Repetitive peak reverse voltage: VRRM = 600 V
Average forward current: IF (AV) = 1.0 A
Forward voltage: VFM = 2.0 V (max)
Very fast reverse-recovery time: trr = 100 ns (max.)
•
Suitable for compact assembly due to small surface-mount package
“M−FLATTM” (Toshiba package name)
Absolute Maximum Ratings (Ta = 25°C)
Characteristic
Symbol
Rating
Unit
Repetitive peak reverse voltage
VRRM
600
V
Average forward current
IF (AV)
1.0 (Note 1)
A
IFSM
10 (50 Hz)
(Note 3)
A
Tj
−40~150
°C
Tstg
−40~150
°C
Peak one-cycle surge forward current
(non-repetitive)
Junction temperature
Storage temperature range
Note 1: Tℓ = 108°C
Rectangular waveform (α = 180°)
JEDEC
⎯
JEITA
⎯
TOSHIBA
3-4E1A
Weight: 0.023 g (typ.)
Note 2: Using continuously under heavy loads (e.g. the application of
high temperature/current/voltage and the significant change in
temperature, etc.) may cause this product to decrease in the reliability significantly even if the operating
conditions (i.e. operating temperature/current/voltage, etc.) are within the absolute maximum ratings.
Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook
(“Handling Precautions”/Derating Concept and Methods) and individual reliability data (i.e. reliability test
report and estimated failure rate, etc).
Note 3: This rating specifies the non-repetitive peak current in one cycle of a 50 Hz sine wave, condition angle 180°.
Therefore the rating applies only to abnormal operation, which seldom occurs during the lifespan of a device.
1
2007-04-16
CMF02
Electrical Characteristics (Ta = 25°C)
Characteristic
Symbol
Test Condition
Min
Typ.
Max
Unit
Peak forward voltage
VFM
IFM = 1.0 A (pulse test)
⎯
⎯
2.0
V
Repetitive peak reverse current
IRRM
VRRM = 600 V (pulse test)
⎯
⎯
50
μA
Reverse recovery time
trr
IF = 1 A, di/dt =-30 A/μs
⎯
⎯
100
ns
Forward recovery time
tfr
IF = 1 A
⎯
270
⎯
ns
Device mounted on a ceramic board
(board size: 50 mm × 50 mm)
(soldering land: 2 mm × 2 mm)
(board thickness: 0.64 t)
⎯
⎯
60
Device mounted on a glass-epoxy
board
(board size: 50 mm × 50 mm)
(soldering land: 6 mm × 6 mm)
(board thickness: 1.6 t)
⎯
⎯
135
Device mounted on a glass-epoxy
board
(board size: 50 mm × 50 mm)
(soldering land: 2.1 mm × 1.4 mm)
(board thickness: 1.6 t)
⎯
⎯
210
⎯
⎯
16
Thermal resistance
Rth (j-a)
Thermal resistance (junction to lead)
⎯
Rth (j-ℓ)
Marking
°C/W
°C/W
Standard Soldering Pad
Part No.
F2
CMF02
Unit: mm
2.1
Abbreviation Code
1.4
3.0
1.4
Handling Precautions
Thermal resistance between junction and ambient fluctuates depending on the mounting condition of the device. When
using the device, be sure to design the circuit board and soldering land size to match the appropriate thermal resistance
value.
Refer to the Rectifier databook for further information.
2
2007-04-16
CMF02
iF – vF
PF (AV) – IF (AV)
3.0
Pulse test
Average forward power dissipation
PF (AV) (W)
Instantaneous forward current
iF (A)
10
Tj = 150°C
1
75°C
25°C
0.1
180°
120°
2.0
α = 60°
Rectangular
waveform
1.0
0° α 360°
Conduction angle α
0.01
0
1.0
2.0
3.0
4.0
Instantaneous forward voltage VF
0
0
5.0
0.2
0.4
0.6
Average forward current
(V)
0.8
1.0
IF (AV)
(A)
1.2
Ta max – IF (AV)
140
120
100
80
Rectangular
waveform
60
120°
40
0° α 360°
20
0
0
α = 60°
0.4
0.2
Conduction
angle: α
180°
0.6
Average forward current
0.8
1.0
IF (AV)
(A)
Tℓ max – IF (AV)
160
Maximum allowable lead temperature
Tℓ max (°C)
Maximum allowable ambient temperature
Ta max (°C)
160
Device mounted on a glass-epoxy board
(board size: 50 mm × 50 mm, land size: 6 mm × 6 mm)
140
120
100
80
40
0° α 360°
20
0
1.2
Rectangular
waveform
60
α = 60°
Conduction
angle: α
0
0.2
0.4
0.6
Average forward current
120°
180°
0.8
1.0
IF (AV)
(A)
1.2
Surge forward current
rth (j-a) – t
(non-repetitive)
1000
Ta = 25°C
f = 50 Hz
10
Transient thermal impedance
rth (j-a) (°C/W)
Peak surge forward current
IFSM (A)
12
8
6
4
2
0
1
3
5
10
30
50
Device mounted on
a glass-epoxy board
(board size: 50 mm × 50 mm,
land size: 2.1 mm × 1.4 mm,
board thickness: 1.6 t)
100
10
Device mounted on a ceramic board
(board size: 50 mm × 50 mm,
land size: 2 mm × 2 mm,
board thickness: 0.64 t)
1
0.001
100
Number of cycles
Device mounted on
a glass-epoxy board
(board size: 50 mm × 50 mm,
land size: 6 mm × 6 mm,
board thickness: 1.6 t)
0.01
0.1
1
10
100
1000
Time t (s)
3
2007-04-16
CMF02
RESTRICTIONS ON PRODUCT USE
20070701-EN
• The information contained herein is subject to change without notice.
• TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc.
• The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.).These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in his
document shall be made at the customer’s own risk.
• The products described in this document shall not be used or embedded to any downstream products of which
manufacture, use and/or sale are prohibited under any applicable laws and regulations.
• Please contact your sales representative for product-by-product details in this document regarding RoHS
compatibility. Please use these products in this document in compliance with all applicable laws and regulations
that regulate the inclusion or use of controlled substances. Toshiba assumes no liability for damage or losses
occurring as a result of noncompliance with applicable laws and regulations.
4
2007-04-16