30EPF..PbF, 30CPF..PbF Soft Recovery Series Vishay High Power Products Fast Soft Recovery Rectifier Diode, 30 A 30EPF.. FEATURES/DESCRIPTION 30CPF.. The 30EPF..PbF and 30CPF..PbF soft recovery rectifier series has been optimized for combined short reverse recovery time and low forward voltage drop. Base common cathode 2 The glass passivation ensures stable reliable operation in the most severe temperature and power cycling conditions. Base common cathode 2 30CPF series is a drop in replacement for 25CPF series (parallel connection only). This product series has been designed and qualified for industrial level. 1 Cathode 3 Anode Anode 1 Compliant to RoHS directive 2002/95/EC. Anode 3 APPLICATIONS TO-247AC modified TO-247AC • Output rectification and choppers and converters PRODUCT SUMMARY freewheeling • Input rectifications where severe conducted EMI should be met VF at 10 A < 1.2 V trr 60 ns VRRM 200 V to 600 V in inverters, restrictions on MAJOR RATINGS AND CHARACTERISTICS SYMBOL IF(AV) CHARACTERISTICS Sinusoidal waveform VALUES UNITS 30 A VRRM 200 to 600 V IFSM 350 A VF 10 A, TJ = 25 °C 1.2 V trr 1 A, 100 A/μs 60 ns - 40 to 150 °C TJ VOLTAGE RATINGS VRRM, MAXIMUM PEAK REVERSE VOLTAGE V VRSM, MAXIMUM NON-REPETITIVE PEAK REVERSE VOLTAGE V 30EPF02PbF, 30CPF02PbF 200 300 30EPF04PbF, 30CPF04PbF 400 500 30EPF06PbF, 30CPF06PbF 600 700 PART NUMBER IRRM AT 150 °C mA 2 ABSOLUTE MAXIMUM RATINGS PARAMETER SYMBOL TEST CONDITIONS VALUES Maximum average forward current IF(AV) TC = 98 °C, 180° conduction half sine wave 30 Maximum peak one cycle non-repetitive surge current IFSM Maximum I2t for fusing I2t Maximum I2√t for fusing I2√t 10 ms sine pulse, rated VRRM applied 300 10 ms sine pulse, no voltage reapplied 350 10 ms sine pulse, rated VRRM applied 450 10 ms sine pulse, no voltage reapplied 636 t = 0.1 ms to 10 ms, no voltage reapplied 6360 UNITS A A2s A2√s * Pb containing terminations are not RoHS compliant, exemptions may apply Document Number: 94100 Revision: 09-Dec-09 For technical questions, contact: [email protected] www.vishay.com 1 30EPF..PbF, 30CPF..PbF Soft Recovery Series Vishay High Power Products Fast Soft Recovery Rectifier Diode, 30 A ELECTRICAL SPECIFICATIONS PARAMETER SYMBOL Maximum forward voltage drop Forward slope resistance VFM rt Threshold voltage VF(TO) Maximum reverse leakage current IRM TEST CONDITIONS VALUES 30 A, TJ = 25 °C TJ = 150 °C TJ = 25 °C 1.41 V 12.5 mΩ 0.9 V 0.1 VR = Rated VRRM TJ = 150 °C UNITS mA 2.0 RECOVERY CHARACTERISTICS PARAMETER SYMBOL Reverse recovery time trr Reverse recovery current Irr Reverse recovery charge Qrr Snap factor S TEST CONDITIONS VALUES UNITS IF at 20 Apk 160 ns 100 A/μs 25 °C 10 A 1.25 μC Typical IFM trr ta tb t dir dt 0.6 Qrr IRM(REC) THERMAL - MECHANICAL SPECIFICATIONS PARAMETER SYMBOL Maximum junction and storage temperature range TEST CONDITIONS TJ, TStg Maximum thermal resistance, junction to case RthJC Maximum thermal resistance, junction to ambient RthJA Maximum thermal resistance, case to heatsink RthCS DC operation UNITS - 40 to 150 °C 0.8 40 Mounting surface, smooth and greased °C/W 0.2 6 g 0.21 oz. minimum 6 (5) maximum 12 (10) kgf · cm (lbf · in) Approximate weight Mounting torque VALUES 30EPS02, 30CPF02 Marking device Case style TO-247AC modified (JEDEC) 30EPS04, 30CPF04 30EPS06, 30CPF06 www.vishay.com 2 For technical questions, contact: [email protected] Document Number: 94100 Revision: 09-Dec-09 30EPF..PbF, 30CPF..PbF Soft Recovery Series Fast Soft Recovery Rectifier Diode, 30 A 45 30.PF.. Series RthJC (DC) = 0.8 K/W 140 Maximum Average Forward Power Loss (W) Maximum Allowable Case Temperature (°C) 150 130 Ø Conduction angle 120 110 30° 60° 100 90° 120° 180° 5 0 15 10 20 25 30 35 30 DC 25 20 RMS limit 15 Ø Conduction period 10 30.PF.. Series TJ = 150 °C 5 35 0 5 10 20 15 25 30 35 Average Forward Current (A) Average Forward Current (A) Fig. 1 - Current Rating Characteristics Fig. 4 - Forward Power Loss Characteristics 350 150 30.PF.. Series RthJC (DC) = 0.8 K/W 140 130 Ø Conduction period 120 30° 110 60° 90° 100 At any rated load condition and with rated VRRM applied following surge. 300 Peak Half Sine Wave Forward Current (A) Maximum Allowable Case Temperature (°C) 180° 120° 90° 60° 30° 40 0 90 Initial TJ = 150 °C at 60 Hz 0.0083 s at 50 Hz 0.0100 s 250 200 150 100 120° 30.PF.. Series DC 180° 50 90 0 5 10 15 20 25 30 35 40 45 50 1 10 100 Number of Equal Amplitude Half Cycle Current Pulses (N) Fig. 5 - Maximum Non-Repetitive Surge Current Average Forward Current (A) Fig. 2 - Current Rating Characteristics 35 400 180° 120° 90° 60° 30° 30 25 350 Peak Half Sine Wave Forward Current (A) Maximum Average Forward Power Loss (W) Vishay High Power Products RMS limit 20 15 Ø 10 Conduction angle 5 30.PF.. Series TJ = 150 °C 5 10 15 20 Initial TJ = 150 °C No voltage reapplied Rated VRRM reapplied 300 250 200 150 100 50 30.PF.. Series 0 0 Maximum non-repetitive surge current versus pulse train duration. 25 0 0.01 0.1 1 10 Average Forward Current (A) Pulse Train Duration (s) Fig. 3 - Forward Power Loss Characteristics Fig. 6 - Maximum Non-Repetitive Surge Current Document Number: 94100 Revision: 09-Dec-09 For technical questions, contact: [email protected] www.vishay.com 3 30EPF..PbF, 30CPF..PbF Soft Recovery Series Instantaneous Forward Current (A) Vishay High Power Products Fast Soft Recovery Rectifier Diode, 30 A 1000 100 TJ = 25 °C TJ = 150 °C 10 30.PF.. Series 1 0 1 2 3 4 5 Instantaneous Forward Voltage (V) Fig. 7 - Forward Voltage Drop Characteristics trr - Maximum Reverse Recovery Time (µs) 30.PF.. Series TJ = 25 °C 0.15 4.0 IFM = 30 A IFM = 20 A IFM = 10 A IFM = 30 A IFM = 5 A IFM = 1 A 0.10 0.05 0 IFM = 20 A 3.0 2.5 2.0 IFM = 10 A 1.5 1.0 IFM = 5 A 0.5 IFM = 1 A 0 0 200 400 600 800 1000 0 200 400 800 600 1000 dI/dt - Rate of Fall of Forward Current (A/µs) dI/dt - Rate of Fall of Forward Current (A/µs) Fig. 8 - Recovery Time Characteristics, TJ = 25 °C Fig. 10 - Recovery Charge Characteristics, TJ = 25 °C 0.5 10 30.PF.. Series TJ = 150 °C 0.4 IFM = 30 A IFM = 20 A IFM = 10 A IFM = 5 A IFM = 1 A 0.3 0.2 30.PF.. Series TJ = 150 °C 9 Qrr - Maximum Reverse Recovery Charge (µC) trr - Maximum Reverse Recovery Time (µs) 30.PF.. Series TJ = 25 °C 3.5 Qrr - Maximum Reverse Recovery Charge (µC) 0.20 0.1 IFM = 30 A 8 7 IFM = 20 A 6 5 IFM = 10 A 4 3 IFM = 5 A 2 1 IFM = 1 A 0 0 0 200 400 600 800 1000 0 200 400 600 800 1000 dI/dt - Rate of Fall of Forward Current (A/µs) dI/dt - Rate of Fall of Forward Current (A/µs) Fig. 9 - Recovery Time Characteristics, TJ = 150 °C Fig. 11 - Recovery Charge Characteristics, TJ = 150 °C www.vishay.com 4 For technical questions, contact: [email protected] Document Number: 94100 Revision: 09-Dec-09 30EPF..PbF, 30CPF..PbF Soft Recovery Series Fast Soft Recovery Rectifier Diode, 30 A 70 100 30.PF.. Series TJ = 25 °C 30.PF.. Series TJ = 150 °C IFM = 30 A Irr - Maximum Reverse Recovery Current (A) 60 Irr - Maximum Reverse Recovery Current (A) Vishay High Power Products IFM = 20 A 50 40 IFM = 10 A 30 IFM = 5 A 20 IFM = 1 A 10 IFM = 30 A 80 IFM = 20 A 60 IFM = 10 A 40 IFM = 5 A 20 IFM = 1 A 0 0 0 200 400 600 800 1000 0 200 400 600 800 1000 dI/dt - Rate of Fall of Forward Current (A/µs) Fig. 12 - Recovery Current Characteristics, TJ = 25 °C Fig. 13 - Recovery Current Characteristics, TJ = 150 °C ZthJC - Transient Thermal Impedance (K/W) dI/dt - Rate of Fall of Forward Current (A/µs) 10 1 D = 0.50 D = 0.33 D = 0.25 D = 0.17 D = 0.08 Steady state value (DC operation) 0.1 30.PF.. Series Single pulse 0.01 0.0001 0.001 0.01 0.1 1 Square Wave Pulse Duration (s) Fig. 14 - Thermal Impedance ZthJC Characteristics Document Number: 94100 Revision: 09-Dec-09 For technical questions, contact: [email protected] www.vishay.com 5 30EPF..PbF, 30CPF..PbF Soft Recovery Series Fast Soft Recovery Rectifier Diode, 30 A Vishay High Power Products ORDERING INFORMATION TABLE Device code 30 E P F 06 PbF 1 2 3 4 5 6 1 - 2 - Current rating (30 = 30 A) Circuit configuration: E = Single diode C = Single diode, 3 pins 3 - 4 - Package: P = TO-247AC (modified) Type of silicon: F = Fast recovery 5 - 6 - Voltage code x 100 = VRRM None = Standard production 02 = 200 V 04 = 400 V 06 = 600 V PbF = Lead (Pb)-free LINKS TO RELATED DOCUMENTS Dimensions Part marking information www.vishay.com 6 TO-247AC modified www.vishay.com/doc?95253 TO-247AC www.vishay.com/doc?95223 TO-247AC modified www.vishay.com/doc?95255 TO-247AC www.vishay.com/doc?95226 For technical questions, contact: [email protected] Document Number: 94100 Revision: 09-Dec-09 Legal Disclaimer Notice Vishay Disclaimer All product specifications and data are subject to change without notice. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product. Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any information provided herein to the maximum extent permitted by law. The product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein, which apply to these products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. Product names and markings noted herein may be trademarks of their respective owners. Document Number: 91000 Revision: 18-Jul-08 www.vishay.com 1