TOSHIBA TLP3022S

TLP3021(S),TLP3022(S),TLP3023(S)
TOSHIBA PHOTOCOUPLER GaAs IRED & PHOTO-TRIAC
TLP3021(S),TLP3022(S),TLP3023(S)
Unit: mm
OFFICE MACHINE
HOUSEHOLD USE EQUIPMENT
TRIAC DRIVER
SOLID STATE RELAY
The TOSHIBA TLP3021 (S), TLP3022 (S) and TLP3023 (S) consist of
photo-triac optically coupled to a gallium arsenide infrared emitting diode
in a six lead plastic DIP.
z Peak Off-State Voltage
: 400 V (min)
z Trigger LED Current
: 15 mA (max) (TLP3021(S))
10 mA (max) (TLP3022(S))
5 mA (max) (TLP3023(S))
z On-State Current
: 100 mA (max)
z Isolation Voltage
: 5000Vrms(Min)
z UL Recognized
: UL1577,File No.E67349
z SEMKO Approved
: SS EN60065
SS EN60950, File No.9841105
z BSI Approved
: BS EN60065, File No.8385
JEDEC
EIAJ
TOSHIBA
Weight : 0.39g
―
―
11-7A9
BS EN60950, File No.8386
z Option (D4) type
VDE approved: DIN EN60747-5-2
Pin Configuration
(top view)
Approved No. 40009302
Maximum operating insulation voltage: 890VPK
1
Highest permissible over voltage: 8000VPK
(Note):When a EN60747-5-2 approved type is needed,
please designate the "Option (D4)"
z Construction Mechanical Rating
Creepage Distance
Clearance
Insulation Thickness
7.62 mm pich
Standard Type
10.16 mm pich
TLPxxxxF Type
7.0 mm (Min)
7.0 mm (Min)
0.5 mm (Min)
8.0 mm (Min)
8.0 mm (Min)
0.5 mm (Min)
1
6
2
4
3
1: Anode
2: Csthode
3: N.C.
4:Terminal 1
6:Terminal 2
2007-10-01
TLP3021(S),TLP3022(S),TLP3023(S)
Absolute Maximum Ratings (Ta=25°C)
CHARACTERISTIC
SYMBOL
RATING
UNIT
IF
50
mA
∆IF /°C
−0.7
mA /°C
Peak Forward Current (100μs pulse, 100pps)
IFP
1
A
Power Dissipation
PD
100
mW
∆PD /°C
-1.0
mW/°C
Reverse Voltage
VR
5
V
Junction Temperature
Tj
125
°C
VDRM
400
V
Forward Current
LED
Forward Current Derating (Ta≥53°C)
Power Dissipation Derating (Ta≥25°C)
Off-State Output Terminal Voltage
Ta=25°C
On-State RMS Current
100
IT(RMS)
DETECTOR
mA
50
Ta=70°C
On-State Current Derating (Ta≥25°C)
∆IT/°C
-1.1
mA /°C
Peak On-State Current (100μs pulse, 120pps)
ITP
2
A
Peak Nonrepetitive Surge Current
ITSM
1.2
A
PD
300
mW
∆PD /°C
-4.0
mW/°C
Tj
115
°C
Storage Temperature Range
Tstg
−55~150
°C
Operating Temperature Range
Topr
−40~100
°C
Lead Soldering Temperature (10s)
Tsol
260
°C
PT
330
mW
∆PT/°C
-4.4
mW /°C
BVS
5000
Vrms
(Pw=10ms,DC=10%)
Power Dissipation
Power Dissipation Derating (Ta≥25°C)
Junction Temperature
Total Package Power Dissipation
Total Package Power Dissipation Derating (Ta≥25°C)
Isolation Voltage (AC,1min. , R.H.≤60%)
(Note 2)
Note: Using continuously under heavy loads (e.g. the application of high temperature/current/voltage and the
significant change in temperature, etc.) may cause this product to decrease in the reliability significantly even
if the operating conditions (i.e. operating temperature/current/voltage, etc.) are within the absolute maximum
ratings.
Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook
(“Handling Precautions”/“Derating Concept and Methods”) and individual reliability data (i.e. reliability test
report and estimated failure rate, etc).
(Note 2)
Device considered a two terminal device :Pins1,2 and 3 shorted together and pin4 and pin6 shorted
together.
Recommended Operating Conditions
CHARACTERISTIC
Supply Voltage
SYMBOL
MIN.
TYP.
MAX.
UNIT
VAC
—
—
120
Vac
*
Forward Current
IF
15
20
25
mA
Peak On-State Current
ITP
—
—
1
A
Operating Temperature
Topr
−25
—
85
°C
Note: Recommended operating conditions are given as a design guideline to obtain expected performance of the
device. Additionally, each item is an independent guideline respectively. In developing designs using this
product, please confirm specified characteristics shown in this document.
*In The case of TLP3022
2
2007-10-01
TLP3021(S),TLP3022(S),TLP3023(S)
Individual Electrical Characteristics (Ta=25°C)
LED
CHARACTERISTIC
SYMBOL
MIN.
TYP.
MAX.
UNIT
Forward Voltage
VF
IF = 10 mA
1.0
1.15
1.3
V
Reverse Current
IR
VR = 5 V
—
—
10
μA
V = 0, f=1MHz
—
10
—
pF
Capacitance
D E T E C T O R
TEST CONDITION
CT
Peak Off-State Current
IDRM
VDRM=400V
—
10
1000
nA
Peak On-State Voltage
VTM
ITM=100mA
—
1.7
3.0
V
—
0.6
—
mA
Holding Current
IH
Critical Rate of Rise of
Off-State Voltage
Critical Rate of Rise of
Commutating Voltage
—
dv/dt
Vin=120Vrms , Ta=85°C
(Fig.1)
200
500
—
V/μs
dv/dt(c)
Vin=30Vrms , IT=15mA
(Fig.1)
—
0.2
—
V/μs
MIN.
TYP.
MAX.
UNIT
—
—
15
—
5
10
—
—
5
0.8
—
pF
—
Ω
Coupled Electrical Characteristics (Ta=25°C)
CHARACTERISTIC
SYMBOL
TEST CONDITION
TLP3021(S)
Trigger LED Current
IFT
TLP3022(S)
VT=3V
TLP3023(S)
Capacitance (Input to Output)
CS
Isolation Resistance
RS
VS=500V(R.H.≤60%)
Fig. 1
BVS
5×10
10
10
14
5000
—
—
AC , 1second,in oil
—
10000
—
DC , 1minute,in oil
—
10000
—
AC , 1minute
Isolation Voltage
—
VS=0 , f=1MHz
mA
Vrms
Vdc
dv / dt test circuit
+
VCC
Rin
120Ω
−
1
2
3
4
+5V,VCC
Vin
6
RL
0V
~
dv / dt(c)
2kΩ
3
dv / dt
2007-10-01
TLP3021(S),TLP3022(S),TLP3023(S)
4
2007-10-01
TLP3021(S),TLP3022(S),TLP3023(S)
5
2007-10-01
TLP3021(S),TLP3022(S),TLP3023(S)
RESTRICTIONS ON PRODUCT USE
20070701-EN
• The information contained herein is subject to change without notice.
• TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc.
• The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.).These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in his
document shall be made at the customer’s own risk.
• The products described in this document shall not be used or embedded to any downstream products of which
manufacture, use and/or sale are prohibited under any applicable laws and regulations.
• The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which
may result from its use. No license is granted by implication or otherwise under any patents or other rights of
TOSHIBA or the third parties.
• GaAs(Gallium Arsenide) is used in this product. The dust or vapor is harmful to the human body. Do not break,
cut, crush or dissolve chemically.
• Please contact your sales representative for product-by-product details in this document regarding RoHS
compatibility. Please use these products in this document in compliance with all applicable laws and regulations
that regulate the inclusion or use of controlled substances. Toshiba assumes no liability for damage or losses
occurring as a result of noncompliance with applicable laws and regulations.
6
2007-10-01