TOSHIBA VR4J

TVR4J,TVR4N
TOSHIBA Fast Recovery Diode Silicon Diffused Type
TVR4J,TVR4N
High Speed Rectifier Applications (fast recovery)
·
Unit: mm
Repetitive Peak Reverse Voltage: VRRM = 600, 1000 V
·
Average Forward Current: IF (AV) = 1.2 A (Ta = 55°C)
·
Reverse Recovery Time: trr = 20 µs
·
Plastic Mold Type.
Maximum Ratings (Ta = 25°C)
Characteristics
TVR4J
Repetitive peak
reverse voltage
TVR4N
Symbol
VRRM
Rating
Unit
600
V
1000
Average forward current (Ta = 55°C )
IF (AV)
1.2
A
Peak one cycle surge forward current
(non repetitive)
IFSM
100 (50 Hz)
A
Tj
-40 to 150
°C
JEDEC
―
Tstg
-40 to 150
°C
JEITA
―
Junction temperature
Storage temperature range
TOSHIBA
Electrical Characteristics (Ta = 25°C)
Characteristics
3-4B1A
Weight: 0.47 g (typ.)
Symbol
Test Condition
Min
Typ.
Max
Unit
Peak forward voltage
VFM
IFM = 5 A
¾
¾
1.2
V
Repetitive peak reverse current
IRRM
VRRM = Rated
¾
¾
10
mA
IF = 20 mA, IR = 1 mA
¾
¾
20
ms
DC
¾
¾
80
°C/W
Reverse recovery time
Thermal resistance (junction to ambient)
trr
Rth (j-a)
Note1: Soldering: 5 mm is the minimum to be kept between case and soldering part.
Note2: Lead bending: 5 mm is the minimum to be kept from the case when bend the lead wire.
Marking
VR
4J
Type Code Lot No.
Month (starting from alphabet A)
Year (last number of the christian era)
Code
Type
VR4J
TVR4J
VR4N
TVR4N
Cathode Mark
Color: Silver
1
2002-09-18
TVR4J,TVR4N
iF – vF
rth (j-a) – t
30
Transient thermal impedance
rth (j-a) (°C /W)
10
5
Tj = 25°C
150
3
1
0.5
0.2
0.4
0.6
0.8
1.0
1.2
1.4
Instantaneous forward voltage
1.6
vF
1.8
10
1
0.1
0.01
0.0001
2.0
0.001
0.01
1
10
100
Time t (s)
(V)
Surge forward current (non-repetitive)
Ta max – IF (AV)
160
Maximum allowable temperature
Ta max (°C)
f = 50 Hz
80
60
40
20
140
3
5
10
30
Number of cycles
5 mm
120
①
②
100
80 ①
a
③
Solder land
60 ②
a
Solder land
④
20 ´ 20 mm
40 ③
a
Sine wave
30 ´ 30 mm
0
0
100
5 mm
a
20
0
1
a ´ a: solder land
Resistive and
inductive load
Tj = 25°C
5 mm
(A)
100
Peak surge forward current IFSM
0.1
5 mm
Instantaneous forward current
iF
(A)
Ta = 25°C
100
Solder land
10 ´ 10 mm
④
Solder land
less full lead
0.2
0.4
0.6
0.8
1.0
1.2
Average forward current
1.4
IF (AV)
1.6
1.8
2.0
(A)
Ta max – IF (AV)
160
a ´ a: solder land
5 mm
a
5 mm
①
120
5 mm
Maximum allowable temperature
Ta max (°C)
Capacitive load
140
a
100
②
③
80
Sine wave
④
①
60
②
40
③
20
④
0
0
0.2
0.4
0.6
a
a
Solder land
30 ´ 30 mm
Solder land
20 ´ 20 mm
Solder land
10 ´ 10 mm
Solder land
less full lead
0.8
Average forward current
IF (AV)
(A)
2
2002-09-18
TVR4J,TVR4N
RESTRICTIONS ON PRODUCT USE
000707EAA
· TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc..
· The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this
document shall be made at the customer’s own risk.
· The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other
rights of the third parties which may result from its use. No license is granted by implication or otherwise under
any intellectual property or other rights of TOSHIBA CORPORATION or others.
· The information contained herein is subject to change without notice.
3