TOSHIBA DF5A68FU

DF5A6.8FU
TOSHIBA Diodes for Protecting against ESD
Epitaxial Planar Type
DF5A6.8FU
Diodes for Protecting against ESD
Unit: mm
The mounting of two devices on an ultra-compact package allows the
number of parts and the mounting cost to be reduced.
The zener voltage corresponds to the E24 Series.
Maximum Ratings (Ta = 25°C)
Characteristic
Symbol
Rating
Unit
Power dissipation
P
200
mW
Junction temperature
Tj
125
°C
Tstg
−55~125
°C
Storage temperature range
―
JEDEC
―
JEITA
1-2V1B
TOSHIBA
Weight: 0.0062 g (typ.)
Electrical Characteristics (Ta = 25°C)
Characteristic
Symbol
Zener voltage
VZ
Test Condition
Min
Typ.
Max
Unit
IZ = 5 mA
6.4
6.8
7.2
V
Dynamic impedance
ZZ
IZ = 5 mA
―
10
25
Ω
Knee dynamic impedance
ZZK
IZ = 0.5 mA
―
30
―
Ω
Reverse current
IR
VR = 5 V
―
―
0.5
µA
Terminal capacitance
(between Cathode and Anode)
CT
VR = 0, f = 1 MHz
―
45
―
pF
Guaranteed Level of ESD Immunity
Test Condition
ESD Immunity Level
IEC61000-4-2
(Contact discharge)
±30kV
Criterion: No damage to device elements
Marking
Equivalent Circuit (Top View)
1
2004-11-08
DF5A6.8FU
CT - VR
100
TOTAL CAPACITANCE CT (pF)
Ta=25°C
f=1MHz
10
0
2
4
6
REVERSE VOLTAGE VR (V)
8
2
2004-11-08
DF5A6.8FU
RESTRICTIONS ON PRODUCT USE
030619EAA
• The information contained herein is subject to change without notice.
• The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which
may result from its use. No license is granted by implication or otherwise under any patent or patent rights of
TOSHIBA or others.
• TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc..
• The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this
document shall be made at the customer’s own risk.
• TOSHIBA products should not be embedded to the downstream products which are prohibited to be produced
and sold, under any law and regulations.
3
2004-11-08