperature by 2Cº per 1000ft above 5000ft.
-200
10000
ft
Storage
-200
50000
ft
www.murata-ps.com/support
cPCI200A-1C Series.E01 Page 2 of 4
cPCI200A-1C Series
200W 3Ux4HP AC/DC CompactPCI™
ELECTROMAGNETIC COMPATIBILITY (EMC)
Characteristic
Compliance
Input Current Harmonics
EN61000-3-2, Class A
Conducted Emissions
CFR Title 47, Part 15, Sub-part B, Class A
EN55022, Class A
Electrostatic Discharge (ESD)
EN61000-4-2, Level 3, Criterion B
Radiated Immunity
EN61000-4-3, Level 3
Conducted Immunity
EN61000-4-4, Level 3, Criterion A
Line Voltage Surge
EN61000-4-5, Level 2, Criterion B
Line Voltage Interruptions
EN61000-4-11
CERTIFICATIONS
Agency/Characteristic
Standard
UL
UL60950-1
CSA
CSA60950-1 (per cUL)
VDE
EN60950-1
CE
LVD Directive; self-certified
RoHS
EN Directive 2002/95/EC; self-certified (see Selection Guide for specific model compliances)
SELV
Certified
Vibration
MIL-STD-883F, Method 2007.3, Test Condition A, pending
Shock
MIL-STD-883F, Method 2002.4, Test Condition A, pending
SAFETY AGENCY RATINGS
Input Voltage
120/240Vac
Input Current
3A
Input Power
270W
MECHANICAL DIMENSIONS
www.murata-ps.com/support
cPCI200A-1C Series.E01 Page 3 of 4
cPCI200A-1C Series
200W 3Ux4HP AC/DC CompactPCI™
CONNECTOR
RoHS COMPLIANT INFORMATION
Pin Staging Signal Name Description
1-4
5-12
13-18
19
20
21
22
23
24
25
26
27
28
293
30
31
323
33
34
35
36
373
38
39
403
413
42
433
443
45
46
47
V1V1 Output
RTN V1 and V2 Return
V2V2 Output
RTNV3 Return
V3V3 Output
V4V4 Output
RTNSignal Return
RESERVEDReserved
RTNV4 Return
GA0 Geographic Address Bit 0
RESERVEDReserved
EN#Enable
GA1 Geographic Address Bit 1
V1ADJ V1 Adjust
V1 SENSE V1 Remote Sense
GA2 Geographic Address Bit 2
V2ADJ V2 Adjust
V2 SENSE V2 Remote Sense
S RTN Sense Return
V1 SHARE Sync Start
V3 SENSE V3 Remote Sense
IPMB SCL IPMB Serial Clock Line
DEG#Degrade Signal
INH#Inhibit
IPMB SDA IPMB Serial Data Line
V2 SHARE V2 Current Share
FAL#Fail Signal
IPMB PWR IPMB Power Input
V3 SHARE V3 Current Share
CGND Chassis Grnd (Safety Grnd)
ACN/+DC IN AC Input Neutral/+DC Input
ACL/-DC IN AC Input Line/-DC Input
1
Notes:
2
M
M
M
M
M
M
M
M
M
M
M
S
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
L
M
M
This series is compatible with RoHS soldering
systems with a peak wave solder temperature
of 300ºC for 10 seconds. The pin termination
finish on this product series is Tin Plate, Hot
Dipped over Matte Tin with Nickel Preplate.
The series is backward compatible with Sn/Pb
soldering systems.
For further information, please visit www.murata-ps.com/rohs
1. Pin numbers correspond to the female backpane connector.
2. “L” denotes long pin length (first mate, last break)
“M” denotes medium pin length
“S” denotes short pin length (last mate, first break)
3. This function not used in the CPCI200A-1C Series.
ISO9001
CERTIFIED
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice. © 2014 Murata Power Solutions, Inc.
www.murata-ps.com/support
cPCI200A-1C Series.E01 Page 4 of 4