HRS DF21-30P

NEW
0.6mm Pitch Board-to-Fine-Coaxial Cable Connectors
DF21 Series
(7)
Pull-out tab
DF21*P/DP-0.6PTB
(4.55)
DF21-*P-0.6SD Plug
+DF21-*P-0.6SD-GND
1.55mm
Contact wipe
DF21-*S-0.6V
PCB
Receptacle
■Features
1.High Interconnection Reliability
Effective contact mating length of 1.55 mm, innovative bellow style contact design, built-in interlocking feature of
mated connectors assures high electrical and mechanical reliability, providing needed rigidity to resist
excessive twisting.
Superior reliability of the termination of the fine coaxial cable is accomplished with batch soldering.
2. Shielded design
Metal shell encloses the connector and makes contact with all external conductors of the fine coaxial cable
permitting reliable ground connection to the board side of mated assemblies.
3. Reliable mating/unmating
The connectors are self-align during mating.
Optional pull-out tab permits connection and disconnection in narrow spaces.
Polarized configuration prevents incorrect mating.
4. Board placement with Automatic Equipment.
The upper surface provides flat area for placement of embossed tape packaged connectors with vacuum
nozzles of automatic equipment.
■Applications
Notebook computers, liquid crystal displays (LCD), video and
audio devices, medical instruments, portable devices and
any other device requiring reliable connection and
termination with fine pitch coaxial cable.
Receptacle
Flat surface
for placement
with Automatic
Equipment
Metal Hold-down
2002.11
1
■Product Specifications
Operating temperature range
Ratings
Current rating
AWG #40: 0.3 A
AWG #36: 0.5 A
Wire size
Voltage rating
20% to 80%
Operating humidity range
50 V AC
Item
-35ç to 85ç (Note 1)
Storage temperature range
-10ç to 60ç (Note 2)
Storage humidity range
40% to 70% (Note 2)
Specifications
Condition
1. Insulation resistance
2. Withstanding voltage
3. Contact resistance
500M ohms min.
No flashover or insulation breakdown
100m ohms max.
Measured at 100 V DC
Conduction of 150 V AC applied for 1 minute
Measured at 100 mA
4. Vibration
No electrical discontinuity of 1µs or more.
Frequency of 10 to 55 Hz, single amplitude of 0.75 mm, in 3
directions, 2 hours
5. Humidity
Contact resistance of 100m ohms max., insulation
resistance of 50 M ohms min.
Temperature of 40±2ç, humidity of 90% to 95%, left standing
for 96 hours
6. Temperature cycle
Contact resistance of 100m ohms max., insulation
resistance of 50 M ohms min.
(-55ç : 30minutes /5 to 35ç : 2 to 3minutes /85ç : 30minutes
/5 to 35ç: 2 to 3minutes ) for 5 cycles
7. Durability
Contact resistance of 100m ohms max.
30 cycles (mating/unmating)
8. Resistance to
Reflow heat
No melting of the resin parts that will affect performance
Reflow: at the recommended temperature profile, Solder: at a
soldering iron temperature of 300ç for 3 seconds
9. Resistance to
Soldering heat
No deformation of the insulator parts affecting performance.
Solder bond: Within 5 seconds at 270ç max., Within 30 seconds at 200ç
min. Hand soldering: Soldering iron temperature 300°C, 3 seconds
Note 1: Includes temperature rise caused by current flow.
Note 2: The term “storage” refers to products stored for long period of time prior to mounting and use. Operating Temperature Range
and Humidity range covers non- conducting condition of installed connectors in storage, shipment or during transportation.
■Materials
Item
Part
Insulator
LCP
Black
UL94V-0
Receptacles
Contacts
Phosphor bronze
Gold plating
----------
Metal fittings
Phosphor bronze
Solder plating
----------
Insulator
LCP
Black
UL94V-0
Finish
Contacts
Phosphor bronze
Gold plating
----------
Phosphor bronze
Solder plating
----------
Pull-out tab
Stainless steel
----------
----------
■Ordering information
●Receptacles/Plug
DF 21 - * P - 0.6 SD - GND
1
2
1 Series name
: DF21
2 Number of contacts
: 20, 30, 40
3
3 Connector type
S : Single-row receptacle
P : Single-row plug
4 Contact pitch
2
Remarks
Metal shell
Plugs
Pull-out tab
Material
: 0.6 mm
4
5
6
5 Termination section
C : Crimping plug
V : Straight SMT
SD : Fine coaxial cable
6 Plug mounting parts
GND : Metal shell-required
PTB : Pull-out tab-optional
■Receptacles
3.8
3.2
0.2
A
B
3
0.2
0.4
P=0.6
P=0.6
●Embossed Carrier Tape Dimensions
.5
+1
.5
0
4±0.1
1.75±0.1
2±0.1
12±0.1
Ø1
t=0.4±0.1
2±0.5
(Ø80)
0.2
Ø21±
0.8
Ø330±2
Ø13±
E±0.3
D±0.1
C±0.1
Product
name
label
(E+0.4) +20
3.8
(E+6.4)MAX
Unreeling direction
[Specifications number] - * *, (* *)
(51) : Embossed tape packaging (1,000 pieces per reel)
Unit: mm
Product No.
CL No.
Number of Contacts
A
B
C
D
E
F
DF21-20S-0.6V(51)
687-0001-5-51
20
15.2
11.4
11.5
24
12.6
DF21-30S-0.6V(51)
687-0003-0-51
30
21.2
17.4
14.2
28.4
32
18.6
DF21-40S-0.6V(51)
687-0002-8-51
40
27.2
23.4
20.2
40.4
44
24.6
(Note 1)
Note : One reel contains 1,000 pieces package unit. Please order by the package unit.
●Recommended PCB mounting pattern
B±0.03
0.35±0.02
F±0.05
2.6±0.05
1.6 +0.10
2.3±0.05
1.3 +0.10
P=0.6±0.03
3
■Plugs
A
B
6.8
P=0.6
4.45
Shown with optional
Pull-out Tab
Unit: mm
Product No.
CL No.
Number of Contacts
A
B
C
DF21-20P-0.6SD
687-1500-0
20
22.5
11.4
15
DF21-30P-0.6SD
687-1502-6
30
28.5
17.4
21
DF21-40P-0.6SD
687-1501-3
40
34.5
23.4
27
Note 1: The 40 contact type is being planned.
Note 2: One package unit contains 100 pieces. Please order by the package unit.
●Recommended Fine Coaxial Cable Preparation
C±0.5
B±0.15
Pitch maintaining
tape
Inner conductor
(Solder coating required)
0.4max
4.1MAX
Ground bar
Insulator
Outer shield
(for individual conductor)
Fine coaxial cable
Note
Note
Note
Note
4
1:
2:
2:
3:
00.0
0.55 -0.05
1.1MIN
1.0 +0.10
-0.05
2.75MIN
1.1
0
-0.3
P=0.6±0.1
C±0.3
Jacket
The pitch maintaining tape can be left in place during the termination process. Use high quality tape.
When using 2-conductor coaxial cable, some contact positions will not be usable.
Contact nearest Hirose sales office for recommendation on specific application.
Contact Hirose for Termination Procedures.
■Metal shell-Required for assembly of the Plug
1.75
A
t=0.2
7
Unit: mm
Product No.
CL No.
Number of Contacts
A
DF21-20P-0.6SD-GND
687-2500-6
20
17.7
DF21-30P-0.6SD-GND
687-2502-1
30
23.7
DF21-40P-0.6SD-GND
687-2501-9
40
29.7
Note 1: One package unit contains 100 pieces. Please order by the package unit.
Note 2: The metal shell is an absolutely necessary part at the time of wiring.
■Pull-out Tab (Optional for Plug)
Ø0.6
3.5
A
Unit: mm
Product No.
CL No.
Number of Contacts
A
DF21-20P/40DP-0.6PTB
687-1700-0
20
20.9
DF21-30P/60DP-0.6PTB
687-1701-2
30
26.9
DF21-40P/80DP-0.6PTB
687-1702-5
40
32.9
Note: One package unit contains 100 pieces. Please order by the package unit.
5
BUsage Recommendations
1. Recommended
Temperature Profile
IR re-flow
Preheating : 150ç for 30 to 90 sec.
Soldering : 235ç±5ç for 10 sec max.
220çmin. for 10 to 20 sec.
Temperature
250ç
240ç max.
220ç
200ç
150ç
100ç
Preheating
Soldering
50ç
0ç
0s
50 s
90 s
150 s
Time
Note 1: Up to 2 cycles of reflow soldering are possible under the same conditions, provided that
there is a return to normal temperature between the first and second cycle.
Note 2: The temperature profile indicates the board surface temperature at the point of contacts
with the connector terminals (for surface mounted plug assembly).
1. Recommended
Soldering temperature: 290ç ±10ç, Soldering time: within 2 sec.
2. Receptacle Recommended
Soldering temperature: 290ç ±10°C, soldering time: within 2 sec.
Manual Soldering Conditions
3. Recommended Screen Thickness
0.15mm
4. Board Warping
Maximum of 0.03 mm at the connector center section, with both ends of the connector as reference points.
5. Cleaning Conditions
Refer to "Nylon Connector Use Handbook."
6. Plug Recommended
260ç ±5ç within 5 sec, 200ç min. within 25 sec.
Soldering Conditions
7. Handling and use
precautions
■DO NOT mate/un-mate non-terminated plugs with non-mounted receptacles.
This may lead to damage or deformation of the contacts.
■DO NOT touch the exposed contacts of the receptacle with bare fingers. This may leave non-conductive film,
cause corrosion or electrostatic discharge, affecting performance of the connectors or sensitive electronic
components.
■DO NOT apply flux to the contact terminals when hand soldering the receptacle to the board. Wicking of the
flux into the electrical contact areas may lead to connection failures.
6